Anna Suvorova

Mrs. Anna Suvorova

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in Pediatric Hematology/Oncology and Immunopathology
Verified
Journal Article
Open access
PDF file
DPDmitry Prudinnik
Dmitry Prudinnik
LKLarisa Koleva
Larisa Koleva
EBElizaveta Bovt
Elizaveta Bovt
NKNikita Kushnir
Nikita Kushnir
ASAnna Suvorova
Anna Suvorova
NSNataliya Sergeevna Smetanina
Nataliya Sergeevna Smetanina
The differential diagnosis of hereditary spherocytosis is a great challenge because of the similar clinical and laboratory signs it shares with other hereditary hemolytic anemias as well as due to the limited availability of molecular genetic testing. The development of easy-to-perform laboratory tests for the differential diagnosis of hereditary hemolytic anemias remains as relevant as ever. Here, a method of measuring red blood cell filterability for the diagnosis of hereditary spherocytosis is proposed for the first time. The aim of our study was to compare red blood cell filterability measurement with other diagnostic tests for hereditary spherocytosis as well as to assess its specificity and sensitivity. We included 30 patients (18 girls and 12 boys, with the median age of 8.6 years) with hereditary spherocytosis and 15 patients (9 girls and 6 boys, with the median age of 10 years) with other hereditary hemolytic anemias (pyruvate kinase deficiency (n = 14) and stomatocytosis (n = 1)). The diagnostic work-up for hereditary hemolytic anemia included a complete blood count test using an automated hematology analyzer, an osmotic resistance analysis before and after 24 hours of incubation at 37°С, erythrocytometry with sphericity index calculation, EMA test (eosin-5-maleimide binding assay) and red blood cell filterability measurement using artificial filters with cylindrical pores 3-5 μm in diameter. The study was approved by the Independent Ethics Committee and the Scientific Council of the Dmitry Rogachev National Medical Research Center of Pediatric Hematology, Oncology and Immunology. The parents of all of the enrolled children signed a voluntary informed consent form for peripheral blood collection and diagnostic testing. In all the cases of hereditary spherocytosis diagnosed in accordance with the relevant clinical recommendations, red blood cell filterability was very low (0–0.31 units). It was higher only in 3 instances, reaching 0.47, 0.64 and 0.82 units, but in two of these cases there were no genetic data available, and the remaining patient was found to harbor the SPTA1 c.433999CT mutation which was characterized both as spherocytosis and elliptocytosis. Red blood cell filterability in the group of the patients with other hemolytic anemias equalled 0.55 to 0.86 units (with the median of 0.77 units). The sensitivity of the RBC filterability measurement method in diagnosing hereditary spherocytosis was 93% (with 100% specificity), while the EMA test had a sensitivity of 89% and specificity of 95%. Our comparative study showed that red blood cell filterability measurement and the EMA test have similar sensitivity and specificity in diagnosing hereditary spherocytosis but the former is much cheaper and easier to perform since it does not require expensive equipment and can be carried out at any laboratory.

30 June 2026 in Pediatric Hematology/Oncology and Immunopathology
Verified
Journal Article
Open access
PDF file
ASAnna Suvorova
Anna Suvorova
NKNikita Kushnir
Nikita Kushnir
DPDmitry Prudinnik
Dmitry Prudinnik
EBElizaveta Bovt
Elizaveta Bovt
Fazoil I. AtaullakhanovFazoil I. Ataullakhanov
Fazoil I. Ataullakhanov
ESElena Sinauridze
Elena Sinauridze
Introduction. A common cause of hereditary hemolytic anemia is mutations of erythrocyte membrane proteins, which lead to a reduced ability of red blood cells (RBCs) to deform and pass through narrow capillaries and interendothelial slits of the spleen. This shortens the lifespan of erythrocytes and may result in hemolytic anemia. Therefore, the ability of RBCs to pass through narrow capillaries may serve as a good prognostic marker of a shortened RBC lifespan due to premature RBC hemolysis. The measurement of RBC filterability through artificial filters with 3–5 μm pore size (which is slightly smaller than the diameter of RBCs) might be the most suitable diagnostic method. However, the use of this method is hampered by poor reproducibility of its previously described variants. A recently proposed modified method for measuring RBC filterability using the IDA-01 device has demonstrated good sensitivity and specificity in the diagnosis of hereditary spherocytosis. However, its analytical performance (accuracy and specificity) has not yet been studied. Aim: to evaluate the analytical performance of the erythrocyte filterability measuring method using the IDA-01 filtrometer. Materials and methods. In this study, we used RBCs from healthy donors isolated from venous blood and washed using a standard procedure. The following parameters were analyzed: repeatability of the results (mean relative error and coefficient of variation) when measuring buffer flow time through the same filter (n = 10); reproducibility of the donor erythrocyte filterability measurements in two independent series of experiments conducted at different sites on different days (n = 15 and n = 31); and the reference range for normal filterability. The biological sensitivity of the method was also measured using suspensions containing varying amounts of non-filterable cells (RBCs exposed to 0.08% glutaraldehyde). All statistical calculations were performed using OriginPro 8.1 (OriginLab Corp., USA). Results and discussion. The IDA-01 device demonstrated good repeatability of measurements (relative error 2.79%, coefficient of variation 3.5%); the detection limit was 0.2 s; the reproducibility of erythrocyte filterability measurements in the two experimental series did not differ significantly (Fisher's test); the mean filterability values in these series also did not differ significantly (modified Student's t-test). The method is not biased. The reference range of filterability for donors was 0.81–0.87 (mean ± 1 standard deviation). The detection limit for pathologically altered cells was 0.003%. The accuracy of the results depends only on correct sample preparation (the degree of leukocyte removal and a constant hematocrit level in erythrocyte suspension). When all necessary conditions are met, the device specificity approaches 100%. Conclusion. The erythrocyte filterability test performed using the IDA-01 device has high sensitivity and specificity. It is very simple, does not require expensive equipment, and can be easily performed in any laboratory, making it a promising method for the diagnosis of hereditary spherocytosis.

