Cheng YANG

Dr. Cheng YANG


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Chemical Engineering Journal
Verified
Journal Article
Closed access
CYCheng YANG
Cheng YANG
QFQiang Fu
Qiang Fu
XZXueping Zong
Xueping Zong
YDYixin Dong
Yixin Dong
WZWenhua Zhang
Wenhua Zhang
SXSong Xue
Song Xue

1 October 2010 in Materials Letters
Verified
Journal Article
Closed access
ZWZhiqi Wang
Zhiqi Wang
HWHongfen Wang
Hongfen Wang
CYCheng YANG
Cheng YANG
JWJinhu Wu
Jinhu Wu

25 June 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
YSYan Su
Yan Su
TLting liu
ting liu
CSCaiqiao Song
Caiqiao Song
AFAiqiao Fan
Aiqiao Fan
Nan ZhuNan Zhu
Nan Zhu
CYCheng YANG
Cheng YANG
As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability.

5 May 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
CYCheng YANG
Cheng YANG
FAFathimath Abbas
Fathimath Abbas
ARAmina Rhouati
Amina Rhouati
YSYingying Sun
Yingying Sun
XCXiaolin Chu
Xiaolin Chu
CXChangying Xue
Changying Xue
This study describes a quencher-free fluorescent aptasensor for ochratoxin A (OTA) detection using the specific quenching ability of guanine for fluorescein (FAM) molecules based on photo-induced electron transfer (PIET). In this strategy, OTA is detected by monitoring the fluorescence change induced by the conformational change of the aptamer after target binding. A new shorter OTA aptamer compromising three guanine bases at the 5′ end was used in this study. This new aptamer, named G3-OTAapt1-FAM (F1), was labeled with FAM on the 3′ end as a fluorophore. In order to increase the binding affinity of the aptamer and OTA, G3-OTAapt2-FAM (F2) was designed; this added a pair of complementary bases at the end compared with F1. To prevent the strong self-quenching of F2, a complementary chain, A13, was added. Although the F1 aptasensor was simpler to implement, the sensitivity of the F2 aptasensor with A13 was better than that of F1. The proposed F1 and F2 sensors can detect OTA with a concentration as low as 0.69 nmol/L and 0.36 nmol/L, respectively.

17 March 2024 in Talanta
Verified
Journal Article
Closed access
XLXiaobo Liu
Xiaobo Liu
BYBing Yin
Bing Yin
CYCheng YANG
Cheng YANG
SWShuo Wu
Shuo Wu

16 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
CYCheng YANG
Cheng YANG
XCXiaolin Chu
Xiaolin Chu
LZLi Zeng
Li Zeng
ARAmina Rhouati
Amina Rhouati
FAFathimath Abbas
Fathimath Abbas
DLDaiqin Lin
Daiqin Lin
G-quadruplexes have received significant attention in aptasensing due to their structural polymorphisms and unique binding properties. In this work, we exploited the fluorescence-quenching properties of G-quadruplex to develop a simple, fast, and sensitive platform for fluorescence detection of ochratoxin A (OTA) and potassium ions (K+) with a label-free fluorophore and quencher strategy. The quenching ability of G-quadruplex was confirmed during the recognition process after the formation of the G-quadruplex structure and the quenching of the labeled fluorescein fluorophore (FAM). The fluorescence-quenching mechanism was studied by introducing specific ligands of G-quadruplex to enhance the quenching effect, to show that this phenomenon is due to photo-induced electron transfer. The proposed fluorescence sensor based on G-quadruplex quenching showed excellent selectivity with a low detection limit of 0.19 nM and 0.24 µM for OTA and K+, respectively. Moreover, we demonstrated that our detection method enables accurate concentration determination of real samples with the prospect of practical application. Therefore, G-quadruplexes can be excellent candidates as quenchers, and the strategy implemented in the study can be extended to an aptasensor with G-quadruplex.