Akiko Haruyama

Dr. Akiko Haruyama

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2008 in The Open Dentistry Journal
Verified
Journal Article
Open access
PDF file
AKAtsushi Kameyama
Atsushi Kameyama
TNTaeko Nakazawa
Taeko Nakazawa
AHAkiko Haruyama
Akiko Haruyama
CHChikahiro Haruyama
Chikahiro Haruyama
MHMakoto Hosaka
Makoto Hosaka
YHYoshito Hirai
Yoshito Hirai
This study compared surface roughness and gloss produced by different finishing/polishing procedures for two resin composites, Clearfil AP-X (AP-X) and Estelite Σ (ES). A total of 70 composite discs (n=35 for each resin composite) were prepared and divided at random into seven finishing/polishing groups (n=5): glass-pressed control; using a super-fine-grit diamond bur (SF); using CompoMaster (CM) after SF-finishing (SF+CM); using White Point (WP) after SF-finishing (SF+WP); using CM after SF+WP-finishing (SF+WP+CM); using Stainbuster (SB) after SF-finishing (SF+SB); and using CM after SF+SB-finishing (SF+SB+CM). After the finishing/polishing procedures, average surface roughness ( R a ) and surface gloss (Gs(60 ° )) of all specimens were assessed with a surface profilometer and specimen gloss meter, respectively. Glass-pressed controls for both AP-X and ES composites showed the best surface finish in terms of both R a and Gs(60 ° ). SF-finishing produced the roughest surface and led to almost complete loss of gloss. While additional polishing with CM reduced R a and increased Gs(60 ° ), the additional finishing effect of WP or SB between SF-finishing and CM-polishing was not found for either AP-X or ES.

1 January 2013 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
AKAtsushi Kameyama
Atsushi Kameyama
AHAkiko Haruyama
Akiko Haruyama
MAMasako Asami
Masako Asami
TTToshiyuki Takahashi
Toshiyuki Takahashi
The purpose of this study was to determine any discrepancies in the outputs of five commercial dental radiometers and also to evaluate the accuracy of these devices using a laboratory‐grade spectroradiometer. The power densities of 12 different curing light sources were repeatedly measured for a total of five times using each radiometer in a random order. The emission spectra of all of the curing light sources were also measured using the spectroradiometer, and the integral value of each spectrum was calculated to determine the genuine power densities, which were then compared to the displayed power densities measured by the dental radiometers. The displayed values of power density were various and were dependent on the brand of radiometer, and this may be because each radiometer has a different wavelength sensitivity. These results cast doubt upon the accuracy of commercially available dental radiometers.

1 January 2017 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
TST Sugiyama
T Sugiyama
AKAtsushi Kameyama
Atsushi Kameyama
TET Enokuchi
T Enokuchi
AHAkiko Haruyama
Akiko Haruyama
ACAkihiko Chiba
Akihiko Chiba
TTT Takahashi
T Takahashi
This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles. Key words:CAD/CAM, professional dental prophylaxis, prophylactic paste, surface gloss, surface roughness.

1 January 2014 in The Bulletin of Tokyo Dental College
Verified
Journal Article
Open access
PDF file
AHAkiko Haruyama
Akiko Haruyama
AKAtsushi Kameyama
Atsushi Kameyama
CTChihiro Tatsuta
Chihiro Tatsuta
KIKurumi Ishii
Kurumi Ishii
TSToshiko Sugiyama
Toshiko Sugiyama
TTToshiyuki Takahashi
Toshiyuki Takahashi
The purpose of this study was to investigate the effect of type of rubber dam and application method on the moisture exclusion effect. The intraoral temperature and relative humidity were compared among various moisture exclusion appliances. Various dry field techniques were applied to 5 subjects and intraoral temperature and relative humidity measured 5 min after placing a digital hygro-thermometer in the mouth. The relative humidity was 100% in all subjects when moisture was excluded by means of cotton rolls alone. When only tooth 36 was exposed, relative humidity was significantly lower with latex, urethane, or 3-dimensional sheets than with cotton rolls alone, and was similar to the level of humidity in the room. When a local rubber dam was used, the relative humidity was significantly higher than the indoor humidity (p <0.05). No significant differences were noted in the intraoral temperature or relative humidity between exposure of 4 teeth and 1 tooth, but variation in the relative humidity was more marked in 4- than in 1-tooth exposure. The creation of an air vent did not influence the moisture exclusion effect. These results suggest that the rubber dam isolation technique excludes moisture to a level equivalent to the humidity in the room when only a single tooth is exposed, but the moisture exclusion effect may be inconsistent when several teeth are exposed.

