Shermeen Nizami

Shermeen Nizami

Auto-generated profile, based on publicly available information

Shermeen Nizami

Systems and Computer Engineering, Carleton University, Ottawa, Canada

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2013 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
SNShermeen Nizami
Shermeen Nizami
JGJames Robert Green
James Robert Green
CMCarolyn McGregor
Carolyn McGregor
Artifact detection (AD) techniques minimize the impact of artifacts on physiologic data acquired in critical care units (CCU) by assessing quality of data prior to clinical event detection (CED) and parameter derivation (PD). This methodological review introduces unique taxonomies to synthesize over 80 AD algorithms based on these six themes: 1) CCU; 2) physiologic data source; 3) harvested data; 4) data analysis; 5) clinical evaluation; and 6) clinical implementation. Review results show that most published algorithms: a) are designed for one specific type of CCU; b) are validated on data harvested only from one OEM monitor; c) generate signal quality indicators (SQI) that are not yet formalized for useful integration in clinical workflows; d) operate either in standalone mode or coupled with CED or PD applications; e) are rarely evaluated in real-time; and f) are not implemented in clinical practice. In conclusion, it is recommended that AD algorithms conform to generic input and output interfaces with commonly defined data: 1) type; 2) frequency; 3) length; and 4) SQIs. This shall promote: a) reusability of algorithms across different CCU domains; b) evaluation on different OEM monitor data; c) fair comparison through formalized SQIs; d) meaningful integration with other AD, CED and PD algorithms; and e) real-time implementation in clinical workflows.

2 March 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SNShermeen Nizami
Shermeen Nizami
ABAmente Bekele
Amente Bekele
MHMohamed Hozayen
Mohamed Hozayen
KGKimberley J. Greenwood
Kimberley J. Greenwood
JHJoAnn Harrold
JoAnn Harrold
JGJames Robert Green
James Robert Green
We develop and evaluate a respiratory rate (RR) estimation algorithm that utilizes data from the pressure-sensitive mat (PSM) technology for continuous patient monitoring in neonatal intensive care units. An analysis of the random effect of drift and systematic effect of creep in the PSM data is presented, showing that these are essentially dependent on the applied load and contact surface. Uncertainty measurements are pivotal when estimating physiologic parameters. The standard uncertainty in the PSM data is here represented by the percent drift. Next, we evaluate the applicability of the PSM technology to estimate RR in neonatal patient simulator trials under five mixed effects including internally and externally induced motion, mattress type, grunting, laying position, and different breathing rates. We analyze the limits of agreement on the mixed effects model to derive the uncertainty in the estimated RR obtained through two estimation techniques. In comparison with the gold standard RR values, we achieved a mean bias of 0.56 breaths per minute (bpm) with an error bounded by a 95% confidence interval of [-2.26, 3.37] bpm. These results meet the clinical accuracy requirements of RR within ± 5 bpm.

1 June 2018
Verified
Conference Paper
Closed access
ABAmente Bekele
Amente Bekele
SNShermeen Nizami
Shermeen Nizami
YDYasmina Souley Dosso
Yasmina Souley Dosso
CACheryl Aubertin
Cheryl Aubertin
KGKim Greenwood
Kim Greenwood
JGJames Robert Green
James Robert Green
We present an approach for real-time respiratory rate (RR) estimation in a neonatal intensive care unit (NICU) using a pressure-sensitive mat (PSM). Real patient data were collected in an NICU from four sources simultaneously: a PSM placed under the patient, a Draeger patient monitor, a video camera placed directly above the patient, and a custom bedside event annotation application running on a tablet. The PSM data were used to develop an algorithm for estimating the patient's RR. The results were evaluated against impedance pneumography (IP) based RR measurements from the patient monitor. In comparison to the IP estimates, we achieved a mean absolute error of 4.51 breaths per minute (bpm) for 3 hours of data collected from a single patient. Moreover, we show that our newer approach performs better than the previous frequency-based approach that was developed based on patient simulator data. The estimation accuracy achieved by the new algorithm meets clinical requirements for the determination of RR.

