Maureen J. Shader

Maureen J. Shader

Auto-generated profile, based on publicly available information

Maureen J. Shader

Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2021 in Neurophotonics
Verified
Journal Article
Open access
PDF file
RLRobert Luke
Robert Luke
Eric LarsonEric Larson
Eric Larson
MSMaureen J. Shader
Maureen J. Shader
HIHamish Innes-Brown
Hamish Innes-Brown
LYLindsey Van Yper
Lindsey Van Yper
DMDavid McAlpine
David McAlpine
Functional near-infrared spectroscopy (fNIRS) is an increasingly popular technique1 employed to investigate auditory-cortical function, and provides a unique set of qualities that make it ideal for auditory research. fNIRS devices are typically very quiet compared with functional magnetic resonance imaging (fMRI) with which it shares a similar biologically generated signal. fNIRS is unaffected by electrical or magnetic interference from hearing devices such as cochlear implants or hearing aids, all of which are either contra-indicated or generate large artifacts in fMRI and in electro- and magneto-encephalography (EEG and MEG, respectively). fNIRS devices are generally relatively portable and do not require participants or patients to be isolated in a shielded chamber or to have their head-position fixed, making it well suited for use in low- or non-compliant groups, including children, the elderly, and the cognitively impaired. Therefore, it provides an ideal imaging modality for clinical applications.

4 August 2025 in Communications Biology
Verified
Journal Article
Open access
MYMeryem A. Yücel
Meryem A. Yücel
RLRobert Luke
Robert Luke
Rickson C. MesquitaRickson C. Mesquita
Rickson C. Mesquita
ALAlexander von Lühmann
Alexander von Lühmann
DMDavid M. A. Mehler
David M. A. Mehler
VZVit Zemanek
Vit Zemanek
As data analysis pipelines grow more complex in brain imaging research, understanding how methodological choices affect results is essential for ensuring reproducibility and transparency. This is especially relevant for functional Near-Infrared Spectroscopy (fNIRS), a rapidly growing technique for assessing brain function in naturalistic settings and across the lifespan, yet one that still lacks standardized analysis approaches. In the fNIRS Reproducibility Study Hub (FRESH) initiative, we asked 38 research teams worldwide to independently analyze the same two fNIRS datasets. Despite using different pipelines, nearly 80% of teams agreed on group-level results, particularly when hypotheses were strongly supported by literature. Teams with higher self-reported analysis confidence, which correlated with years of fNIRS experience, showed greater agreement. At the individual level, agreement was lower but improved with better data quality. The main sources of variability were related to how poor-quality data were handled, how responses were modeled, and how statistical analyses were conducted. These findings suggest that while flexible analytical tools are valuable, clearer methodological and reporting standards could greatly enhance reproducibility. By identifying key drivers of variability, this study highlights current challenges and offers direction for improving transparency and reliability in fNIRS research.

1 July 2021 in Hearing Research
Verified
Journal Article
Closed access
MSMaureen J. Shader
Maureen J. Shader
RLRobert Luke
Robert Luke
NGNathalie Gouailhardou
Nathalie Gouailhardou
CMColette M. McKay
Colette M. McKay

