Bone defects may occur because of severe trauma, nonunion, infection, or tumor resection. However, treatments for bone defects are often difficult and have not been fully established yet. We previously designed an efficient system of topical cutaneous application of carbon dioxide (CO2) using a novel hydrogel, which facilitates CO2 absorption through the skin into the deep area within a limb. In this study, the effect of topical cutaneous application of CO2 on bone healing was investigated using a rat femoral defect model. In this basic research study, an in vivo bone defect model, fixed with an external fixator, was created using a rat femur. The affected limb was shaved, and CO2 was applied for 20 min/day, 5 days/week. In the control animals, CO2 gas was replaced with air. Radiographic, histological, biomechanical, and genetic assessments were performed to evaluate bone healing. Radiographically, bone healing rate was significantly higher in the CO2 group than in the control group at 4 weeks (18.2% vs. 72.7%). The degree of bone healing scored using the histopathological Allen grading system was significantly higher in the CO2 group than in the control group at 2 weeks (1.389 ± 0.334 vs. 1.944 ± 0.375). The ultimate stress, extrinsic stiffness, and failure energy were significantly greater in the CO2 group than in the control group at 4 weeks (3.2 ± 0.8% vs. 38.1 ± 4.8%, 0.6 ± 0.3% vs. 41.5 ± 12.2%, 2.6 ± 0.8% vs. 24.7 ± 5.9%, respectively.). The volumetric bone mineral density of the callus in micro-computed tomography analysis was significantly higher in the CO2 group than in the control group at 4 weeks (180.9 ± 43.0 mg/cm3 vs. 247.9 ± 49.9 mg/cm3). Gene expression of vascular endothelial growth factor in the CO2 group was significantly greater than that in the control group at 3 weeks (0.617 ± 0.240 vs. 2.213 ± 0.387). Topical cutaneous application of CO2 accelerated bone healing in a rat femoral defect model. CO2 application can be a novel and useful therapy for accelerating bone healing in bone defects; further research on its efficacy in humans is warranted.
1 January 2018 in International Journal of Surgery Case Reports
Introduction: Osteopetrosis is a skeletal disorder characterized by increased osteodensity and a remodeling defect. The fragility of dense sclerotic bones may lead to an increased incidence of fractures. Although internal fixation can be performed, technical challenges may be experienced because of the increased bone density. Complications such as delayed union, nonunion, or implant failure may occur postoperatively. Presentation of case: We describe a patient with autosomal-dominant osteopetrosis type 2 who suffered a shaft fracture below a plate of his right femur. We performed osteosynthesis with a single locking plate. Union was delayed, and plate breakage occurred along with nonunion of the fracture. The nonunion was addressed using double locking plates, which secured fixation and allowed complete fracture healing. Discussion: There were three reasons of nonunion in our case. First, we left gaps between the fragments. Second, we used mainly cerclage wires, rather than screws, for plate fixation, which led to inadequate stability. Third, the patient was large (height 167 cm, weight 93.1 kg), so the single plate provided insufficient fixing force. We then used double locking plates and attained stronger internal fixation with complete fracture healing. Conclusion: Double plating with locking plates may be an effective treatment option for femoral fractures in patients with osteopetrosis. Highlights:
Background: Rad is the prototypic member of a subfamily of Ras-related small G-proteins and is highly expressed in the skeletal muscle of patients with type II diabetes. Our previous microarray analysis suggested that Rad may mediate fracture nonunion development. Thus, the present study used rat experimental models to investigate and compare the gene and protein expression patterns of both Rad and Rem1, another RGK subfamily member, in nonunions and standard healing fractures. Methods: Standard healing fractures and nonunions (produced via periosteal cauterization at the fracture site) were created in the femurs of 3-month-old male Sprague-Dawley rats. At post-fracture days 7, 14, 21, and 28, the fracture callus and fibrous tissue from the standard healing fractures and nonunions, respectively, were harvested and screened (via real-time PCR) for Rad and Rem1 expression. The immunolocalization of both encoded proteins was analyzed at post-fracture days 14 and 21. At the same time points, hematoxylin and eosin staining was performed to identify the detailed tissue structures. Results: Results of real-time PCR analysis showed that Rad expression increased significantly in the nonunions, compared to that in the standard healing fractures, at post-fracture days 14, 21, and 28. Conversely, immunohistochemical analysis revealed the immunolocalization of Rad to be similar to that of Rem1 in both fracture types at post-fracture days 14 and 21. Conclusions: Rad may mediate nonunion development, and thus, may be a promising therapeutic target to treat these injuries.
