Industrial CT is useful for defect detection, dimensional inspection and geometric analysis, while it does not meet the needs of industrial mass production because of its time-consuming imaging procedure. This article proposes a novel stationary real-time CT system, which is able to refresh the CT-reconstructed slices to the detector frame frequency. This structure avoids the movement of the X-ray sources and detectors. Projections from different angles can be acquired with the objects’ translation, making it easier to be integrated into production line. All the detectors are arranged along the conveyor and observe the objects in different angles of view. With the translation of objects, their X-ray projections are obtained for CT reconstruction. To decrease the mechanical size and reduce the number of X-ray sources and detectors, the FBP reconstruction algorithm was combined with deep-learning image enhancement. Medical CT images were applied to train the deep-learning network for its quantity advantage in comparison with industrial ones. It is the first time this source-detector layout strategy has been adopted. Data augmentation and regularization were used to elevate the generalization of the network. Time consumption of the CT imaging process was also calculated to prove its high efficiency. Our experiment shows that the reconstruction resulting in undersampled projections is highly enhanced using a deep-learning neural network which meets the demand of non-destructive testing. Meanwhile, our proposed system structure can perform quick scans and reconstructions on larger objects. It solves the pain points of limited scan size and slow scanning speed of existing industrial CT scans.
Industrial CT is useful for defect detection, dimensional inspection and geometric analysis. While it does not meet the needs of industrial mass production, because of its time-consuming imaging procedure. This article proposes a novel stationary real-time CT system, which is able to refresh the CT reconstructed slices to the detector frame frequency. This structure avoids the movement of the X-ray sources and detectors. Projections from different angles can be acquired with the objects’ translation, making it easier to be integrated into production line. All the detectors are arranged along the conveyor, and observe the objects in different angle of view. With the translation of objects, their X-ray projections are obtained for CT reconstruction. To decrease the mechanical size and reduce the number of X-ray sources and detectors, the FBP reconstruction algorithm was combined with deep-learning image enhancement. Medical CT images were applied to train the deep-learning network for its quantity advantage in comparison with industrial ones. It is the first time to adopt this source-detector layout strategy. Data augmentation and regularization were used to elevate the generalization of the network. Time consumption of the CT imaging process was also calculated to prove its high efficiency.
The noise of the inertial measurement units(IMU) is the important factor to degrade the precision of the inertial navigation system(INS). In order to improve the precision of the INS, it is necessary to de-noise the signal of the IMU correctly and precisely. A de-noising method for signal of quartz flexible accelerometer based on variational mode decomposition (VMD) algorithm is proposed in this paper. The signal of the quartz flexible accelerometer is decomposed into several modes, and every mode is processed through Consecutive Mean Square Error(CMSE). Experiment result indicate that the VMD filter can de-noise the signal of the quartz flexible accelerometer effectively. The static tests show that the de-noising method can increases the signal-to-noise ratio of the signal of the quartz flexible accelerometer and improve the precision of INS.
Energy spectrum CT can provide higher CT imaging resolution and thus play an important role in clinical diagnosis. X-ray Absorption Spectrum (XAS) instrument based on photon counting detector has great potentials in energy spectrum CT. The main problems of PCDs are “Stacking effect” and “charge sharing”, which can cause spectrum distortion and therefore depress imaging quality. It is quite complicated to correct spectral distortion through hardware improvements and physical simulation. Hence, we proposed a method for x-ray absorption spectrum data correction based on adversarial neural networks. The generator of our proposed can generate corrected spectrum after training. Spectrum data for correction in our experiments was collected by laboratory equipment and the ground-truth was obtained by simulation software. Real data and simulated data were feed to the network to train the generator and discriminator simultaneously. Results of our experiment illustrated that the well-trained network can effectively recover the spectrum from the distorted spectrum data. We also evaluate the imaging quality with the corrected spectrum data. It can be seen that the quality of CT reconstruction image can be significantly enhanced through corrected spectrum data. Our method of using adversarial neural networks to generate noise-free x-ray spectrum provides new ideas for the clinical application of energy spectrum CT.
21 February 2018 in DEStech Transactions on Computer Science and Engineering