Arne Nysveen

Prof. Dr. Arne Nysveen

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2018 in IEEE Industry Applications Magazine
Verified
Journal Article
Open access
MVMostafa Valavi
Mostafa Valavi
ANArne Nysveen
Arne Nysveen
In This article, the state of the art in the variable-speed operation of hydropower plants is reviewed, with a focus on pumped-storage hydropower. Relevant literature is reviewed to address the benefits of variable-speed operation for both power systems and hydropower facilities. Two main configurations to enable variable-speed operation-the doubly fed induction machine (DFIM) and the converter-fed synchronous machine (CFSM)-are discussed and compared. The article addresses the technology and energy policies of the past, present, and future and points out how the motivation, services, value, and technology of variable-speed hydropower plants have been subject to considerable change.

28 November 2013 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
MVMostafa Valavi
Mostafa Valavi
ANArne Nysveen
Arne Nysveen
RNRobert Nilssen
Robert Nilssen
RLRobert D. Lorenz
Robert D. Lorenz
TRTerje Rolvag
Terje Rolvag
In this paper, radial forces and torque ripple characteristics are investigated in permanent magnet (PM) machines having different pole and slot combinations. Using the PM machines with concentrated windings could be beneficial in direct-drive wind generators since it is possible to reduce the size and weight of the generator. The PM machines with concentrated windings having a large number of poles are compared to investigate the effect of pole and slot combinations on force and vibration characteristics in low-speed generators. Cogging torque waveforms and torque ripple are investigated using time-stepping finite-element analysis. Analysis of radial forces is presented, including investigation on radial force density distribution, total forces on teeth, and time-dependent force waveforms on a tooth. Structural analysis and experimental modal analysis are performed on the prototype generator. The main mode of vibration in the prototype machine is observed experimentally and the results are in good agreement with the simulations.

26 January 2021 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
HEHossein Ehya
Hossein Ehya
TSTarjei N. Skreien
Tarjei N. Skreien
ANArne Nysveen
Arne Nysveen
This article examines if machine learning (ML) and signal processing can be used for online condition monitoring to reveal interturn short circuit (ITSC) fault in the field winding of salient pole synchronous generators (SPSG). This was done by creating several ML classifiers to detect ITSC faults. A dataset for ML was built using power spectral density of the air-gap magnetic field extracted by fast Fourier transform, discrete wavelet transform energies, and Time Series FeatuRe Extraction based on Scalable Hypothesis tests (TSFRESH) to extract features from measurements of SPSG operated under several different severities of ITSC fault. Using this dataset, a wide range of classifiers were trained to detect the presence of ITSC faults. The classifiers evaluated were logistic regression, K -nearest neighbors, radial basis function support vector machine (SVM), linear SVM, XGBoost decision tree forest, multilayer perceptron, and a stacking ensemble classifier including all of the aforementioned. The classifiers were optimized using hyperparameter grid searches. In addition, some feature selection and reduction algorithms were assessed such as random forest feature selection, TSFRESH feature selection, and principal component analysis. This resulted in a classifier capable of detecting 84.5% of samples containing ITSC fault, with a 92.7% chance that fault detections are correct.

15 January 2010 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ACAnyuan Chen
Anyuan Chen
RNRobert Nilssen
Robert Nilssen
ANArne Nysveen
Arne Nysveen
The aim of this paper is to provide performance comparisons among conventional radial-flux, multistage axial-flux, and three-phase transverse-flux permanent-magnet machines for downhole applications where the outer diameters are limited by well sizes, but the axial lengths can be relatively long. The comparison procedure is based on a high ambient temperature of 150°C, a small outer diameter of 100 mm, a current density of 4 A/mm2 , an electrical loading of 20 kA/m, and a constant speed of 1000 r/min, with their output torques being from several newton meters to 105 N·m and power up to 18 kVA. Three machine prototypes are chosen and optimized individually in terms of maximum torque density on the basis of some common constraints. The comparisons are focused on the torque density, machine efficiency, and power factor with respect to different pole numbers and axial lengths. For a specific downhole application without an external cooling system, the obtained results provide an indication of machines best suited with respect to performance and size.

13 April 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HEHossein Ehya
Hossein Ehya
ANArne Nysveen
Arne Nysveen
This article provides a novel approach for discriminating the interturn short circuit (ITSC) fault in a salient pole synchronous generator (SPSG) based on the use of noninvasive sensors. A stray magnetic field is used as a signal that can provide valuable data regarding the health condition of the SPSG. Generally, the captured signal under an ITSC fault is examined using a classical signal processing tool based on fast Fourier transforms (FFTs). The amplitude of the side-bands to the frequency spectrum is increased by ITSC, eccentricity, and broken damper-bar faults. Therefore, determining the type of fault is not possible by analyzing the FFT side-bands. A unique feature is introduced using a short-time Fourier transform to identify the ITSC in its early stage. The proposed feature can locate and recognize the ITSC fault with high accuracy in either the no-load or the full-load operation of the SPSG. This novel methodology is verified by applying an ITSC fault to a 100 kVA custom-made SPSG.

4 March 2014 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MVMostafa Valavi
Mostafa Valavi
ANArne Nysveen
Arne Nysveen
RNRobert Nilssen
Robert Nilssen
TRTerje Rolvag
Terje Rolvag
In this paper, the influence of slot harmonics on magnetic forces and vibration is studied in a 120-slot/116-pole low-speed PM machine at no-load. It is shown how the lowest mode of vibration is produced at no-load due to slotting. Comparing the cases of open slots, semi-closed slots and magnetic wedges, the effect of slot closure on radial forces and torque production capability is discussed. Magnetic flux distribution in the airgap is computed using finite element analysis. Spatial harmonics due to slotting are investigated in different cases. Maxwell's stress tensor is employed to calculate radial and tangential components of the force density in the airgap. Spatial distribution of the total forces on the teeth and also time-dependent force waveform on one tooth are analyzed and discussed for different cases. It is shown how the magnitude of the lowest mode of vibration is reduced in the case of using semi-closed slots and magnetic wedges. Tangential force density distribution and torque production capability are also discussed. Structural analysis is presented to compute the maximum amplitude of the stator deformations due to the radial forces. Experimental results of the prototype generator are presented verifying the existence of the lowest mode of vibration at no-load because of the slot harmonics.