Luca Salhöfer

Dr. Luca Salhöfer

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2019 in Basic Research in Cardiology
Verified
Journal Article
Closed access
PDF file
TSTimm Schreiber
Timm Schreiber
LSLuca Salhöfer
Luca Salhöfer
TQTheresa Quinting
Theresa Quinting
JFJoachim Fandrey
Joachim Fandrey

11 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MHMathias Holtkamp
Mathias Holtkamp
LSLuca Salhöfer
Luca Salhöfer
NBNikolas Beck
Nikolas Beck
Lennard KrollLennard Kroll
Lennard Kroll
CZChristoph David Ziegenfuß
Christoph David Ziegenfuß
JHJohannes Haubold
Johannes Haubold
Background: This study aimed to evaluate the impact of an AI-assisted fracture detection program on radiology residents’ performance in pediatric and adult trauma patients and assess its implications for residency training. Methods: This study, conducted retrospectively, included 200 radiographs from participants aged 1 to 95 years (mean age: 40.7 ± 24.5 years), encompassing various body regions. Among these, 50% (100/200) displayed at least one fracture, totaling one hundred thirty-five fractures, assessed by four radiology residents with different experience levels. A machine learning algorithm was employed for fracture detection, and the ground truth was established by consensus among two experienced senior radiologists. Fracture detection accuracy, reporting time, and confidence were evaluated with and without AI support. Results: Radiology residents’ sensitivity for fracture detection improved significantly with AI support (58% without AI vs. 77% with AI, p < 0.001), while specificity showed minor improvements (77% without AI vs. 79% with AI, p = 0.0653). AI stand-alone performance achieved a sensitivity of 93% with a specificity of 77%. AI support for fracture detection significantly reduced interpretation time for radiology residents by an average of approximately 2.6 s (p = 0.0156) and increased resident confidence in the findings (p = 0.0013). Conclusion: AI support significantly enhanced fracture detection sensitivity among radiology residents, particularly benefiting less experienced radiologists. It does not compromise specificity and reduces interpretation time, contributing to improved efficiency. This study underscores AI’s potential in radiology, emphasizing its role in training and interpretation improvement.

16 September 2025 in Investigative Radiology
Verified
Journal Article
Closed access
AQAnton Sheahan Quinsten
Anton Sheahan Quinsten
CBChristian Bojahr
Christian Bojahr
KNKai Nassenstein
Kai Nassenstein
JSJannis Straus
Jannis Straus
MHMathias Holtkamp
Mathias Holtkamp
RHRené Hosch
René Hosch
Objectives: Manual field-of-view (FoV) prescription in whole-body magnetic resonance imaging (WB-MRI) is vital for ensuring comprehensive anatomic coverage and minimising artifacts, thereby enhancing image quality. However, this procedure is time-consuming, subject to operator variability, and adversely impacts both patient comfort and workflow efficiency. To overcome these limitations, an automated system was developed and evaluated that prescribes multiple consecutive FoV stations for WB-MRI using deep-learning (DL)-based three-dimensional anatomic segmentations. Materials and Methods: A total of 374 patients (mean age: 50.5 ± 18.2 y; 52% females) who underwent WB-MRI, including T2-weighted Half-Fourier acquisition single-shot turbo spin-echo (T2-HASTE) and fast whole-body localizer (FWBL) sequences acquired during continuous table movement on a 3T MRI system, were retrospectively collected between March 2012 and January 2025. An external cohort of 10 patients, acquired on two 1.5T scanners, was utilized for generalizability testing. Complementary nnUNet-v2 models were fine-tuned to segment tissue compartments, organs, and a whole-body (WB) outline on FWBL images. From these predicted segmentations, 5 consecutive FoVs (head/neck, thorax, liver, pelvis, and spine) were generated. Segmentation accuracy was quantified by Sørensen–Dice coefficients (DSC), Precision (P), Recall (R), and Specificity (S). Clinical utility was assessed on 30 test cases by 4 blinded experts using Likert scores and a 4-way ranking against 3 radiographer prescriptions. Interrater reliability and statistical comparisons were employed using the intraclass correlation coefficient (ICC), Kendall W, Friedman, and Wilcoxon signed-rank tests. Results: Mean DSCs were 0.98 for torso (P = 0.98, R = 0.98, S = 1.00), 0.96 for head/neck (P = 0.95, R = 0.96, S = 1.00), 0.94 for abdominal cavity (P = 0.95, R = 0.94, S = 1.00), 0.90 for thoracic cavity (P = 0.90, R = 0.91, S = 1.00), 0.86 for liver (P = 0.85, R = 0.87, S = 1.00), and 0.63 for spinal cord (P = 0.64, R = 0.63, S = 1.00). The clinical utility was evidenced by assessments from 2 expert radiologists and 2 radiographers, with 98.3% and 87.5% of cases rated as clinically acceptable in the internal test data set and the external test data set. Predicted FoVs received the highest ranking in 60% of cases. They placed within the top 2 in 85.8% of cases, outperforming radiographers with 9 and 13 years of experience (P < 0.001) and matching the performance of a radiographer with 20 years of experience. Conclusions: DL-based three-dimensional anatomic segmentations enable accurate and reliable multistation FoV prescription for WB-MRI, achieving expert-level performance while significantly reducing manual workload. Automated FoV planning has the potential to standardize WB-MRI acquisition, reduce interoperator variability, and enhance workflow efficiency, thereby facilitating broader clinical adoption.

