Markus Schreiner

Dr. Markus Schreiner

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2019 in CARTILAGE
Verified
Journal Article
Open access
PDF file
MSMarkus Schreiner
Markus Schreiner
MRMarcus Raudner
Marcus Raudner
SMStefan Marlovits
Stefan Marlovits
KBKlaus Bohndorf
Klaus Bohndorf
MWMichael Weber
Michael Weber
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
Since the first introduction of the MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) score, significant progress has been made with regard to surgical treatment options for cartilage defects, as well as magnetic resonance imaging (MRI) of such defects. Thus, the aim of this study was to introduce the MOCART 2.0 knee score — an incremental update on the original MOCART score — that incorporates this progression. The volume of cartilage defect filling is now assessed in 25% increments, with hypertrophic filling of up to 150% receiving the same scoring as complete repair. Integration now assesses only the integration to neighboring native cartilage, and the severity of surface irregularities is assessed in reference to cartilage repair length rather than depth. The signal intensity of the repair tissue differentiates normal signal, minor abnormal, or severely abnormal signal alterations. The assessment of the variables “subchondral lamina,” “adhesions,” and “synovitis” was removed and the points were reallocated to the new variable “bony defect or bony overgrowth.” The variable “subchondral bone” was renamed to “subchondral changes” and assesses minor and severe edema-like marrow signal, as well as subchondral cysts or osteonecrosis-like signal. Overall, a MOCART 2.0 knee score ranging from 0 to 100 points may be reached. Four independent readers (two expert readers and two radiology residents with limited experience) assessed the 3 T MRI examinations of 24 patients, who had undergone cartilage repair of a femoral cartilage defect using the new MOCART 2.0 knee score. One of the expert readers and both inexperienced readers performed two readings, separated by a four-week interval. For the inexperienced readers, the first reading was based on the evaluation sheet only. For the second reading, a newly introduced atlas was used as an additional reference. Intrarater and interrater reliability was assessed using intraclass correlation coefficients (ICCs) and weighted kappa statistics. ICCs were interpreted according to Koo and Li; weighted kappa statistics were interpreted according to the criteria of Landis and Koch. The overall intrarater (ICC = 0.88, P < 0.001) as well as the interrater (ICC = 0.84, P < 0.001) reliability of the expert readers was almost perfect. Based on the evaluation sheet of the MOCART 2.0 knee score, the overall interrater reliability of the inexperienced readers was poor (ICC = 0.34, P < 0.019) and improved to moderate (ICC = 0.59, P = 0.001) with the use of the atlas. The MOCART 2.0 knee score was updated to account for changes in the past decade and demonstrates almost perfect interrater and intrarater reliability in expert readers. In inexperienced readers, use of the atlas may improve interrater reliability and, thus, increase the comparability of results across studies.

25 September 2015 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
RWReinhard Windhager
Reinhard Windhager
MSMarkus Schreiner
Markus Schreiner
KSKevin Staats
Kevin Staats
SASebastian Apprich
Sebastian Apprich

23 January 2016 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
MBMartin Brix
Martin Brix
MKMartin Kaipel
Martin Kaipel
RKRichard Kellner
Richard Kellner
MSMarkus Schreiner
Markus Schreiner
SASebastian Apprich
Sebastian Apprich
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig

31 January 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
KVKlemens Vertesich
Klemens Vertesich
SPStephan E. Puchner
Stephan E. Puchner
KSKevin Staats
Kevin Staats
MSMarkus Schreiner
Markus Schreiner
CHChristian Hipfl
Christian Hipfl
RWReinhard Windhager
Reinhard Windhager
Substantial bone loss following failed total knee arthroplasty (TKA) represents a major challenge in revision arthroplasty, that can require distal femoral reconstruction (DFR). In this study, we aimed to assess the clinical outcome and the complication frequencies of individuals who underwent DFR with modular megaprostheses. Additionally, we aimed to compare functional outcome measures after DFR in these sophisticated cases to an age-matched control group of total knee prostheses to quantify the potential loss of function. A retrospective chart review of 30 consecutive patients after DFR from 1997 to 2017 with a mean age of 74.38 years (± 10.1) was performed. Complications were classified according to the Henderson classification. Knee Society Score (KSS) was calculated and range of motion (ROM) was assessed. Thirteen (43.3%) patients had at least one complication requiring revision surgery. Revision-free survival was 74.8% at one year, 62.5% at three and 40.9% at 10 years post-op. Soft-tissue failure complications were found in three (10.0%) patients, aseptic loosening in four (13.3%) patients, structural failure in one (3.3%) patient and infection in eight (26.6%) patients. Of those with infection, five (16.6%) experienced ongoing prosthetic joint infection and three (10.0%) developed new infection after distal femur reconstruction. Patients with DFR achieved 69.3% of KSS pain score, 23.1% KSS function score and 76.2% of ROM compared to patients with primary TKA. DFR after failed TKA represents a treatment procedure with high risk for complication in this particular group. Despite the prospect of rapid postoperative mobilization, reduced functionality, range of motion and mobilization have to be considered when choosing this treatment option.

