Hao Cao

Mr. Hao Cao

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2019 in Water
Verified
Journal Article
Open access
PDF file
HCHao Cao
Hao Cao
SHSiegbert Hopfgarten
Siegbert Hopfgarten
Avi OstfeldAvi Ostfeld
Avi Ostfeld
Elad SalomonsElad Salomons
Elad Salomons
Pu LiPu Li
Pu Li
Many studies on pressure sensor (PS) placement and pressure reducing valve (PRV) localization in water distribution systems (WDSs) have been made with the objective of improving water leakage detection and pressure reduction, respectively. However, due to varying operation conditions, it is expected to realize pressure control using a number of PSs and PRVs to keep minimum operating pressure in real-time. This study aims to investigate the PS placement and PRV localization for the purpose of pressure control system design for WDSs. For such a control system, a PS should be positioned to represent the pressure patterns of a region of the WDS. Correspondingly, a PRV should be located to achieve a maximum pressure reduction between two neighboring regions. According to these considerations, an approach based on the k-means++ method for simultaneously determining the numbers and positions of both PSs and PRVs is proposed. Results from three case studies are presented to demonstrate the effectiveness of the suggested approach. It is shown that the sensors positioned have a high accuracy of pressure representation and the valves localized lead to a significant pressure reduction.

8 April 2024 in Water Resources Management
Verified
Journal Article
Open access
PDF file
KKKristina Korder
Kristina Korder
HCHao Cao
Hao Cao
Elad SalomonsElad Salomons
Elad Salomons
Avi OstfeldAvi Ostfeld
Avi Ostfeld
Pu LiPu Li
Pu Li
Pressure reducing valves (PRVs) are essentially used to reduce operational pressures in water distribution systems (WDSs) to minimize water leakage. However, water age in a WDS is an important variable describing the water quality and should be kept as low as possible. Therefore, the aim of this study is to investigate the possibility and potential of simultaneously minimizing both pressure and water age by using PRVs. To determine the optimal location and setting of PRVs, a mixed-integer nonlinear programming (MINLP) problem is formulated with minimization of the sum of the weighted total water age and pressure as the objective function, where the weighting factor can be defined by the user’s preference. The equality constraints consist of the hydraulic equations and water age functions to describe pressure and water age in the distribution network, while the inequality constraints ensure them in the defined operating ranges, respectively. Applying the proposed approach to two case studies, the results show that both water age and pressure can indeed be significantly reduced by the optimized position and setting of the PRVs.

13 September 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
HCHao Cao
Hao Cao
Pu LiPu Li
Pu Li
Contamination poses a significant risk to public health by degrading water quality in water distribution systems (WDSs). As one of the key tasks of a response strategy to contamination incidents in a WDS, pipe system flushing has been widely implemented in practice. However, due to the complexity of the network structure and chemical reaction within the pipe system, determining the flushing duration is still one of the significant challenges for a given network. To address this problem, a model for determining the flushing duration is developed. This model is based on calculating the traveling trajectory of the contaminant inside the network. This is carried out by discretizing the one-dimension advection equation and calculating the variation of the contaminant concentration from one segment to another over time. As a preliminary study, we focus on simplified scenarios where contaminants exhibit no chemical reaction within the WDS. The proposed model is applied and analyzed through a simulation study and a laboratory testbed. The results demonstrate the efficacy of the model for determining flushing duration, which can offer valuable insights for real-world applications and serve as a crucial reference for water utility companies.