Anna L. Falkowski

Dr. Anna L. Falkowski

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2016 in Investigative Radiology
Verified
Journal Article
Closed access
AEAndré Euler
André Euler
APAnushri Parakh
Anushri Parakh
AFAnna L. Falkowski
Anna L. Falkowski
SMSebastian Manneck
Sebastian Manneck
DDDavid Dashti
David Dashti
SSSebastian T. Schindera
Sebastian T. Schindera
Objective: The aim of this study was to investigate the image quality, radiation dose, and accuracy of virtual noncontrast images and iodine quantification of split-filter dual-energy computed tomography (CT) using a single x-ray source in a phantom and patient study. Materials and Methods: In a phantom study, objective image quality and accuracy of iodine quantification were evaluated for the split-filter dual-energy mode using a tin and gold filter. In a patient study, objective image quality and radiation dose were compared in thoracoabdominal CT of 50 patients between the standard single-energy and split-filter dual-energy mode. The radiation dose was estimated by size-specific dose estimate. To evaluate the accuracy of virtual noncontrast imaging, attenuation measurements in the liver, spleen, and muscle were compared between a true noncontrast premonitoring scan and the virtual noncontrast images of the dual-energy scans. Descriptive statistics and the Mann-Whitney U test were used. Results: In the phantom study, differences between the real and measured iodine concentration ranged from 2.2% to 21.4%. In the patient study, the single-energy and dual-energy protocols resulted in similar image noise (7.4 vs 7.1 HU, respectively; P = 0.43) and parenchymal contrast-to-noise ratio (CNR) values for the liver (29.2 vs 28.5, respectively; P = 0.88). However, the vascular CNR value for the single-energy protocol was significantly higher than for the dual-energy protocol (10.0 vs 7.1, respectively; P = 0.006). The difference in the measured attenuation between the true and the virtual noncontrast images ranged from 3.1 to 6.7 HU. The size-specific dose estimate of the dual-energy protocol was, on average, 17% lower than that of the single-energy protocol (11.7 vs 9.7 mGy, respectively; P = 0.008). Conclusions: Split-filter dual-energy compared with single-energy CT results in similar objective image noise in addition to dual-energy capabilities at 17% lower radiation dose. Because of beam hardening, split-filter dual-energy can lead to decreased CNR values of iodinated structures.

22 May 2013 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
HRHelmut Rasch
Helmut Rasch
AFAnna L. Falkowski
Anna L. Falkowski
FFFlavio Forrer
Flavio Forrer
JHJohann Henckel
Johann Henckel
MHMichael T. Hirschmann
Michael T. Hirschmann

1 February 2020 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
AFAnna L. Falkowski
Anna L. Falkowski
JJJon A. Jacobson
Jon A. Jacobson
MFMichael T. Freehill
Michael T. Freehill
VKVivek Kalia
Vivek Kalia
Background: Portable ultrasound machines are now common, used for point-of-care applications and needle guidance for percutaneous procedures; however, the effectiveness of portable ultrasound in evaluation of the musculoskeletal system has not been fully assessed. Purpose: To prospectively evaluate the use of portable hand-held ultrasound in comparison with conventional cart-based ultrasound in evaluation of the musculoskeletal system. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: In this institutional review board–approved, prospective study, 100 consecutive patients with informed consent were imaged through use of both portable and cart-based ultrasound equipment using 12-5 MHz linear transducers. Agreement in ultrasound diagnosis was documented along with expected clinical changes in management if there was disagreement (definitely no, probably no, uncertain, probably yes, definitely yes). Imaging details of disagreement cases were recorded, and descriptive statistics were calculated. Results: There were 42 male and 58 female patients (mean ± SD age, 53 ± 13 years) imaged over a time period of 20 months. Anatomic areas scanned were the shoulder (n = 30), elbow (n = 11), hand and wrist (n = 15), hip (n = 10), knee (n = 11), foot and ankle (n = 12), and others (n = 11). Scanning with conventional ultrasound revealed abnormality in 92% of patients. Agreement in diagnosis made between portable versus cart-based ultrasound was found in 65% of patients. In the 35% of patients with discordant results, the change in diagnosis resulted in no change in clinical management in 46%, probably no change in 29%, uncertain change in 14%, probable change in 11%, and definite change in 0%. The diagnoses changing management (4%; 4/100) included nondetection of a satellite nodule (n = 1), ganglion cyst (n = 1), hernia (n = 1), and underestimated tendon tear (n = 1). Conclusion: When compared with conventional cart-based ultrasound, a musculoskeletal diagnosis using portable hand-held ultrasound was concordant or was discordant without clinical relevance in 96% (96/100) of patients. Knowledge of benefits and limitations of portable hand-held ultrasound will help determine areas where specific types of ultrasound equipment can be used.

19 February 2018 in European Radiology
Verified
Journal Article
Closed access
PDF file
AEAndré Euler
André Euler
MOMarkus Obmann
Markus Obmann
ZSZsolt Szucs-Farkas
Zsolt Szucs-Farkas
AMAchille Mileto
Achille Mileto
CZCaroline Zaehringer
Caroline Zaehringer
SSSebastian T. Schindera
Sebastian T. Schindera

31 March 2020 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
MMM. Murer
M. Murer
AFAnna L. Falkowski
Anna L. Falkowski
AHA. Hirschmann
A. Hirschmann
FAF. Amsler
F. Amsler
MHMichael T. Hirschmann
Michael T. Hirschmann

1 January 2016 in Radiology
Verified
Journal Article
Closed access
MDMilos Dordevic
Milos Dordevic
MHMichael T. Hirschmann
Michael T. Hirschmann
JRJan Rechsteiner
Jan Rechsteiner
AFAnna L. Falkowski
Anna L. Falkowski
ETEnrique Testa
Enrique Testa
AHAnna Hirschmann
Anna Hirschmann
Chondral lesions with osseous involvement represented by grades 3 and 4 showed higher SPECT/CT bone tracer uptake than those without osseous involvement (grades 1 and 2). PurposeTo evaluate the correlation of bone tracer uptake as determined with single photon emission computed tomography (SPECT)/computed tomography (CT) and the size and severity of chondral lesions detected with magnetic resonance (MR) imaging of the knee.Materials and MethodsMR imaging and SPECT/CT images of 63 knee joints in 63 patients (mean age ± standard deviation, 49.2 years ± 12.7) with chondral or osteochondral lesions were prospectively collected and retrospectively analyzed after approval by the ethics committee. Chondral lesions were graded on MR images by using a modified Noyes grading scale (grade 0, intact; grade 1, fibrillations; grade 2, 50% defect; and grade 4, grade three plus subchondral changes) and measured in two dimensions. Technetium 99m hydroxymethane diphosphonate SPECT/CT bone tracer uptake was volumetrically quantified by using validated software. Maximum values of each subchondral area (patellofemoral or medial and lateral femorotibial) were quantified, ...