1 May 2020 in Ear & Hearing
Verified
Journal Article
Closed access
MSMaureen J. Shader
Maureen J. Shader
NNNicole Nguyen
Nicole Nguyen
MCMiranda Cleary
Miranda Cleary
RHRonna Hertzano
Ronna Hertzano
DEDavid J. Eisenman
David J. Eisenman
MGMatthew J. Goupell
Matthew J. Goupell
Objectives: Cochlear implants (CIs) are considered a safe and effective intervention for more severe degrees of hearing loss in adults of all ages. Although older CI users ≥65 years of age can obtain large benefits in speech understanding from a CI, there is a growing body of literature suggesting that older CI users may not perform as well as younger CI users. One reason for this potential age-related limitation could be that default CI stimulation settings are not optimal for older CI users. The goal of this study was to determine whether improvements in speech understanding were possible when CI users were programmed with nondefault stimulation rates and to determine whether lower-than-default stimulation rates improved older CI users’ speech understanding.Design: Sentence recognition was measured acutely using different stimulation rates in 37 CI users ranging in age from 22 to 87 years. Maps were created using rates of 500, 720, 900, and 1200 pulses per second (pps) for each subject. An additional map using a rate higher than 1200 pps was also created for individuals who used a higher rate in their clinical processors. Thus, the clinical rate of each subject was also tested, including non-default rates above 1200 pps for Cochlear users and higher rates consistent with the manufacturer defaults for subjects implanted with Advanced Bionics and Med-El devices. Speech understanding performance was evaluated at each stimulation rate using AzBio and Perceptually Robust English Sentence Test Open-set (PRESTO) sentence materials tested in quiet and in noise.Results: For Cochlear-brand users, speech understanding performance using non-default rates was slightly poorer when compared with the default rate (900 pps). However, this effect was offset somewhat by age, in which older subjects were able to maintain comparable performance using a 500-pps map compared with the default rate map when listening to the more difficult PRESTO sentence material. Advanced Bionics and Med-El users showed modest improvements in their overall performance using 720 pps compared with the default rate (>1200 pps). On the individual-subject level, 10 subjects (11 ears) showed a significant effect of stimulation rate, with 8 of those ears performing best with a lower-than-default rate.Conclusions: Results suggest that default stimulation rates are likely sufficient for many CI users, but some CI users at any age can benefit from a lower-than-default rate. Future work that provides experience with novel rates in everyday life has the potential to identify more individuals whose performance could be improved with changes to stimulation rate.

8 December 2021 in Neurophotonics
Verified
Journal Article
Open access
PDF file
RLRobert Luke
Robert Luke
MSMaureen J. Shader
Maureen J. Shader
DMDavid McAlpine
David McAlpine
The ability to explore and understand the brain requires the differentiation of signals that arise from the neural activity of interest from signals that are generated by other factors or non-neural processes. Neuroimaging techniques that estimate the concentration of oxygenated and/or deoxygenated hemoglobin within the cortical blood flow, including functional magnetic resonance imaging and functional near-infrared spectroscopy (fNIRS), are susceptible to disruptions from non-neural cardiovascular oscillations in the signal.1 For example, oscillations corresponding to heart rate (∼1  Hz) and respiratory rate (∼0.3  Hz) are present within the broad frequency spectrum of the measured signal and can be removed or reduced through filtering. Another cardiovascular component is Mayer waves, which are spontaneous oscillations in arterial blood pressure with a frequency of ∼0.1  Hz.2,3 Mayer waves are not easily removed from hemodynamic signatures of brain activity as they tend to occur on a time course often confounded with the frequency of a sensory task, for example, and/or the cortical hemodynamic response to that task.

1 January 2019 in Trends in Hearing
Verified
Journal Article
Open access
PDF file
ZXZilong Xie
Zilong Xie
CGCasey R. Gaskins
Casey R. Gaskins
MSMaureen J. Shader
Maureen J. Shader
SGSandra Gordon-Salant
Sandra Gordon-Salant
SASamira Anderson
Samira Anderson
MGMatthew Goupell
Matthew Goupell
Aging may limit speech understanding outcomes in cochlear-implant (CI) users. Here, we examined age-related declines in auditory temporal processing as a potential mechanism that underlies speech understanding deficits associated with aging in CI users. Auditory temporal processing was assessed with a categorization task for the words dish and ditch (i.e., identify each token as the word dish or ditch) on a continuum of speech tokens with varying silence duration (0 to 60 ms) prior to the final fricative. In Experiments 1 and 2, younger CI (YCI), middle-aged CI (MCI), and older CI (OCI) users participated in the categorization task across a range of presentation levels (25 to 85 dB). Relative to YCI, OCI required longer silence durations to identify ditch and exhibited reduced ability to distinguish the words dish and ditch (shallower slopes in the categorization function). Critically, we observed age-related performance differences only at higher presentation levels. This contrasted with findings from normal-hearing listeners in Experiment 3 that demonstrated age-related performance differences independent of presentation level. In summary, aging in CI users appears to degrade the ability to utilize brief temporal cues in word identification, particularly at high levels. Age-specific CI programming may potentially improve clinical outcomes for speech understanding performance by older CI listeners.