5 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ESElena Sinauridze
Elena Sinauridze
EBElizaveta A. Bovt
Elizaveta A. Bovt
DPDmitry Prudinnik
Dmitry Prudinnik
IDIvan A. Dolgikh
Ivan A. Dolgikh
LKLarisa Koleva
Larisa Koleva
Fazoil I. AtaullakhanovFazoil I. Ataullakhanov
Fazoil I. Ataullakhanov
Hereditary hemolytic anemias (HHAs) have quite similar clinical manifestations, complicating differential diagnosis and determining treatment, such as splenectomy. For the differential diagnosis of hereditary spherocytosis (HS), pyruvate kinase deficiency (PKD), and hereditary stomatocytosis (HSt), we proposed to measure erythrocyte filterability through membrane filters with a pore diameter of 3 or 3.5 μm. Our modified method provides improved reproducibility reducing the variation in results caused by differences in the filters used. The filterability of erythrocytes significantly differs in patients with HS, HSt and PKD (medians and 1.5 IQR were: 0.045 [0; 0.51] (n=88); 0.685 [0.46; 0.79] (n=12) and 0.75 [0.55; 0.86] (n=28) rel. un., respectively). The specificity of the filterability test for HS diagnosis was 100%, comparable to the best available tests, while its sensitivity (85.2%) was somewhat lower than that of some alternative methods. Only the filterability test could identify a second subgroup in HS patients (14.8%) with higher filterability (close to normal), but their HS diagnosis was confirmed by the decreased filterability by 3-µm pore filter. This subgroup requires further detailed study. The proposed filterability measurement method is promising for diagnosing HS. It has high sensitivity and specificity and can be performed quickly without expensive equipment.

Verified
Journal Article
Open access
PDF file
ESElena Sinauridze
Elena Sinauridze
EBElizaveta A. Bovt
Elizaveta A. Bovt
DPDmitry Prudinnik
Dmitry Prudinnik
IDIvan A. Dolgikh
Ivan A. Dolgikh
LKLarisa Koleva
Larisa Koleva
Fazoil I. AtaullakhanovFazoil I. Ataullakhanov
Fazoil I. Ataullakhanov
Hereditary hemolytic anemias (HHAs) have very similar clinical manifestations, complicating differential diagnosis and determining treatment strategies, such as splenectomy. To differentiate between hereditary spherocytosis (HS), pyruvate kinase deficiency (PKD), and hereditary stomatocytosis (HSt), we proposed measuring erythrocyte filterability using membrane filters with a pore diameter of 3 or 3.5 μm. Our modified method provides improved reproducibility, reducing the scattering in results caused by differences in the filters used. Erythrocytes’ filterability differs significantly between patients with HS, HSt, and PKD (medians and 95% confidence intervals were 0.025 [0.004; 0.100] (n = 86); 0.645 [0.520; 0.730] (n = 10), and 0.760 [0.700; 0.782] (n = 26), respectively). The specificity of the filterability test for the HS diagnosis was 99.1%, comparable with the best available tests, while its sensitivity (85.4%) was slightly lower than that of some alternative methods. Only the filterability test was able to identify a second subgroup of HS patients (14.0%) with higher filterability (close to normal), but the diagnosis of HS in these patients could be confirmed by reduced filterability on a 3-μm filter. This subgroup requires further detailed study. The proposed method for measuring filterability is promising for diagnosing HS. It has high sensitivity and specificity and can be performed quickly without expensive equipment.