Pressure reducing valves (PRVs) are essentially used to reduce operational pressures in water distribution systems (WDSs) to minimize water leakage. However, water age in a WDS is an important variable describing the water quality and should be kept as low as possible. Therefore, the aim of this study is to investigate the possibility and potential of simultaneously minimizing both pressure and water age by using PRVs. To determine the optimal location and setting of PRVs, a mixed-integer nonlinear programming (MINLP) problem is formulated with minimization of the sum of the weighted total water age and pressure as the objective function, where the weighting factor can be defined by the user’s preference. The equality constraints consist of the hydraulic equations and water age functions to describe pressure and water age in the distribution network, while the inequality constraints ensure them in the defined operating ranges, respectively. Applying the proposed approach to two case studies, the results show that both water age and pressure can indeed be significantly reduced by the optimized position and setting of the PRVs.
The inherent uncertainty in water demand poses significant challenges to water distribution systems' (WDSs) efficiency and quality. This study introduces a model predictive control framework tailored for real‐time optimal operation of WDSs under uncertain demand and maximum water age constraints to ensure water quality requirements. The methodology presented utilizes a scenario‐based energy‐cost optimization approach to account for demand uncertainties. As water age is unmeasurable, a model linearly related to some measured/observed network variables (e.g., flows, water levels, etc.) is proposed to infer water age values. Then, a scenario‐based mixed‐integer linear programming problem is formulated and solved repeatedly online to adjust operational strategies for minimizing energy operation costs while satisfying water age constraints. The outcome of this model is a feasible operation scheme for all demand scenarios, providing a cost‐effective decision that meets water age limits. The proposed model is tested on a real‐world‐based test case and validated through a series of sensitivity analyses.
Most existing approaches to ensuring water quality in water distribution systems (WDSs) are deterministic, i.e., they do not consider uncertainties, although they may have significant impacts on the water quality. It is well recognized that water demand represents a predominant uncertainty in a WDS. In addition, water age is often used as an important parameter to describe the water quality in a WDS and can be influenced by water demand and control elements such as pressure-reducing valves (PRVs). Therefore, the aim of this study is to carry out a probabilistic analysis of the impact of demand uncertainty on the water age in the distribution network. Based on the solution of deterministic optimization to minimize the water age, Monte Carlo simulation will be carried out by sampling the uncertain demand to evaluate the stochastic distribution of water age, as well as other operating variables like pressure and flow. As a result, the probability of violating the constraints of such variables can be determined, with the reliability of the operating strategy (e.g., the settings of the PRVs) given by deterministic optimization provided. In cases of low reliability, it is necessary to modify the operating strategy in order to decrease the probability of constraint violation. For this purpose, a chance-constrained optimization problem is formulated, and its benefits for ensuring the user-defined reliability are studied. A benchmark network is used to verify the proposed approach.