Ke Zhang

Mr. Ke Zhang


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Therapeutics and Clinical Risk Management
Verified
Journal Article
Open access
PDF file
YWYu-Tuan Wu
Yu-Tuan Wu
ZXZhou Xu
Zhou Xu
KZKe Zhang
Ke Zhang
JWJiu-Song Wu
Jiu-Song Wu
XLXin Li
Xin Li
LKLingquan Kong
Lingquan Kong
The concurrent use of trastuzumab and anthracycline-based neoadjuvant chemotherapy (NAC) has been proposed to improve the pathologic complete response (pCR) rate, although there are conflicting views about its efficacy and safety. The purpose of this study was to evaluate the efficacy and cardiac safety of the concurrent use of trastuzumab and anthracycline-based NAC for human epidermal growth factor receptor 2 (HER2)-positive locally advanced breast cancer. We systematically searched PubMed, Embase, and Cochrane databases from inception until July 1, 2017, for relevant articles. A total of 13 studies were included in the meta-analysis. The results showed that the pCR rate was significantly higher in the concurrent use of trastuzumab and anthracycline group (45%) than that in the nonconcurrent use group (32%) (OR: 2.36, 95% CI: 1.69–3.30, P10% (OR: 1.26, 95% CI: 0.55–2.88, P=0.59), and in terms of cardiac failure (OR: 2.17, 95% CI: 0.24–19.84, P=0.49), when comparing the concurrent use of trastuzumab and anthracyclines with their nonconcurrent use. In conclusion, the concurrent use of trastuzumab and anthracycline-based NAC for certain HER2-positive locally advanced breast cancers significantly improves the pCR rates without obvious increases in the cardiotoxicity.

19 February 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
KZKe Zhang
Ke Zhang
STSimon M. F. Triphan
Simon M. F. Triphan
CZChristian H. Ziener
Christian H. Ziener
JJJohann M. E. Jende
Johann M. E. Jende
HKHans‐Ulrich Kauczor
Hans‐Ulrich Kauczor
FKFelix T. Kurz
Felix T. Kurz
PurposeTo apply a navigator-based slice-tracking method to prospectively compensate respiratory motion for kidney pseudo-continuous arterial spin labeling (pCASL), using spin-echo (SE) EPI acquisition. MethodsA single gradient-echo slice selection and projection readout at the location of the diaphragm along the inferior-superior direction was applied as a navigator. Navigator acquisition and fat suppression were inserted before each transverse imaging slice of the readouts of a 2D-SE-EPI-based pCASL sequence. Motion information was calculated after exclusion of the signal saturation in the navigator signal caused by EPI excitations. The motion information was then used to directly adjust the slice positioning in real time. ResultsThe respiratory motion from the navigator signal was calculated, and slice positioning was changed in real time based on the motion information. We could show that motion compensation reduces kidney movement, and that the coefficients of variation across renal perfusion values were significantly reduced when motion correction was applied. The average reduction of coefficients of variation was approximately 20%, resulting in a more accurate and detailed structure of the respective perfusion maps. ConclusionsThis study demonstrates the feasibility of a navigator-based slice-tracking technique in kidney imaging with a SE-EPI readout pCASL sequence to reduce kidney motion.

