Vincent Vaccher

Dr. Vincent Vaccher

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Environment International
Verified
Journal Article
Open access
VVVincent Vaccher
Vincent Vaccher
LILuc Ingenbleek
Luc Ingenbleek
Abimbola AdegboyeAbimbola Adegboye
Abimbola Adegboye
SHSétondji Epiphane Hossou
Sétondji Epiphane Hossou
AKAbdoulaye Zié Koné
Abdoulaye Zié Koné
BBBruno Le Bizec
Bruno Le Bizec
For the first time, a multi-centre Total Diet Study was carried out in Benin, Cameroon, Mali and Nigeria. We collected and prepared as consumed 528 typical fatty foods from those areas and pooled these subsamples into 44 composites samples. These core foods were tested for a wide spectrum of POPs, including polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), brominated flame-retardants (BFRs), organochlorine compounds (OCs), perfluoro alkyl substances (PFAS) and chlorinated flame retardants (CFRs). The POPs contamination levels were similar or lower than those reported in total diet studies previously conducted worldwide. In most cases, core foods belonging to fish food group presented higher POPs concentrations than the other food groups. Interestingly, we observed a difference in both contamination profile and concentration for smoked fish compared to non-smoked fish. Such finding suggests that the smoking process itself might account for a large proportion of the contamination. Further investigation would require the assessment of combustion materials used to smoke fish as a potential vehicle, which may contribute to the dietary exposure of the studied populations to POPs.

1 May 2021 in International Journal of Hygiene and Environmental Health
Verified
Journal Article
Open access
SNStefanie Nübler
Stefanie Nübler
MLMarta Esteban López
Marta Esteban López
ACArgelia Castaño
Argelia Castaño
HMHans Mol
Hans Mol
MSMoritz Schäfer
Moritz Schäfer
Thomas GöenThomas Göen
Thomas Göen
Human biomonitoring (HBM) of cadmium is essential to assess and prevent toxic exposure. Generally, low cadmium levels in urine and blood of the general population place particularly high demands on quality assurance and control measures (QA/QC) for cadmium determination. One of the aims of the HBM4EU project is to harmonize and advance HBM in Europe. Cadmium is one of the chemicals selected as a priority substance for HBM implementation in the 30 European countries under HBM4EU. For this purpose, analytical comparability and accuracy of the analytical laboratories of participating countries was investigated in a QA/QC programme comprising interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS). This paper presents the evaluation process and discusses the results of four ICI/EQUAS rounds for the determination of cadmium in urine and blood. The majority of the 43 participating laboratories achieved satisfactory results, although low limits of quantification were required to quantify Cd concentrations at general population exposure levels. The relative standard deviation of the participants' results obtained from all ICI and EQUAS runs ranged from 8 to 36% for cadmium in urine and 8-28% for cadmium in blood. Applying inductively-coupled plasma mass spectrometry (ICP-MS), using an internal standard, and eliminating molybdenum oxide interferences was favourable for the accurate determination of cadmium in urine and blood. Furthermore, the analysis of cadmium in urine was found to have a critical point at approximately 0.05 μg/l, below which variability increased and laboratory proficiency decreased. This QA/QC programme succeeded in establishing a network of laboratories with high analytical comparability and accuracy for the analysis of cadmium across 20 European countries.

17 February 2022 in Environmental Research
Verified
Journal Article
Open access
VVVincent Vaccher
Vincent Vaccher
Marta Esteban LópezMarta Esteban López
Marta Esteban López
ACArgelia Castaño
Argelia Castaño
HMHans Mol
Hans Mol
KHKarin Haji-Abbas-Zarrabi
Karin Haji-Abbas-Zarrabi
JAJean-Philippe Antignac
Jean-Philippe Antignac
The Human Biomonitoring for Europe initiative (HBM4EU) aims to study the exposure of citizens to chemicals and potentially associated health effects. One objective of this project has been to build a network of laboratories able to answer to the requirements of European human biomonitoring studies. Within the HBM4EU quality assurance and quality control scheme (QA/QC), a number of interlaboratory comparison investigations (ICIs) and external quality assurance schemes (EQUASs) were organized to ensure data consistency, comparability and reliability. Bisphenols are among the prioritized substance groups in HBM4EU, including bisphenol A (BPA), bisphenol S (BPS) and bisphenol F (BPF) in human urine. In four rounds of ICI/EQUAS, two target concentration levels were considered, related to around P25 and P95 of the typical exposure distribution observed in the European general population. Special attention was paid to the conjugated phase II metabolites known to be most dominant in samples of environmentally exposed individuals, through the analysis of both native samples and samples fortified with glucuronide forms. For the low level, the average percentage of satisfactory results across the four rounds was 83% for BPA, 71% for BPS and 62% for BPF. For the high level, the percentages of satisfactory results increased to 93% for BPA, 89% for BPS and 86% for BPF. 24 out of 32 participating laboratories (75%) were approved for the analyses of BPA in the HBM4EU project according to the defined criterion of Z-scores for both low and high concentration levels in at least two ICI/EQUAS rounds. For BPS and BPF, the number of qualified laboratories was 18 out of 27 (67%) and 13 out of 28 (46%), respectively. These results demonstrate a strong analytical capability for BPA and BPS in Europe, while improvements may be needed for BPF.