1 January 2017
Verified
Conference Paper
Closed access
SNShermeen Nizami
Shermeen Nizami
MCMadison Cohen-McFarlane
Madison Cohen-McFarlane
JGJames Robert Green
James Robert Green
RGRafik Goubran
Rafik Goubran
Pressure-sensitive mat (PSM) technology offers several advantages as a sensor modality for patient monitoring since it is non-contact and unobtrusive. However, as we move to deploy PSM for long-term continuous patient monitoring, we must consider and characterize their metrological properties that arise due to their electrical, mechanical or optical construction. We evaluate the dynamic metrological properties of rise time, creep, percent change in creep, drift, and repeatability for three different PSM technologies from three vendors, namely, S4 (Kinotex fiber-optics), Tekscan (resistive ink), and XSensor (capacitive). Both long-term (14.5 hrs) and repeated short-term experiments (1 min) were conducted using two anthropometric models exhibiting contact pressures representative of adult and neonatal patients. Long-term experiments were conducted to characterize rise time, creep, percent change in creep, and drift for each sensor. With both pressure models, the XSensor exhibited the fastest dynamic response in terms of rise and recovery times, while Tekscan exhibited the slowest responses. S4 and Tekscan present with an expected decrease in drift with application of the adult model, but XSensor shows the opposite trend. Short-term experiments were conducted to measure repeatability with four application-removal repetitions for 1 min each. The coefficient of variation (CoV) was computed for each sensor as a measure of repeatability. For both pressure models, the smaller CoV of XSensor implies greater repeatability and hence, greater reliability.

1 April 2010
Verified
Conference Paper
Closed access
SNShermeen Nizami
Shermeen Nizami
JGJames Robert Green
James Robert Green
JEJ. Mikael Eklund
J. Mikael Eklund
CMCarolyn McGregor
Carolyn McGregor
Heart rate variability (HRV) is an established indicator of cardiac health. Recent developments have shown the potential of nonlinear metrics for pattern classification of various heart conditions. Evidence indicates that the combination of multiple linear and nonlinear features leads to increased classification accuracy. In our paper, we demonstrate HRV classification using two dynamic nonlinear techniques called Parallel Cascade Identification (PCI) and Fast Orthogonal Search (FOS). We investigate the use of these two techniques for feature extraction from publicly available Physionet electrocardiogram (ECG) data to differentiate between normal sinus rhythm of the heart and 3 undesired conditions: arrhythmia, supraventricular arrhythmia, and congestive heart failure. Results compare well with previous studies which have used more features over the same dataset. We hypothesize that combining PCI and FOS features with traditional HRV features will show further improvement in classification accuracy and so can assist in real-time patient monitoring.

1 May 2017
Verified
Conference Paper
Closed access
SNShermeen Nizami
Shermeen Nizami
ABAmente Bekele
Amente Bekele
MHMohamed Hozayen
Mohamed Hozayen
KGKim Greenwood
Kim Greenwood
JHJoAnn Harrold
JoAnn Harrold
JGJames Robert Green
James Robert Green
Pressure-sensitive mats (PSM) have proved to be useful in the estimation of respiratory rates (RR) in adult patients. However, PSM technology has not been extensively applied to derive physiologic parameters in infant and neonatal patients. This research evaluates the applicability of the capacitive XSensor PSM technology to estimate a range of RR in neonatal patient simulator trials conducted under several experimental conditions. PSM data are analyzed in both the time and frequency domain and comparative results are presented. For the frequency-domain approach, in addition to estimating RR, a measure of confidence is also derived from the relative height of peaks in the periodogram. The study demonstrates that frequency domain analysis of mean-shifted PSM data achieves the best possible RR estimation, with zero percent error, as compared to the lowest achievable RMS error of 1.57 percent in the time domain. The frequency domain approach outperforms the time domain analysis whether examining raw data or those preprocessed by normalizing, detrending and median filtering.