Giovanni Rubegni

Dr. Giovanni Rubegni

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Carlos Rocha-de-LossadaCarlos Rocha-de-Lossada
Carlos Rocha-de-Lossada
Cosimo MazzottaCosimo Mazzotta
Cosimo Mazzotta
Federico GabrielliFederico Gabrielli
Federico Gabrielli
FPFilomena Tiziana Papa
Filomena Tiziana Papa
CHCarmen Gomez Huertas
Carmen Gomez Huertas
Davide BorroniDavide Borroni
Davide Borroni
In the field of Ophthalmology, the mNGS 16S rRNA sequencing method of studying the microbiota and ocular microbiome is gaining more and more weight in the scientific community. This study aims to characterize the ocular microbiota of patients diagnosed with keratoconus who have not undergone any prior surgical treatment using the mNGS 16S rRNA sequencing method. Samples of naïve keratoconus patients were collected with an eNAT with 1 mL of Liquid Amies Medium (Copan Brescia, Italy), and DNA was extracted and analyzed with 16S NGS. The microbiota analysis showed a relative abundance of microorganisms at the phylum level in each sample collected from 38 patients with KC and 167 healthy controls. A comparison between healthy control and keratoconus samples identified two genera unique to keratoconus, Pelomonas and Ralstonia. Our findings suggest that alterations in the microbiota may play a role in the complex scenario of KC development.

14 August 2024 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
MOM. Orione
M. Orione
GRGiovanni Rubegni
Giovanni Rubegni
RTR. Tartaro
R. Tartaro
AAA. Alberghina
A. Alberghina
MFM. Fallico
M. Fallico
TAT. Avitabile
T. Avitabile
Purpose: This paper explores the application of Apple Vision Pro in ophthalmic surgery, assessing its potential benefits in providing real-time imaging overlay, surgical guidance, and collaborative opportunities. Materials and method: The device was worn by 10 ophthalmic surgeons during eyelid malposition surgery. All surgeons performed the entire surgery while wearing the visor. At the end of procedure, all operators had to rate Apple Vision Pro visor according to 10 specific item and system usability scale (SUS) questionnaire. Results: The surgeons used the Apple Vision Pro during the entire procedure, and the results were positive, with high ratings for practicality, freedom of movement, integration into workflow, and learning. All surgeons rated the Apple Vision Pro above 85/100 in the SUS. Conclusion: The incorporation of Apple Vision Pro in oculoplastic surgery offers several advantages, including improved visualization, enhanced precision, and streamlined communication among surgical teams. According to our preliminary results Apple Vision Pro could represents a valuable tool in ophthalmic surgery, with implications for enhancing surgical techniques and advancing XR research in the surgical field.

8 February 2024 in Medicina
Verified
Journal Article
Open access
PDF file
Caterina GaglianoCaterina Gagliano
Caterina Gagliano
Marco ZeppieriMarco Zeppieri
Marco Zeppieri
ALAntonio Longo
Antonio Longo
GRGiovanni Rubegni
Giovanni Rubegni
RARoberta Amato
Roberta Amato
FDFabiana D’Esposito
Fabiana D’Esposito
Background and Objectives: Dry eye disease (DED) affects 5–50% of the global population and deeply influences everyday life activities. This study compared the efficacy, tolerability, and safety of novel Respilac artificial tears containing lipidure and hypromellose (HPMC) with the widely used Nextal artificial tears, which are also HPMC-based, for the treatment of moderate DED in contact lenses (CL) wearers. Materials and Methods: In a prospective, single-center, randomized investigation, 30 patients aged ≥18 years, diagnosed with moderate DED, and wearing CL were randomly assigned to the Respilac (n = 15) or Nextal group (n = 15). Patients self-administrated one drop of Respilac or Nextal in both eyes three times daily for 21 days. Changes in the endpoint (visual analogue scale (VAS) score for ocular tolerability, symptom assessment in dry eye (SANDE) score, non-invasive first break-up time (NIF-BUT) results, tear analysis value, meibography results, and CL tolerability results were assessed, comparing treatment groups and time-point evaluations. Adverse events (AEs) were also recorded and evaluated. Results: VAS scores decreased with time (p < 0.001) in both groups, showing no statistically significant difference among them (p = 0.13). Improvements were also detected from screening to end-of-treatment, which were indicated by the SANDE scores for severity and frequency (p < 0.001) and by tear analysis results (p < 0.001) with no observed difference between the Nextal and Respilac arms. NIF-BUT, meibography, and CL tolerability values were shown to be non-significantly affected by treatment and time. There were no AEs detected in this study cohort. Conclusions: Respilac was confirmed to be effective, safe, and well-tolerated. Lipidure-based ophthalmic solution was shown not to be inferior to the currently used Nextal, however, showing improvements in DED symptoms. Within the existing literature, our study is one of the first to report that MPC plus HPMC-containing eye drops are an effective option for the treatment of moderate dry eye disease and desiccation damage prevention in contact lens wearers.

