Stephan Brons

Dr. Stephan Brons

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2017 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CKCarmen Klein
Carmen Klein
IDIvana Dokic
Ivana Dokic
AMAndrea Mairani
Andrea Mairani
SMStewart Mein
Stewart Mein
SBStephan Brons
Stephan Brons
AAAmir Abdollahi
Amir Abdollahi
Hypoxia-induced radioresistance constitutes a major obstacle for a curative treatment of cancer. The aim of this study was to investigate effects of photon and carbon ion irradiation in combination with inhibitors of DNA-Damage Response (DDR) on tumor cell radiosensitivity under hypoxic conditions. Human non-small cell lung cancer (NSCLC) models, A549 and H1437, were irradiated with dose series of photon and carbon ions under hypoxia (1% O2) vs. normoxic conditions (21% O2). Clonogenic survival was studied after dual combinations of radiotherapy with inhibitors of DNA-dependent Protein Kinase (DNAPKi, M3814) and ATM serine/threonine kinase (ATMi). The OER at 30% survival for photon irradiation of A549 cells was 1.4. The maximal oxygen effect measured as survival ratio was 2.34 at 8 Gy photon irradiation of A549 cells. In contrast, no significant oxygen effect was found after carbon ion irradiation. Accordingly, the relative effect of 6 Gy carbon ions was determined as 3.8 under normoxia and. 4.11 under hypoxia. ATM and DNA-PK inhibitors dose dependently sensitized tumor cells for both radiation qualities. For 100 nM DNAPKi the survival ratio at 4 Gy more than doubled from 1.59 under normoxia to 3.3 under hypoxia revealing a strong radiosensitizing effect under hypoxic conditions. In contrast, this ratio only moderately increased after photon irradiation and ATMi under hypoxia. The most effective treatment was combined carbon ion irradiation and DNA damage repair inhibition. Carbon ions efficiently eradicate hypoxic tumor cells. Both, ATMi and DNAPKi elicit radiosensitizing effects. DNAPKi preferentially sensitizes hypoxic cells to radiotherapy.

24 January 2019 in JCI Insight
Verified
Journal Article
Open access
PDF file
SCSara Chiblak
Sara Chiblak
ZTZili Tang
Zili Tang
DLDieter Lemke
Dieter Lemke
MKMaximilian Knoll
Maximilian Knoll
IDIvana Dokic
Ivana Dokic
AAAmir Abdollahi
Amir Abdollahi
Tumor radioresistance leading to local therapy failure remains a major obstacle for successful treatment of high-grade glioma. We hypothesized that distinct radiobiological features of particle therapy with carbon ions may circumvent glioma radioresistance. We demonstrate that carbon irradiation (CIR) efficiently eradicates radioresistant patient-derived glioma stem cells (GSCs), leading to growth inhibition and prolonged survival. The impact of CIR at the tumor–stroma interface was further investigated in 2 syngeneic mouse and 2 orthotopic GSC xenograft models. Intriguingly, tumor regressions and long-term local controls were observed at doses greater than or equal to 15-Gy CIR. Fractionated CIR further prolonged survival. The enhanced relative biological effectiveness of CIR in vivo was attributed to its potent antiangiogenic effects and eradication of radioresistant hypoxic tumor cells. Blockade of the HIF1-α/stromal cell–derived factor 1/CXCR4 axis by CIR reduced the recruitment of microglia and myeloid-derived suppressor cells (CD11b + Gr1 + ). Consequently, CIR abrogated M2-like immune polarization and enhanced the influx of CD8 + cells, generating an immunopermissive niche. We report that radiotherapy with carbon ions could surmount several central glioma resistance mechanisms by eradicating hypoxic and stem cell–like tumor cells, as well as modulating the glioma niche toward an antiangiogenic and less immunosuppressive state. Conclusively, potentially novel rationales for CIR in conquering glioma radioresistance are provided.