When visualizing biological activity at nonunion sites by the radioisotopes, gamma rays are more attenuated if metal implants are placed in the bone. However, the effects of various implant types and their placement on gamma ray attenuation in quantitative evaluation remain unknown. To elucidate these effects, we created a phantom that simulated the nonunion of the femur in this study. The count of gamma rays was measured by single-photon emission computed tomography/computed tomography (SPECT/CT) while considering CT-based attenuation correction (CTAC), metal implant placement, type (intramedullary nail or plate), and position. The count differed significantly with and without CTAC and with and without implants (both types) under CTAC. Significantly different counts were observed between the intramedullary nail and plate placed contralaterally to the lesion (i.e., non-lesion side). No significant difference was observed between the intramedullary nail and plate on the lesion side or between plates on the non-lesion and lesion sides. The measured standardized uptake value (SUV) was closer to the true SUV with CTAC than without. Moreover, the count was higher with implants than without. However, even with implants, it was lower than the actual count, indicating the absence of overcorrection. Implant type and position do not seem to influence the count.
Introduction: We treated two cases of humeral shaft nonunion by minimally invasive plate osteosynthesis (MIPO) without autogenous bone grafting. Presntation of case Case 1: An osteosynthesis with intramedullary nailing (IMN) was performed on a 17-year-old female for a humeral shaft fracture at another hospital; however, bony union was not obtained. We removed the nail and screws, then performed MIPO without autogenous bone grafting. At the final follow-up of 4 years after the surgery, she had obtained full range of motion.Case 2: Osteosynthesis with Rush pins had been performed in a 73-year-old female for a humeral shaft fracture at another hospital. Five months later, a revision surgery using IMN was performed at the same hospital; however, this led to nonunion. We removed the IMN and performed MIPO without autogenous bone grafting. At the final follow-up 2 years after surgery, she had obtained full range of motion. Discussion: The cause of nonunion is the lack of mechanical instability and/or biological activity. In these cases, from the findings of radiography and bone scintigraphy, mechanical instability was thought to be the primary cause; therefore, in order to enhance stability, we used a locking plate. Because we can see that these cases are biologically active, we decided not to use bone grafting. Both our cases successfully achieved bony union and excellent functional recovery using this method. Conclusion: We performed MIPO without exposure of the nonunion site and autogenous bone grafting in two cases of humeral shaft nonunion, and obtained successful clinical outcomes.
Background/Objectives: The aim of this study was to evaluate changes in bone mineral density (BMD) around the stem in elderly patients with femoral neck fractures who underwent hemiarthroplasty using a collared and full hydroxyapatite coated cementless stem, as assessed using the Dorr classification and with anti-osteoporosis drug intervention. Methods: This study followed 85 older patients with femoral neck fractures classified by Dorr’s classification. We measured their BMD around the stem using dual-energy X-ray absorptiometry according to Gruen 7 zones classification and clinical scores. We compared the rate of BMD change based on Dorr’s classification and clinical scores. We also investigated the effect of osteoporosis treatment interventions on the rate of BMD change. The study followed up with the patients for one year after surgery. Results: After excluding patients with missing data, 40 patients were included in the analysis. The rate of change in BMD in zone 2 was significantly reduced in Dorr type C compared to Dorr type B. Clinical scores did not significantly differ between the three groups. Regarding the association between osteoporosis treatment and the rate of BMD change, the pre-injury intervention group had a significantly suppressed decline in the rate of BMD change in zones 1 and 7 compared to the post-injury intervention and no-intervention groups. Conclusions: Careful follow-up examination is crucial when performing hemiarthroplasty in patients with Dorr type C femoral neck fractures because the rate of BMD change may decline postoperatively. Pre-injury osteoporosis intervention therapy may suppress BMD loss around the stem.