In This article, the state of the art in the variable-speed operation of hydropower plants is reviewed, with a focus on pumped-storage hydropower. Relevant literature is reviewed to address the benefits of variable-speed operation for both power systems and hydropower facilities. Two main configurations to enable variable-speed operation-the doubly fed induction machine (DFIM) and the converter-fed synchronous machine (CFSM)-are discussed and compared. The article addresses the technology and energy policies of the past, present, and future and points out how the motivation, services, value, and technology of variable-speed hydropower plants have been subject to considerable change.
In this paper, rotor inter-turn faults in salient-pole synchronous machines are investigated using finite-element analysis. The machine under study is a 22 MVA eight-pole hydropower generator with fractional-slot windings. Simulated faulty cases include 1, 2, 5, 10, and 20 short-circuited turns (out of 58 turns) in one rotor pole. In the electromagnetic analysis, the effect of faults on airgap flux density and radial forces is studied. Furthermore, this paper investigates online detection of inter-turn faults using spectral analysis of stator voltage or current is studied. The amplitude of fault-related harmonics is investigated at various fault severities, as well as at no-load and full-load operations. This paper also discusses the effects of damper bars, an influence of parallel circuits in the stator windings, and influence of the pole pair number. In addition, a comparison between fault-related harmonics in the case of dynamic eccentricity and rotor inter-turn faults is presented.
5 February 2018 in IEEE Transactions on Industry Applications
This paper investigates the effects of converter-fed operation on magnetic forces and vibration in a hydrogenerator. The variable-speed hydrogenerator (in a pumped-storage power plant) is a large synchronous machine with fractional-slot windings. In this study, the generator is connected to either resistive load or voltage source converter. Loading cases include two-level converter and three-level neutral-point-clamped converter and the carrier frequency is equal to 450 Hz and 1050 Hz. Using electromagnetic finite element (FE) analysis, airgap flux density harmonics are analyzed in different loading cases. In addition, electromagnetic torque and variations in the rotor field current are also studied. Using Maxwell stress tensor, radial force density distribution in the airgap is investigated and the effect of converter-fed operation on different radial force harmonics are studied. Moreover, structural analysis and electromagnetic vibration synthesis are presented to investigate the effect of converter harmonics on the stator vibration.
This paper investigates spatial and time harmonics of flux density and radial force distributions in the airgap of a hydrogenerator with fractional-slot windings. Hydrogenerator is connected to a neutral-point-clamped (NPC) converter, representing a converter-fed synchronous machine (CFSM) in pumped-storage hydropower plant. Magnetic field in the hydrogenerator is computed using time-stepping finite element (FE) analysis, coupled with an external circuit (where PWM converter is modelled). Radial forces are calculated analytically based on Maxwell stress tensor. Three loading conditions are studied (i.e. resistive loading and converter-fed operation with two different carrier frequencies). In the paper, it is investigated how converter-fed operation could change the characteristics of the radial magnetic forces. It is also discussed how vibration of the hydrogenerator is expected to be affected by additional harmonics generated by the PWM converter.
In this paper, the importance of maintenance of marine propulsion is discussed with specific focus on the use of condition monitoring to inform maintenance schedules. The design requirements of DNV GL for shafts expected to operate in ice infested waters is adapted and a method is proposed to calculate the short-term fatigue damage during ice impacts. This method uses the Palmgren-Miner rule to calculate fatigue damage based on a transient, lumped-mass model simulation of the shaft with ice loads calculated from shaft measurements using inverse methods. Relevant sources of uncertainty in this assessment method are identified and quantified in order to express the short-term fatigue damage in a stochastic form. Sources of uncertainty include uncertainty in the calculation of ice loads, uncertainty of the transient analysis and uncertainty regarding the actual failure of the shaft as predicted by the S-N material curve and the Palmgren-Miner method. Uncertainties that influence the stress history are found to be the greatest contributor to fatigue damage uncertainty. A method is discussed that calculates the remaining useful life of the shaft as a function of short-term fatigue damage and the identified sources of uncertainty. The S.A. Agulhas is used as a case study to quantify the fatigue damage.