Kim Greenwood

Mr. Kim Greenwood

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2022 in IEEE Access
Verified
Journal Article
Open access
YDYasmina Souley Dosso
Yasmina Souley Dosso
DKDaniel Kyrollos
Daniel Kyrollos
KGKim Greenwood
Kim Greenwood
JHJoann Harrold
Joann Harrold
JGJames Robert Green
James Robert Green
The development of non-contact patient monitoring applications for the neonatal intensive care unit (NICU) is an active research area, particularly in facial video analysis. Recent studies have used facial video data to estimate vital signs, assess pain from facial expression, differentiate sleep-wake status, detect jaundice, and in face recognition. These applications depend on an accurate definition of the patient’s face as a region of interest (ROI). Most studies have required manual ROI definition, while others have leveraged automated face detectors developed for adult patients, without systematic validation for the neonatal population. To overcome these issues, this paper first evaluates the state-of-the-art in face detection in the NICU setting. Finding that such methods often fail in complex NICU environments, we demonstrate how fine-tuning can increase neonatal face detector robustness, resulting in our NICUface models. A large and diverse neonatal dataset was gathered from actual patients admitted to the NICU across three studies and gold standard face annotations were completed. In comparison to state-of-the-art face detectors, our NICUface models address NICU-specific challenges such as ongoing clinical intervention, phototherapy lighting, occlusions from hospital equipment, etc. These analyses culminate in the creation of robust NICUface detectors with improvements on our most challenging neonatal dataset of +36.14, +35.86, and +32.19 in AP30, AP50, and mAP respectively, relative to state-of-the-art CE-CLM, MTCNN, img2pose, RetinaFace, and YOLO5Face models. Face orientation estimation is also addressed, leading to an accuracy of 99.45%. Fine-tuned NICUface models, gold-standard face annotation data, and the face orientation estimation method are also released here.

13 February 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DKDaniel G. Kyrollos
Daniel G. Kyrollos
AFAnthony Fuller
Anthony Fuller
KGKim Greenwood
Kim Greenwood
JHJoAnn Harrold
JoAnn Harrold
JGJames Robert Green
James Robert Green
Infant pose monitoring during sleep has multiple applications in both healthcare and home settings. In a healthcare setting, pose detection can be used for region of interest detection and movement detection for noncontact-based monitoring systems. In a home setting, pose detection can be used to detect sleep positions which has shown to have a strong influence on multiple health factors. However, pose monitoring during sleep is challenging due to heavy occlusions from blanket coverings and low lighting. To address this, we present a novel dataset, Simultaneously-collected multimodal Mannequin Lying pose (SMaL) dataset, for under the cover infant pose estimation. We collect depth and pressure imagery of an infant mannequin in different poses under various cover conditions. We successfully infer full body pose under the cover by training state-of-art pose estimation methods and leveraging existing multimodal adult pose datasets for transfer learning. We demonstrate a hierarchical pretraining strategy for transformer-based models to significantly improve performance on our dataset. Our best performing model was able to detect joints under the cover within 25mm 86% of the time with an overall mean error of 16.9mm. Data, code and models publicly available at https://github.com/DanielKyr/SMaL.

1 June 2018
Verified
Conference Paper
Closed access
ABAmente Bekele
Amente Bekele
SNShermeen Nizami
Shermeen Nizami
YDYasmina Souley Dosso
Yasmina Souley Dosso
CACheryl Aubertin
Cheryl Aubertin
KGKim Greenwood
Kim Greenwood
JGJames Robert Green
James Robert Green
We present an approach for real-time respiratory rate (RR) estimation in a neonatal intensive care unit (NICU) using a pressure-sensitive mat (PSM). Real patient data were collected in an NICU from four sources simultaneously: a PSM placed under the patient, a Draeger patient monitor, a video camera placed directly above the patient, and a custom bedside event annotation application running on a tablet. The PSM data were used to develop an algorithm for estimating the patient's RR. The results were evaluated against impedance pneumography (IP) based RR measurements from the patient monitor. In comparison to the IP estimates, we achieved a mean absolute error of 4.51 breaths per minute (bpm) for 3 hours of data collected from a single patient. Moreover, we show that our newer approach performs better than the previous frequency-based approach that was developed based on patient simulator data. The estimation accuracy achieved by the new algorithm meets clinical requirements for the determination of RR.