1 January 2017 in Investigative Radiology
Verified
Journal Article
Closed access
ESElisabeth Springer
Elisabeth Springer
KBKlaus Bohndorf
Klaus Bohndorf
VJVladimir Juras
Vladimir Juras
PSPavol Szomolanyi
Pavol Szomolanyi
ŠZŠtefan Zbýň
Štefan Zbýň
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
Objective: The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR] and diagnostic confidence) from a standard knee magnetic resonance imaging (MRI) examination with comparable sequence protocols and acquisition times at 3 T and at 7 T. Materials and Methods: Forty patients experiencing knee pain of unknown etiology underwent comparable MR protocols with standard turbo-spin echo and short tau inversion recovery sequences of the knee joint (5 sequences) at 3 T and 7 T. For quantitative analysis, SNR was determined using these 5 sequences and 3 additional morphological sequences. For a semiquantitative assessment of diagnostic confidence, a diagnostic confidence score (DCS) was assigned, using a 10-point scale. Two experienced radiologists who specialized in musculoskeletal imaging and who were blinded to the field-strength independently assessed 22 potential pathological findings, in total, in 4 anatomically defined areas in the knee joint and rated their diagnostic confidence. Results: In quantitative analysis, all sequences provided higher voxel-volume-adjusted SNR values at 7 T compared with that at 3 T. In semiquantitative analysis, summed DCS values for potential pathological findings in each of the 4 anatomically defined areas were higher at 7 T compared with that at 3 T. There was a statistically significant improvement in the DCS for both readers at 7 T for the diagnosis and exclusion of focal or diffuse grade I or II cartilage defects in the patellar cartilage. For 8 potential pathological findings, a statistically significant difference between the 2 field-strengths could be observed for 1 reader only. For the residual 13 potential pathological findings, there was no statistically significant difference observed. The percentage of concordant ratings was 84.6% at 3 T and 85.4% at 7 T. Conclusions: Ultra-high-field MRI at 7 T improved the overall diagnostic confidence in routine MRI of the knee joint compared with that at 3 T. This is especially true for small joint structures and subtle lesions. Higher spatial resolution was identified as the main reason for this improvement.

22 June 2016 in CARTILAGE
Verified
Journal Article
Open access
MSMarkus Schreiner
Markus Schreiner
Vladimir MlynarikVladimir Mlynarik
Vladimir Mlynarik
ŠZŠtefan Zbýň
Štefan Zbýň
PSPavol Szomolanyi
Pavol Szomolanyi
SASebastian Apprich
Sebastian Apprich
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
The incidence of osteochondral lesions, as well as osteoarthritis of the ankle joint following osteochondritis dissecans and trauma, has been reappraised in recent years. Consequently, an increasing number of surgical interventions using different cartilage repair techniques is performed in the ankle joint, which has resulted in a growing demand for repetitive and objective assessment of cartilage tissue and its repair. While morphological imaging does enable monitoring of macroscopic changes with increasing precision, it fails to provide information about the ultrastructural composition of cartilage. The significance of molecular changes in cartilage matrix composition, however, is increasingly recognized, as it is assumed that macroscopic cartilage degeneration is preceded by a loss in glycosaminoglycans and a disorganization of the collagen network. Recent advances in biochemical magnetic resonance imaging (MRI) have yielded sequences sensitive to these changes, thus providing invaluable insight into both early cartilage degeneration and maturation of repair tissue, on a molecular level. The aim of this review was to provide a comprehensive overview of these techniques, including water and collagen-sensitive T2/T2* mapping, as well as glycosaminoglycan-sensitive sequences such as delayed gadolinium-enhanced MRI of cartilage dGEMRIC, and sodium imaging, and describe their applications for the ankle joint.