22 April 2024 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
GRGiovanni Rubegni
Giovanni Rubegni
ACAlessandra Cartocci
Alessandra Cartocci
LTLinda Tognetti
Linda Tognetti
GTGianmarco Tosi
Gianmarco Tosi
MSMassimiliano Salfi
Massimiliano Salfi
TATeresio Avitabile
Teresio Avitabile
Purpose: To describe and validate a 3D-printed adapter tool which could be used with either a slit lamp or a condensing lens, interchangeable between devices through magnetic fastening, in order to provide physicians a quick, easy and effective method of obtaining clinical photos. Materials and Methods: Three specialists, with at least 4-year experience in ophthalmology, gave a rate of image quality obtained by our device and the diagnostic confidence grade. The 3 specialists conducted each 13 or 14 examinations with the smartphone and magnetic adapter. At the end of evaluation, they rated with the Likert scale the ease of use of the device in obtaining clinical images of the anterior segment and ocular fundus respectively. Results: Data of quality perception and confidence demonstrated high values not dissimilar to the “de visu” eye examination. Moreover the instrument we designed turned out to be very user friendly. Conclusion: Our adapter coupled with a modern smartphone was able to obtain 4k images and videos of anterior segment, central and peripheral fundus, in an easy and inexpensive way.

27 February 2025 in Cancers
Verified
Journal Article
Open access
PDF file
ECElisa Cinotti
Elisa Cinotti
MDMartina D'Onghia
Martina D'Onghia
ACAlessandra Cartocci
Alessandra Cartocci
SCSofia Lo Conte
Sofia Lo Conte
LBLorenzo Barbarossa
Lorenzo Barbarossa
PRPietro Rubegni
Pietro Rubegni
Background/Objectives: Basal cell carcinoma (BCC) is the most common malignancy, characterised by local invasiveness and the potential for tissue destruction. Diagnosing BCC can be challenging, particularly for less experienced dermatologists. Line-field confocal optical coherence tomography (LC-OCT), a new noninvasive optical technique, has become increasingly useful in clinical practice, allowing in vivo imaging at cellular resolution. This study aimed to evaluate the impact of a 1 h structured training session on the ability of dermatology residents to diagnose BCC using LC-OCT. Methods: Eight dermatology residents with different levels of LC-OCT experience (no experienced and low experience in LC-OCT) participated alongside an expert dermatologist as a benchmark. Overall, participants evaluated 40 histopathologically confirmed lesions (20 BCC, 20 non-BCC) before and after training, with and without the inclusion of dermoscopic images. Results: We observed a significant improvement in diagnostic accuracy post-training, especially among inexperienced users, with a 20% reduction in false negatives and a 35% reduction in false positives. When the dermoscopic images were included, further improvements were noted, with the accuracy increasing by an additional 5%. The overall diagnostic rate for inexperienced readers increased from 48% to 76% after training and to 81% with the addition of dermoscopic images in the course. Conclusions: Our study highlights the effectiveness of short, targeted training in enhancing the diagnostic utility of LC-OCT, emphasising its potential for broader clinical adoption to improve BCC detection.

27 January 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GRGiovanni Rubegni
Giovanni Rubegni
TPTommaso Padula
Tommaso Padula
LCLaura Calabrese
Laura Calabrese
MDMartina D'Onghia
Martina D'Onghia
Linda TognettiLinda Tognetti
Linda Tognetti
Gian TosiGian Tosi
Gian Tosi
Background/Objectives: Eyelid dermatitis is an inflammatory disease affecting the palpebral skin characterized by itching, edema, and scaling of the periorbital area. This entity can be a manifestation of various underlying dermatological diseases, but allergic contact dermatitis (ACD) is the predominant etiology of eyelid dermatitis among patients, being diagnosed in 43.4% of cases. The thin and highly permeable nature of eyelid skin increases its susceptibility to allergens, making it a distinct clinical entity. This study aimed to identify the primary haptens associated with eyelid ACD and compare these findings with the allergens implicated in non-eyelid ACD over a 25-year period in a large cohort of patients. Methods: We conducted a monocentric, retrospective study on a dataset of 7955 patients patch-tested for ACD at the Outpatient Allergy Dermatology Clinic of the Azienda Ospedaliera Universitaria Senese (AOUS) from 1997 to 2021. Eyelid ACD cases were identified based on clinical features and positive patch test results. Data on demographics, occupation, and personal history of atopy were collected. The statistical analyses assessed the associations between allergens and eyelid ACD. The trends in the sensitization rates for the most prevalent allergens were also evaluated. Results: Eyelid ACD was identified in 4.6% of the study population, predominantly affecting women (88.6%). Patients with eyelid ACD were more likely to exhibit single-hapten positivity (54.6%) and an atopic phenotype (52.3%) compared to non-eyelid ACD cases. Nickel sulfate (54%), cobalt chloride (13.4%), and thimerosal (12.6%) were the most common allergens associated with eyelid ACD. While thimerosal sensitization decreased significantly following its removal from topical products, nickel sensitization increased, likely due to exposure from electronic devices and hand–eye contact. Conclusions: The haptens identified in eyelid ACD largely overlap with those found in other body regions, including metals, fragrances, and preservatives. However, the unique characteristics of eyelid skin and hand–eye contact patterns play a significant role in sensitization. This study highlights the need for further investigation into the pathophysiology of eyelid allergic contact dermatitis, with particular emphasis on elucidating the mechanisms of hapten sensitization. Such insights could contribute to the development of effective strategies aimed at reducing allergen exposure.