1 November 2021 in Computers in Biology and Medicine
Verified
Journal Article
Open access
YDYasmina Souley Dosso
Yasmina Souley Dosso
KGKim Greenwood
Kim Greenwood
JHJoAnn Harrold
JoAnn Harrold
JGJames Robert Green
James Robert Green
Continuity of care is achieved in the neonatal intensive care unit (NICU) through careful documentation of all events of clinical significance, including clinical interventions and routine care events (e.g., feeding, diaper change, weighing, etc.). As a step towards automating this documentation process, we propose a scene recognition algorithm that can automatically identify key features in a single image of the patient environment, paired with a rule-based sentence generator to caption the scene. Color and depth video were obtained from 29 newborn patients from the Children's Hospital of Eastern Ontario (CHEO) using an Intel RealSense SR300 RGB-D camera and manual bedside event annotation. Image processing techniques are implemented to classify two lighting conditions: brightness level and phototherapy. A deep neural network is developed for three image classification tasks: on-going intervention, bed occupancy, and patient coverage. Transfer learning is leveraged in the feature extraction layers, such that weights learned from a generic data-rich task are applied to the clinical domain where data collection is complex and costly. Different depth fusion techniques are implemented and compared among classification tasks, where the depth and color data are fused as an RGB-D image (image fusion) or separately at various layers in the network (network fusion). Promising results were obtained with >84% sensitivity and >73% F1 measure across all context variables despite the large class imbalance. RGBD-based models are shown to outperform RGB models on most tasks. In general, a 4-channel image fusion and network fusion at the 11th layer of the VGG-16 architecture were preferred. Ultimately, achieving complete scene understanding through multimodal computer vision could form the basis for a semi-automated charting system to assist clinical staff.

4 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ZHZein Hajj-Ali
Zein Hajj-Ali
YDYasmina Souley Dosso
Yasmina Souley Dosso
KGKim Greenwood
Kim Greenwood
JHJoAnn Harrold
JoAnn Harrold
JGJames Robert Green
James Robert Green
Depth cameras can provide an effective, noncontact, and privacy-preserving means to monitor patients in the Neonatal Intensive Care Unit (NICU). Clinical interventions and routine care events can disrupt video-based patient monitoring. Automatically detecting these periods can decrease the time required for hand-annotating recordings, which is needed for system development. Moreover, the automatic detection can be used in the future for real-time or retrospective intervention event classification. An intervention detection method based solely on depth data was developed using a vision transformer (ViT) model utilizing real-world data from patients in the NICU. Multiple design parameters were investigated, including encoding of depth data and perspective transform to account for nonoptimal camera placement. The best-performing model utilized ∼85 M trainable parameters, leveraged both perspective transform and HHA (Horizontal disparity, Height above ground, and Angle with gravity) encoding, and achieved a sensitivity of 85.6%, a precision of 89.8%, and an F1-Score of 87.6%.

1 January 2014 in Journal of Clinical Engineering
Verified
Journal Article
Closed access
KGKim Greenwood
Kim Greenwood
MJMarie-Ange Janvier
Marie-Ange Janvier
YZY. Rachel Basc Zhang
Y. Rachel Basc Zhang
GHGaëtanne Masc Heggie
Gaëtanne Masc Heggie
MYMarjan Masc Yazdanpanah
Marjan Masc Yazdanpanah
The growth of clinical engineering (CE) departments in the last 20 years has stalled within healthcare facilities despite the fact that the inventory of medical devices within all facilities has grown substantially during this interval. In many organizations, CE’s role is only to maintain the organization’s clinical equipment. The developmental strategy used by CE at the Children’s Hospital of Eastern Ontario has reversed this trend at this facility. This was accomplished by taking on the role of the health technology manager for the institution. Clinical engineering has, since 2001, coordinated the long-range planning function for capital equipment at Children’s Hospital of Eastern Ontario. Since taking on this role, CE has also been assigned the management of annual corporate capital equipment procurement process and coordination of the ongoing implementation of new clinical equipment.