Objective: This single-arm multisite trial investigates the efficacy of the Neurostyle Brain Exercise Therapy Towards Enhanced Recovery (nBETTER) system, an Electroencephalogram (EEG)-based Motor Imagery Brain-Computer Interface (MI-BCI) employing visual feedback, for upper-limb stroke rehabilitation, and the presence of EEG correlates of mental fatigue during BCI usage. Methods: Thirteen recruited stroke patients underwent thrice-weekly nBETTER therapy coupled with standard arm therapy over 6 weeks. Upper-extremity Fugl-Meyer Motor Assessment (FMA) scores were measured at baseline (Week 0), post-intervention (Week 6) and follow-ups (Weeks 12 and 24). In total, 11/13 patients (mean age 55.2 years old, mean post-stroke duration 333.7 days, mean baseline FMA 35.5) completed the study. Results: Significant FMA gains relative to baseline were observed at Weeks 6 and 24. Retrospectively comparing to the standard arm therapy (SAT) control group and BCI with haptic knob (BCI-HK) intervention group from a previous similar study, the SAT group had no significant gains whereas the BCI-HK group had significant gains at Weeks 6, 12 and 24. EEG analysis revealed significant positive correlations between relative beta power and BCI performance in the frontal and central brain regions, suggesting that mental fatigue may contribute to poorer BCI performance. Conclusion: nBETTER, an EEG-based MI-BCI employing only visual feedback, helps stroke survivors sustain short-term FMA improvement. Analysis of EEG relative beta power indicates that mental fatigue may be present. Significance: This study adds nBETTER to the growing literature of safe and effective stroke rehabilitation MI-BCI, and suggests an additional fatigue-monitoring role in future such BCI.
2 April 2020 in IEEE Transactions on Biomedical Engineering
Objective: This randomized controlled feasibility study investigates the ability for clinical application of the Brain-Computer Interface-based Soft Robotic Glove (BCI-SRG) incorporating activities of daily living (ADL)-oriented tasks for stroke rehabilitation. Methods: Eleven recruited chronic stroke patients were randomized into BCI-SRG or Soft Robotic Glove (SRG) group. Each group underwent 120-minute intervention per session comprising 30-minute standard arm therapy and 90-minute experimental therapy (BCI-SRG or SRG). To perform ADL tasks, BCI-SRG group used motor imagery-BCI and SRG, while SRG group used SRG without motor imagery-BCI. Both groups received 18 sessions of intervention over 6 weeks. Fugl-Meyer Motor Assessment (FMA) and Action Research Arm Test (ARAT) scores were measured at baseline (week 0), post- intervention (week 6), and follow-ups (week 12 and 24). In total, 10/11 patients completed the study with 5 in each group and 1 dropped out. Results: Though there were no significant intergroup differences for FMA and ARAT during 6-week intervention, the improvement of FMA and ARAT seemed to sustain beyond 6-week intervention for BCI-SRG group, as compared with SRG control. Incidentally, all BCI-SRG subjects reported a sense of vivid movement of the stroke-impaired upper limb and 3/5 had this phenomenon persisting beyond intervention while none of SRG did. Conclusion: BCI-SRG suggested probable trends of sustained functional improvements with peculiar kinesthetic experience outlasting active intervention in chronic stroke despite the dire need for large-scale investigations to verify statistical significance. Significance: Addition of BCI to soft robotic training for ADL-oriented stroke rehabilitation holds promise for sustained improvements as well as elicited perception of motor movements.
Motor imagery-based brain–computer interface (MI-BCI) has been proposed as a rehabilitation tool to facilitate motor recovery in stroke. However, the calibration of a BCI system is a time-consuming and fatiguing process for stroke patients, which leaves reduced time for actual therapeutic interaction. Studies have shown that passive movement (PM) (i.e., the execution of a movement by an external agency without any voluntary motions) and motor imagery (MI) (i.e., the mental rehearsal of a movement without any activation of the muscles) induce similar EEG patterns over the motor cortex. Since performing PM is less fatiguing for the patients, this paper investigates the effectiveness of calibrating MI-BCIs from PM for stroke subjects in terms of classification accuracy. For this purpose, a new adaptive algorithm called filter bank data space adaptation (FB-DSA) is proposed. The FB-DSA algorithm linearly transforms the band-pass-filtered MI data such that the distribution difference between the MI and PM data is minimized. The effectiveness of the proposed algorithm is evaluated by an offline study on data collected from 16 healthy subjects and 6 stroke patients. The results show that the proposed FB-DSA algorithm significantly improved the classification accuracies of the PM and MI calibrated models (p < 0.05). According to the obtained classification accuracies, the PM calibrated models that were adapted using the proposed FB-DSA algorithm outperformed the MI calibrated models by an average of 2.3 and 4.5 % for the healthy and stroke subjects respectively. In addition, our results suggest that the disparity between MI and PM could be stronger in the stroke patients compared to the healthy subjects, and there would be thus an increased need to use the proposed FB-DSA algorithm in BCI-based stroke rehabilitation calibrated from PM.
Detecting stress is important for improving human health and potential, because moderate levels of stress may motivate people towards better performance at cognitive tasks, while chronic stress exposure causes impaired performance and health risks. We propose a Brain–Computer Interface (BCI) system to detect stress in the context of high-pressure work environments. The BCI system includes an electroencephalogram (EEG) headband with dry electrodes and an electrocardiogram (ECG) chest belt. We collected EEG and ECG data from 40 participants during two stressful cognitive tasks: the Cognitive Vigilance Task (CVT), and the Multi-Modal Integration Task (MMIT) we designed. We also recorded self-reported stress levels using the Dundee Stress State Questionnaire (DSSQ). The DSSQ results indicated that performing the MMIT led to significant increases in stress, while performing the CVT did not. Subsequently, we trained two different models to classify stress from non-stress states, one using EEG features, and the other using heart rate variability (HRV) features extracted from the ECG. Our EEG-based model achieved an overall accuracy of 81.0% for MMIT and 77.2% for CVT. However, our HRV-based model only achieved 62.1% accuracy for CVT and 56.0% for MMIT. We conclude that EEG is an effective predictor of stress in the context of stressful cognitive tasks. Our proposed BCI system shows promise in evaluating mental stress in high-pressure work environments, particularly when utilizing an EEG-based BCI.
1 August 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
NeuroComm is a platform to develop real time brain computer interface (BCI) applications. This paper introduces the basic modules of this platform and discusses some implementation issues. With a user management module, our system is user friendly and suitable for multiple users. Also, with flexible configuration files and signal processing algorithm libraries, it is easier to integrate multiple BCI applications into one system. The NeuroComm platform also acts as a flexible tool for BCI research.