5 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
AKAtsushi Kameyama
Atsushi Kameyama
ASAoi Saito
Aoi Saito
AHAkiko Haruyama
Akiko Haruyama
TKTomoaki Komada
Tomoaki Komada
SSSetsuko Sugiyama
Setsuko Sugiyama
Takashi MuramatsuTakashi Muramatsu
Takashi Muramatsu
This study aimed to examine the marginal seal between various commercial temporary restorative materials and exposed dentin/built-up composite. Sixty bovine incisors were cut above the cemento-enamel junction, and half of the dentin was removed to form a step, which was built up using flowable resin composite. The root canals were irrigated, filled with calcium hydroxide, and sealed using one of six temporary sealing materials (hydraulic temporary restorative material, temporary stopping material, zinc oxide eugenol cement, glass-ionomer cement, auto-cured resin-based temporary restorative material, and light-cured resin-based temporary restorative material) (n = 10 for each material). The samples were thermocycled 500 times and immersed in an aqueous solution of methylene blue. After 2 days, they were cut along the long axis of the tooth and the depth of dye penetration was measured at the dentin side and the built-up composite side. For the margins of the pre-endodontic resin composite build-up, the two resin-based temporary restorative materials showed excellent sealing. Hydraulic temporary restorative material had a moderate sealing effect, but the sealing effect of both zinc oxide eugenol cement and glass-ionomer cement was poorer.

17 June 2019 in Applied Adhesion Science
Verified
Journal Article
Open access
PDF file
AKAtsushi Kameyama
Atsushi Kameyama
AHAkiko Haruyama
Akiko Haruyama
HAHirokazu Abo
Hirokazu Abo
MKMasashi Kojima
Masashi Kojima
YNYuichi Nakazawa
Yuichi Nakazawa
TMTakashi Muramatsu
Takashi Muramatsu
The aim of this study was to evaluate the influence of solvent evaporation on the ultimate tensile strength (UTS) of commercial adhesives. Two 1-step (OptiBond All-In-One and G-Premio Bond) and two 2-step (Clearfil SE Protect, OptiBond XTR) adhesives were selected. Two bottles of each adhesive were opened and stored at 37 °C in a dry oven with silica gel shielded from light for 2 weeks (“Desiccated”). Two unopened bottles were stored at room temperature (“Original”). After 2 weeks, the adhesives were used to fill an hour-glass shaped, metallic matrix mold and light-cured. Samples were weighed, and then immersed in a 37 °C water bath for 1 h or 7 days. The UTS of each sample was then measured at a cross-head speed of 1 mm/min (n = 10). The UTS for the Clearfil SE Protect was higher in the “Original” than “Desiccated” samples (p < 0.05). For the OptiBond XTR, no significant difference was found between the ‘Original’ and ‘Desiccated’ samples (p > 0.05). Neither of the two “Original” 1-step samples could be hardened, even after light-curing, yet the ‘Desiccated’ OptiBond All-In-One samples obtained high UTS values. Both OptiBond All-In-One and Clearfil SE Protect had an increase in weight after the 7-day immersion in water. In conclusion, residual solvent reduces the mechanical strength of the adhesive. The hydrophilicity of the adhesive resin might also affect its mechanical strength.