26 January 2022 in Toxics
Verified
Journal Article
Open access
PDF file
HMHans Mol
Hans Mol
IEIngrid Elbers
Ingrid Elbers
CPClaudia Pälmke
Claudia Pälmke
DBDaniel Bury
Daniel Bury
Thomas GöenThomas Göen
Thomas Göen
Holger KochHolger Koch
Holger Koch
A quality assurance/quality control program was implemented in the framework of the EU project HBM4EU to assess and improve the comparability of biomarker analysis and to build a network of competent laboratories. Four rounds of proficiency tests were organized for 15 phthalate and two DINCH urinary biomarkers (0.2–138 ng/mL) over a period of 18 months, with the involvement of 28 laboratories. A substantial improvement in performance was observed after the first round in particular, and by the end of the program, an average satisfactory performance rate of 90% was achieved. The interlaboratory reproducibility as derived from the participants’ results varied for the various biomarkers and rounds, with an average of 24% for the biomarkers of eight single-isomer phthalates (e.g., DnBP and DEHP) and 43% for the more challenging biomarkers of the mixed-isomer phthalates (DiNP, DiDP) and DINCH. When the reproducibility was based only on the laboratories that consistently achieved a satisfactory performance, this improved to 17% and 26%, respectively, clearly demonstrating the success of the QA/QC efforts. The program thus aided in building capacity and the establishment of a network of competent laboratories able to generate comparable and accurate HBM data for phthalate and DINCH biomarkers in 14 EU countries. In addition, global comparability was ensured by including external expert laboratories.

1 November 2021 in Environmental Research
Verified
Journal Article
Open access
DDDarina Dvořáková
Darina Dvořáková
JPJana Pulkrabova
Jana Pulkrabova
TGTomas Gramblicka
Tomas Gramblicka
APAndrea Polachova
Andrea Polachova
MBMartina Buresova
Martina Buresova
JHJana Hajslova
Jana Hajslova
The European Human Biomonitoring Initiative (HBM4EU) is coordinating and advancing human biomonitoring (HBM). For this purpose, a network of laboratories delivering reliable analytical data on human exposure is fundamental. The analytical comparability and accuracy of laboratories analysing flame retardants (FRs) in serum and urine were investigated by a quality assurance/quality control (QA/QC) scheme comprising interlaboratory comparison investigations (ICIs) and external quality assurance schemes (EQUASs). This paper presents the evaluation process and discusses the results of four ICI/EQUAS rounds performed from 2018 to 2020 for the determination of ten halogenated flame retardants (HFRs) represented by three congeners of polybrominated diphenyl ethers (BDE-47, BDE-153 and BDE-209), two isomers of hexabromocyclododecane (α-HBCD and γ-HBCD), two dechloranes (anti-DP and syn-DP), tetrabromobisphenol A (TBBPA), decabromodiphenylethane (DBDPE), and 2,4,6-tribromophenol (2,4,6-TBP) in serum, and four metabolites of organophosphorus flame retardants (OPFRs) in urine, at two concentration levels. The number of satisfactory results reported by laboratories increased during the four rounds. In the case of HFRs, the scope of the participating laboratories varied substantially (from two to ten) and in most cases did not cover the entire target spectrum of chemicals. The highest participation rate was reached for BDE-47 and BDE-153. The majority of participants achieved more than 70% satisfactory results for these two compounds over all rounds. For other HFRs, the percentage of successful laboratories varied from 44 to 100%. The evaluation of TBBPA, DBDPE, and 2,4,6-TBP was not possible because the number of participating laboratories was too small. Only seven laboratories participated in the ICI/EQUAS scheme for OPFR metabolites and five of them were successful for at least two biomarkers. Nevertheless, the evaluation of laboratory performance using Z-scores in the first three rounds required an alternative approach compared to HFRs because of the small number of participants and the high variability of experts' results. The obtained results within the ICI/EQUAS programme showed a significant core network of comparable European laboratories for HBM of BDE-47, BDE-153, BDE-209, α-HBCD, γ-HBCD, anti-DP, and syn-DP. On the other hand, the data revealed a critically low analytical capacity in Europe for HBM of TBBPA, DBDPE, and 2,4,6-TBP as well as for the OPFR biomarkers.

26 October 2022 in Environmental Research
Verified
Journal Article
Closed access
AMAourell Mauffret
Aourell Mauffret
TCTiphaine Chouvelon
Tiphaine Chouvelon
NWNathalie Wessel
Nathalie Wessel
PCPierre Cresson
Pierre Cresson
DBDaniela Bănaru
Daniela Bănaru
MHMireille Harmelin-Vivien
Mireille Harmelin-Vivien