Lindsey Van Yper

Dr. Lindsey Van Yper

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2021 in Neurophotonics
Verified
Journal Article
Open access
PDF file
RLRobert Luke
Robert Luke
Eric LarsonEric Larson
Eric Larson
MSMaureen J. Shader
Maureen J. Shader
HIHamish Innes-Brown
Hamish Innes-Brown
LYLindsey Van Yper
Lindsey Van Yper
DMDavid McAlpine
David McAlpine
Functional near-infrared spectroscopy (fNIRS) is an increasingly popular technique1 employed to investigate auditory-cortical function, and provides a unique set of qualities that make it ideal for auditory research. fNIRS devices are typically very quiet compared with functional magnetic resonance imaging (fMRI) with which it shares a similar biologically generated signal. fNIRS is unaffected by electrical or magnetic interference from hearing devices such as cochlear implants or hearing aids, all of which are either contra-indicated or generate large artifacts in fMRI and in electro- and magneto-encephalography (EEG and MEG, respectively). fNIRS devices are generally relatively portable and do not require participants or patients to be isolated in a shielded chamber or to have their head-position fixed, making it well suited for use in low- or non-compliant groups, including children, the elderly, and the cognitively impaired. Therefore, it provides an ideal imaging modality for clinical applications.

1 April 2015 in Clinical Neurophysiology
Verified
Journal Article
Closed access
LYLindsey Van Yper
Lindsey Van Yper
KVKatrien Vermeire
Katrien Vermeire
EVEddy F.J. De Vel
Eddy F.J. De Vel
RBRolf-Dieter Battmer
Rolf-Dieter Battmer
IDIngeborg J.M. Dhooge
Ingeborg J.M. Dhooge

1 July 2016 in Ear & Hearing
Verified
Journal Article
Closed access
LYLindsey Van Yper
Lindsey Van Yper
KVKatrien Vermeire
Katrien Vermeire
EVEddy F. J. De Vel
Eddy F. J. De Vel
ABAndy J. Beynon
Andy J. Beynon
IDIngeborg J. M. Dhooge
Ingeborg J. M. Dhooge
Age-related hearing loss hampers the ability to understand speech in adverse listening conditions. This is attributed to a complex interaction of changes in the peripheral and central auditory system. One aspect that may deteriorate across the lifespan is binaural interaction. The present study investigates binaural interaction at the level of the auditory brainstem. It is hypothesized that brainstem binaural interaction deteriorates with advancing age. Forty-two subjects of various age participated in the study. Auditory brainstem responses (ABRs) were recorded using clicks and 500 Hz tone-bursts. ABRs were elicited by monaural right, monaural left, and binaural stimulation. Binaural interaction was investigated in two ways. First, grand averages of the binaural interaction component were computed for each age group. Second, wave V characteristics of the binaural ABR were compared with those of the summed left and right ABRs. Binaural interaction in the click ABR was demonstrated by shorter latencies and smaller amplitudes in the binaural compared with the summed monaural responses. For 500 Hz tone-burst ABR, no latency differences were found. However, amplitudes were significantly smaller in the binaural than summed monaural condition. An age-effect was found for 500 Hz tone-burst, but not for click ABR. Brainstem binaural interaction seems to decline with age. Interestingly, these changes seem to be stimulus-dependent.