7 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MWMatthias Welsner
Matthias Welsner
HNHenning Navel
Henning Navel
RHRene Hosch
Rene Hosch
PRPeter Rathsmann
Peter Rathsmann
FSFlorian Stehling
Florian Stehling
MOMarcel Opitz
Marcel Opitz
Background: Cystic fibrosis bone disease (CFBD) is a common comorbidity in adult people with cystic fibrosis (pwCF), resulting in an increased risk of bone fractures. This study evaluated the capacity of artificial intelligence (AI)-assisted low-dose chest CT (LDCT) opportunistic screening for detecting low bone mineral density (BMD) in adult pwCF. Methods: In this retrospective single-center study, 65 adult pwCF (mean age 30.1 ± 7.5 years) underwent dual-energy X-ray absorptiometry (DXA) of the lumbar vertebrae L1 to L4 to determine BMD and corresponding z-scores and completed LDCTs of the chest within three months as part of routine clinical care. A fully automated CT-based AI algorithm measured the attenuation values (Hounsfield units [HU]) of the thoracic vertebrae Th9–Th12 and first lumbar vertebra L1. The ability of the algorithm to diagnose CFBD was assessed using receiver operating characteristic (ROC) curves. Results: HU values of Th9 to L1 and DXA-derived BMD and the corresponding z-scores of L1 to L4 showed a strong correlation (all p < 0.05). The area under the curve (AUC) for diagnosing low BMD was highest for L1 (0.796; p = 0.001) and Th11 (0.835; p < 0.001), resulting in a specificity of 84.9% at a sensitivity level of 75%. The HU threshold values for distinguishing normal from low BMD were <197 (L1) and <212 (Th11), respectively. Conclusions: Routine LDCT of the chest with the fully automated AI-guided determination of thoracic and lumbar vertebral attenuation values is a valuable tool for predicting low BMD in adult pwCF, with the best results for Th11 and L1. However, further studies are required to define clear threshold values.