19 July 2004
Verified
Reference Entry
Closed access
PDF file
KZKe Zhang
Ke Zhang
QWQiang Wei
Qiang Wei

25 July 2024 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
AHAnja Hohmann
Anja Hohmann
KZKe Zhang
Ke Zhang
CMChristoph M. Mooshage
Christoph M. Mooshage
JJJohann M.E. Jende
Johann M.E. Jende
LRLukas T. Rotkopf
Lukas T. Rotkopf
FKFelix T. Kurz
Felix T. Kurz
BACKGROUND AND PURPOSE: The novel MR imaging technique of vascular architecture mapping allows in vivo characterization of local changes in cerebral microvasculature, but reference ranges for vascular architecture mapping parameters in healthy brain tissue are lacking, limiting its potential applicability as an MR imaging biomarker in clinical practice. We conducted whole-brain vascular architecture mapping in a large cohort to establish vascular architecture mapping parameter references ranges and identify region-specific cortical and subcortical microvascular profiles. MATERIALS AND METHODS: This was a single-center examination of adult patients with unifocal, stable low-grade gliomas with multiband spin- and gradient-echo EPI sequence at 3T using parallel imaging. Voxelwise plotting of resulting values for gradient-echo (R2*) versus spin-echo (R2) relaxation rates during contrast agent bolus administration generates vessel vortex curves that allow the extraction of vascular architecture mapping parameters representative of, eg, vessel type, vessel radius, or CBV in the underlying voxel. Averaged whole-brain parametric maps were calculated for 9 parameters, and VOI analysis was conducted on the basis of a standardized brain atlas and individual cortical GM and WM segmentation. RESULTS: Prevalence of vascular risk factors among subjects (n = 106; mean age, 39.2 [SD, 12.5] years; 56 women) was similar to those in the German population. Compared with WM, we found cortical GM to have larger mean vascular calibers (5.80 [SD, 0.59] versus 4.25 [SD, 0.62] P < .001), increased blood volume fraction (20.40 [SD, 4.49] s−1 versus 11.05 [SD, 2.44] s−1; P < .001), and a dominance of venous vessels. Distinct microvascular profiles emerged for cortical GM, where vascular architecture mapping vessel type indicator differed, eg, between the thalamus and cortical GM (mean, −2.47 [SD, 4.02] s−2 versus −5.41 [SD, 2.84] s−2; P < .001). Intraclass correlation coefficient values indicated overall high test-retest reliability for vascular architecture mapping parameter mean values when comparing multiple scans per subject. CONCLUSIONS: Whole-brain vascular architecture mapping in the adult brain reveals region-specific microvascular profiles. The obtained parameter reference ranges for distinct anatomic and functional brain areas may be used for future vascular architecture mapping studies on cerebrovascular pathologies and might facilitate early discovery of microvascular changes, in, eg, neurodegeneration and neuro-oncology.

20 August 2017 in The Journal of Clinical Hypertension
Verified
Journal Article
Open access
PDF file
WHWeizhong Han
Weizhong Han
NSNingling Sun
Ningling Sun
LCLianghua Chen
Lianghua Chen
SJShiliang Jiang
Shiliang Jiang
YCYunchao Chen
Yunchao Chen
XHXiao Han
Xiao Han
This study was conducted to explore whether the renin C‐5312T, angiotensin II type 1 receptor A1166C, and angiotensin‐converting enzyme I/D polymorphisms were associated with ambulatory blood pressure (BP) and central hemodynamics in an untreated hypertensive population. A total of 471 participants with no previous treatment for raised BP were eligible for the study. Ambulatory and central BP were measured. DD carriers had the highest daytime systolic/diastolic BP, nighttime systolic BP, 24‐hour systolic BP, and 24‐hour diastolic BP values, whereas carriers of DD had higher central systolic BP and augmentation index compared with those with the II genotype. Multivariate regression analysis demonstrated that DD genotype was independently associated with 24‐hour systolic BP, 24‐hour diastolic BP, central systolic BP, and central augmentation index. There was an independent association of the angiotensin‐converting enzyme polymorphism with central and ambulatory BP in Chinese patients with hypertension.

2 July 2024 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
KZKe Zhang
Ke Zhang
STSimon M.F. Triphan
Simon M.F. Triphan
MWMark O. Wielpuetz
Mark O. Wielpuetz
CZChristian Herbert Ziener
Christian Herbert Ziener
MLMark E. Ladd
Mark E. Ladd
FKFelix T. Kurz
Felix T. Kurz
To apply velocity selective arterial spin labeling (VSASL) combined with a navigator-based (NAV) prospective motion compensation method for a free-breathing liver perfusion measurement without contrast agent. Sinc-modulated Velocity Selective Inversion (sinc-VSI) pulses were applied as labeling and control pulses. In order to account for respiratory motion, a navigator was employed in the form of a single gradient-echo projection readout, located at the diaphragm along the inferior-superior direction. Prior to each transverse imaging slice of the spin-echo EPI based readouts, navigator and fat suppression were incorporated. Motion data was obtained from the navigator and transmitted back to the sequence, allowing real-time adjustments to slice positioning. The sinc-VSI without velocity-selective gradients during the control condition but with velocity-selective gradients along all three directions during labeling was chosen for the VSASL. The VSASL was compared with pseudo-continuous ASL (pCASL) methods, which selectively tagged the moving spins using a tagging plane placed at the portal vein and hepatic artery. The motion caused by respiratory activity was effectively computed using the navigator signal. The coefficients of variation (CoV) of average liver voxel in NAV were significantly decreased when compared to breath-hold (BH), with an average reduction of 29.4 ± 18.44% for control images, and 29.89 ± 20.83% for label images (p < 0.001). The resulting maps of normalized ASL signal (normalized to M0) showed significantly higher perfusion weightings in the NAV-compensated VSASL, when compared to the NAV-compensated pCASL techniques. This study demonstrates the feasibility of using a navigator-based prospective motion compensation technique in conjunction with VSASL for the measurement of liver perfusion without the use of contrast agents while allowing for free-breathing.