Shelley Keating

Dr. Shelley Keating

School of Human Movement and Nutrition Sciences, The University of Queensland, Australia.
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Journal of Hepatology
Verified
Journal Article
Closed access
SKShelley Keating
Shelley Keating
DHDaniel Hackett
Daniel Hackett
JGJacob George
Jacob George
NJNathan A. Johnson
Nathan A. Johnson

27 May 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MWMatthew P Wallen
Matthew P Wallen
SGSjaan Gomersall
Sjaan Gomersall
SKShelley Keating
Shelley Keating
UWUlrik Wisløff
Ulrik Wisløff
JCJeff S Coombes
Jeff S Coombes
Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67–0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16–0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1–9%) but greater for energy expenditure (9–43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.


26 September 2011 in Obesity Reviews
Verified
Journal Article
Closed access
PDF file
III. Ismail
I. Ismail
SKShelley Keating
Shelley Keating
MBM. K. Baker
M. K. Baker
NJN. A. Johnson
N. A. Johnson

1 July 2015 in Journal of Hepatology
Verified
Journal Article
Closed access
SKShelley Keating
Shelley Keating
DHDaniel Hackett
Daniel Hackett
HPHelen Parker
Helen Parker
HOHelen T. O’cOnnor
Helen T. O’cOnnor
JGJames A. Gerofi
James A. Gerofi
NJNathan A. Johnson
Nathan A. Johnson