20 February 2025 in Journal of Cachexia, Sarcopenia and Muscle
Verified
Journal Article
Open access
LSLuca Salhöfer
Luca Salhöfer
GJGregor Jost
Gregor Jost
MMMathias Meetschen
Mathias Meetschen
DLDaniel van Landeghem
Daniel van Landeghem
MFMichael Forsting
Michael Forsting
JHJohannes Haubold
Johannes Haubold
Background: CT‐based body composition analysis (BCA) enables the extraction of biomarkers from routine CT data. The influence of body composition on the prognosis of different patient groups has been highlighted in recent years. Typically, the segmentation of muscle and fat compartments is performed with a thresholding‐based subsegmentation, which might be influenced by the image noise as a function of radiation dose. This study was performed to investigate the impact of the radiation dose on a fully automated, volumetric CT‐based BCA. Methods: In this animal study, 20 Göttingen minipigs were subjected to CT scans on six occasions under five different dose settings with gradations compared to the control given in % from volumetric CT dose index (CTDIvol) of the control (5%, 10%, 20%, 40%, control [10.01 mGy]). A database with full dose (FD) and quarter dose (QD) CT scans from The Cancer Imaging Archive served as a human validation cohort. A previously open‐source published and validated BCA network was applied to each scan. The following features were extracted as volumes (mL): bone, muscle, subcutaneous adipose tissue (SAT), intermuscular and intramuscular adipose tissue (IMAT), visceral adipose tissue (VAT) and total adipose tissue (TAT). Statistical significance was assessed by a one‐way ANOVA with Tukey's multiple comparisons or Kruskal–Wallis with Dunn's post‐hoc tests. The correlation between feature volumes in the dose gradations and the control group was analysed using the Spearman or Pearson method. Results: All BCA features remained consistent up to the 10% group and showed no significant differences compared with the control. In the lowest dose group (5%), there were significant differences concerning the muscle (5% = 1295 mL [211 mL], control = 1338 mL [248 mL]; p = 0.032) and VAT volumetry (5% = 353 mL [208 mL], control = 312 mL [204 mL]; p = 0.026) with median differences of −3.13% (muscle) and 12.3% (VAT), respectively. Significant and strong positive correlations were observed between all low‐dose groups and the control ( r > 0.977, p < 0.001). The human validation analysis yielded constant volumes for every BCA feature with a strong positive correlation ( r > 0.933, p < 0.001). Conclusions: Fully automated BCA maintains consistent results in various low‐dose settings. Significant deviations are only observed after more than 90% dose reduction in the lowest dose settings (5%), which are currently not used in the clinical routine. This large‐animal study demonstrates the consistency of fully automated BCA in different dose settings and may therefore facilitate its integration into the clinical routine.

19 January 2026 in Neuroradiology
Verified
Journal Article
Open access
PDF file
DRDaniel Rosok
Daniel Rosok
MOMarcel Opitz
Marcel Opitz
DBDenise Bos
Denise Bos
YTYannick Thal
Yannick Thal
MDMarcel Alexander Drews
Marcel Alexander Drews
SZSebastian Zensen
Sebastian Zensen
Purpose: In emergency diagnostics, head CT and CT angiography (CTA) of craniocervical vasculature are indispensable for children, despite their increased radiation sensitivity. This study assesses the radiation dose metrics of head CT and CTA in pediatric patients managed in the trauma resuscitation unit (TRU). Methods: All patients aged 0–<15 years who underwent head CT and CTA in the TRU between April 2020 and August 2023 were included. CT dose index volume (CTDIvol) and dose-length product (DLP) were extracted from the Radimetrics Enterprise Platform, which also provided organ doses estimated via Monte Carlo simulations and effective doses (ED) derived from these estimates. Dose metrics were compared with national diagnostic reference levels (DRLs), defined for three pediatric age groups: I (0–<5 years), II (5–<10 years), and III (10–<15 years). Results: Of 212 pediatric TRU patients, 62.7% (133/212) underwent CT and 72.2% (96/133) received combined CT and CTA. Median CTDIvol and DLP increased with age, whereas ED decreased. For head CT, CTDIvol ranged from 18.9 mGy to 29.4 mGy, DLP from 282 to 460 mGycm, and ED from 1.6 to 1.3 mSv. For CTA, CTDIvol ranged from 1.4 to 2.2 mGy, DLP from 40 to 83 mGycm, and ED from 1.0 to 0.8 mSv. All doses remained below national DRLs. Conclusion: Head CT and CTA in pediatric trauma can be performed with radiation doses well below national DRLs. Careful dose management is important to reduce potential long-term cancer risks and deterministic effects such as lens cataract formation.