25 April 2021 in MethodsX
Verified
Journal Article
Open access
JUJaime A. Undurraga
Jaime A. Undurraga
LYLindsey Van Yper
Lindsey Van Yper
MBManohar Bance
Manohar Bance
DMDavid McAlpine
David McAlpine
DVDeborah Vickers
Deborah Vickers
Electroencephography (EEG) recordings from CI listeners are contaminated by electrical artefacts that make it difficult to extract neural responses. Previously, we have removed these artefacts by means of interpolation and spatial filtering. However, the extent to which this method can effectively reduce electrical artefacts has not been fully investigated. Here, we assessed the effectiveness of interpolation and spatial filtering to remove electrical artefacts using recordings from a human head specimen implanted with a CI. • Electrical artefacts were obtained using amplitude-modulated (AM'ed) pulse trains presented at several pulse rates (100-to-902 pps) or using high rate pulse trains (902 pps) in which either a pair of electrodes or AM frequencies alternated periodically at a rate of 1Hz. • By adding auditory change complex (ACC), auditory steady-state response (ASSR), or auditory change following response (AC-FR) template waveforms to the contaminated recordings, we show that interpolation allows for effective artefact removal for pulse rates below 400 pps whilst interpolation and spatial filtering are effective at higher pulse rates, with minimal distortions for ACC and AC-FR, and with a degree of amplitude- and phase-distortions for ASSR. • Recordings from CI listeners agreed with simulations, demonstrating that reliable responses can be recovered.

28 August 2019 in International Journal of Audiology
Verified
Journal Article
Closed access
LYLindsey Van Yper
Lindsey Van Yper
IDIngeborg J. M. Dhooge
Ingeborg J. M. Dhooge
KVKatrien Vermeire
Katrien Vermeire
EVEddy F. J. De Vel
Eddy F. J. De Vel
ABAndy J. Beynon
Andy J. Beynon
Objective: Bimodal listeners vary in the amount of benefit they receive from wearing the contralateral hearing aid. This may partially depend on the listener’s auditory processing capacities. The current study explores whether the P300 event-related potential can provide insight into the mechanisms underlying the benefits of wearing a contralateral hearing aid. Design: P300s were recorded using an oddball paradigm with 500 and 250 Hz tone-bursts as standard and deviant stimuli, respectively. Subjects counted the number of deviants – a measure of performance. N2b latencies, P300 latencies, N2b-P300 amplitudes, and performance were assessed during CI-only and bimodal listening. Study sample: Five bimodal listeners. Results: P300s were present in four subjects. Amplitudes were larger during bimodal listening (bimodal: 22.3 ± 4.83 µV, CI-only: 13.1 ± 3.86 µV). Both N2b and P300 latencies were shorter during bimodal (N2b: 265 ± 20.0 ms, P300: 551 ± 129.4 ms) than CI-only listening (N2b: 326 ± 42.2 ms, P300: 402 ± 38.4 ms). While performance often reached ceiling level, the difference between the standard and deviant was generally more salient during bimodal listening. Conclusions: This study provides a proof-of-concept, suggesting that P300s may provide insight into benefits that are not always measurable with behavioural tasks.

22 December 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
RLRobert Luke
Robert Luke
Eric LarsonEric Larson
Eric Larson
MSMaureen J Shader
Maureen J Shader
HIHamish Innes-Brown
Hamish Innes-Brown
LYLindsey Van Yper
Lindsey Van Yper
DMDavid McAlpine
David McAlpine
Significance fNIRS is an increasingly popular tool in auditory research, but the range of analysis procedures employed across studies complicates interpretation of data. Aim To assess the impact of different analysis procedures on the morphology, detection, and lateralization of auditory responses in fNIRS. Specifically, whether averaging or GLM-based analyses generate different experimental conclusions, when applied to a block-protocol design. The impact of parameter selection of GLMs on detecting auditory-evoked responses was also quantified. Approach 17 listeners were exposed to three commonly employed auditory stimuli: noise, speech, and silence. A block design was employed, comprising sounds of 5-s duration, and 10–20 s silent intervals. Results Both analysis procedures generated similar response morphologies and amplitude estimates, and both also indicated responses to speech to be significantly greater than to noise and silence. Neither approach indicated a significant effect of brain hemisphere on responses to speech. Methods to correct for systemic hemodynamic responses using short channels improved detection at the individual level. Conclusions Consistent with theoretical considerations, simulations, and other experimental domains, GLM and averaging analyses generate the same group-level experimental conclusions. We release this dataset publicly for use in future development and optimization of algorithms.