Yoshihito Suda

Dr. Yoshihito Suda


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2022 in Bone & Joint Open
Verified
Journal Article
Open access
Takafumi HiranakaTakafumi Hiranaka
Takafumi Hiranaka
YSYoshihito Suda
Yoshihito Suda
ASAkira Saitoh
Akira Saitoh
ATAtsuki Tanaka
Atsuki Tanaka
AAAkihiko Arimoto
Akihiko Arimoto
KOKoji Okamoto
Koji Okamoto
The kinematic alignment (KA) approach to total knee arthroplasty (TKA) has recently increased in popularity. Accordingly, a number of derivatives have arisen and have caused confusion. Clarification is therefore needed for a better understanding of KA-TKA. Calipered (or true, pure) KA is performed by cutting the bone parallel to the articular surface, compensating for cartilage wear. In soft-tissue respecting KA , the tibial cutting surface is decided parallel to the femoral cutting surface (or trial component) with in-line traction. These approaches are categorized as unrestricted KA because there is no consideration of leg alignment or component orientation. Restricted KA is an approach where the periarthritic joint surface is replicated within a safe range, due to concerns about extreme alignments that have been considered ‘alignment outliers’ in the neutral mechanical alignment approach. More recently, functional alignment and inverse kinematic alignment have been advocated, where bone cuts are made following intraoperative planning, using intraoperative measurements acquired with computer assistance to fulfill good coordination of soft-tissue balance and alignment. The KA-TKA approach aims to restore the patients’ own harmony of three knee elements (morphology, soft-tissue balance, and alignment) and eventually the patients’ own kinematics. The respective approaches start from different points corresponding to one of the elements, yet each aim for the same goal, although the existing implants and techniques have not yet perfectly fulfilled that goal.

1 October 2022 in The Bone & Joint Journal
Verified
Journal Article
Closed access
YSYoshihito Suda
Yoshihito Suda
Takafumi HiranakaTakafumi Hiranaka
Takafumi Hiranaka
TKTomoyuki Kamenaga
Tomoyuki Kamenaga
MKMotoki Koide
Motoki Koide
TFTakaaki Fujishiro
Takaaki Fujishiro
TMTomoyuki Matsumoto
Tomoyuki Matsumoto
Aims: A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. Methods: This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. Results: Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). Conclusion: In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture. Cite this article: Bone Joint J 2022;104-B(10):1118–1125.

13 January 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TKTomoyuki Kamenaga
Tomoyuki Kamenaga
Takafumi HiranakaTakafumi Hiranaka
Takafumi Hiranaka
YSYoshihito Suda
Yoshihito Suda
TFTakaaki Fujishiro
Takaaki Fujishiro
KOKoji Okamoto
Koji Okamoto
TMTomoyuki Matsumoto
Tomoyuki Matsumoto
A short keel-cortex distance (KCD), especially to the posterior cortex, is a potential risk factor for tibial plateau fracture after Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). This study aimed to evaluate the effect of tibial component alignment in the coronal plane and tibial proximal morphology on the KCD. Included in this study were 51 patients scheduled for primary Oxford medial unicompartmental knee arthroplasty (UKA). The anterior and posterior KCD were preoperatively assessed using 3D simulation software with the component set perpendicular to the tibial mechanical axis (neutral), 3° valgus, 3° varus, and 6° varus, relative to neutral alignment. We evaluated the existence of overhanging medial tibial condyle where the medial eminence line, the line including the medial tibial eminence parallel to the tibial axis, passes outside of the tibial shaft. In all component alignments, patients with a medial overhanging condyle had significantly shorter posterior KCD than those without. In patients with a medial overhanging condyle, the posterior KCD significantly increased when the tibial component was placed in 3° varus (4.6 ± 1.5 mm, P = 0.003 vs neutral, P < 0.001 vs 3° valgus) and 6° varus (5.0 ± 1.4 mm, P < 0.001 vs neutral, P < 0.001 vs 3° valgus) compared with in neutral (3.5 ± 1.9 mm) or 3° valgus (2.8 ± 1.8 mm). In OUKA, varus implantation increased the KCD. This could potentially decrease the risk of fracture, even in knees with the overhanging medial condyle. Conversely, valgus implantation of the tibial component shortened the KCD, and should therefore be avoided.

1 April 2022 in Bone & Joint Research
Verified
Journal Article
Open access
Takafumi HiranakaTakafumi Hiranaka
Takafumi Hiranaka
YSYoshihito Suda
Yoshihito Suda
ASAkira Saitoh
Akira Saitoh
MKMotoki Koide
Motoki Koide
ATAtsuki Tanaka
Atsuki Tanaka
KOKoji Okamoto
Koji Okamoto
The British Editorial Society of Bone & Joint Surgery

28 August 2023 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
KIKemmei Ikuta
Kemmei Ikuta
SHShinya Hayashi
Shinya Hayashi
KKKenichi Kikuchi
Kenichi Kikuchi
MFMasahiro Fujita
Masahiro Fujita
KAKensuke Anjiki
Kensuke Anjiki
RKRyosuke Kuroda
Ryosuke Kuroda

11 October 2019 in Annals of Medicine & Surgery
Verified
Journal Article
Open access
PDF file
YSYoshihito Suda
Yoshihito Suda
KOKeisuke Oe
Keisuke Oe
TFTomoaki Fukui
Tomoaki Fukui
YMYutaka Mifune
Yutaka Mifune
AIAtsuyuki Inui
Atsuyuki Inui
Takahiro NiikuraTakahiro Niikura
Takahiro Niikura
Introduction: We treated two cases of humeral shaft nonunion by minimally invasive plate osteosynthesis (MIPO) without autogenous bone grafting. Presntation of case Case 1: An osteosynthesis with intramedullary nailing (IMN) was performed on a 17-year-old female for a humeral shaft fracture at another hospital; however, bony union was not obtained. We removed the nail and screws, then performed MIPO without autogenous bone grafting. At the final follow-up of 4 years after the surgery, she had obtained full range of motion.Case 2: Osteosynthesis with Rush pins had been performed in a 73-year-old female for a humeral shaft fracture at another hospital. Five months later, a revision surgery using IMN was performed at the same hospital; however, this led to nonunion. We removed the IMN and performed MIPO without autogenous bone grafting. At the final follow-up 2 years after surgery, she had obtained full range of motion. Discussion: The cause of nonunion is the lack of mechanical instability and/or biological activity. In these cases, from the findings of radiography and bone scintigraphy, mechanical instability was thought to be the primary cause; therefore, in order to enhance stability, we used a locking plate. Because we can see that these cases are biologically active, we decided not to use bone grafting. Both our cases successfully achieved bony union and excellent functional recovery using this method. Conclusion: We performed MIPO without exposure of the nonunion site and autogenous bone grafting in two cases of humeral shaft nonunion, and obtained successful clinical outcomes.