13 March 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
DHDaniel Habermehl
Daniel Habermehl
JDJürgen Debus
Jürgen Debus
TGTom Ganten
Tom Ganten
MGMaria-Katharina Ganten
Maria-Katharina Ganten
JBJulia Bauer
Julia Bauer
SCStephanie Combs
Stephanie Combs
Photon-based radiation therapy does currently not play a major role as local ablative treatment for hepatocellular carcinoma (HCC). Carbon ions offer distinct physical and biological advantages. Due to their inverted dose profile and the high local dose deposition within the Bragg peak, precise dose application and sparing of normal tissue is possible. Furthermore, carbon ions have an increased relative biological effectiveness (RBE) compared to photons. A total of six patients with one or more HCC-lesions were treated with carbon ions delivered by the raster-scanning technique according to our clinical trial protocol. Diagnosis of HCC was confirmed by histology or two different imaging modalities (CT and MRI) according to the AASLD-guidelines. Applied fractionation scheme was 4 × 10 Gy(RBE). Correct dose application was controlled by in-vivo PET measurement of β + -activity in the irradiated tissue shortly after treatment. Patients were observed for a median time period of 11.0 months (range, 3.4 - 12.7 months). Imaging studies showed a partial response in 4/7 lesions and a stable disease in 3/7 lesions in follow-up CT- and MRI scans. Local control was 100%. One patient with multifocal intrahepatic disease underwent liver transplantation 3 months after carbon ion therapy. During radiotherapy and the follow-up period no severe adverse events have occurred. We report the first clinical results of patients with HCC undergoing carbon ion therapy using the rasterscanning technique at our institution. All patients are locally controlled and experienced no higher toxicities in a short follow-up period. Further patients will be included in our prospective Phase-I clinical trial PROMETHEUS-01 (NCT01167374).

6 November 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
FSFabian Schlaich
Fabian Schlaich
SBStephan Brons
Stephan Brons
THThomas Haberer
Thomas Haberer
JDJürgen Debus
Jürgen Debus
SCStephanie Combs
Stephanie Combs
KWKlaus Josef Weber
Klaus Josef Weber
Background: Characterization of combination effects of chemotherapy drugs with carbon ions in comparison to photons in vitro. Methods: The human colon adenocarcinoma cell line WiDr was tested for combinations with camptothecin, cisplatin, gemcitabine and paclitaxel. In addition three other human tumour cell lines (A549: lung, LN-229: glioblastoma, PANC-1: pancreas) were tested for the combination with camptothecin. Cells were irradiated with photon doses of 2, 4, 6 and 8 Gy or carbon ion doses of 0.5, 1, 2 and 3 Gy. Cell survival was assessed using the clonogenic growth assay. Treatment dependent changes in cell cycle distribution (up to 12 hours post-treatment) were measured by FACS analysis after propidium-iodide staining. Apoptosis was monitored for up to 36 hours post-treatment by Nicoletti-assay (with qualitative verification using DAPI staining). Results: All cell lines exhibited the well-known increase of killing efficacy per unit dose of carbon ion exposure, with relative biological efficiencies at 10% survival (RBE10) ranging from 2.3 to 3.7 for the different cell lines. In combination with chemotherapy additive toxicity was the prevailing effect. Only in combination with gemcitabine or cisplatin (WiDr) or camptothecin (all cell lines) the photon sensitivity was slightly enhanced, whereas purely independent toxicities were found with the carbon ion irradiation, in all cases. Radiation-induced cell cycle changes displayed the generally observed dose-dependent G2-arrest with little effect on S-phase fraction for all cell lines for photons and for carbon ions. Only paclitaxel showed a significant induction of apoptosis in WiDr cell line but independent of the used radiation quality. Conclusions: Combined effects of different chemotherapeutics with photons or with carbon ions do neither display qualitative nor substantial quantitative differences. Small radiosensitizing effects, when observed with photons are decreased with carbon ions. The data support the idea that a radiochemotherapy with common drugs and carbon ion irradiation might be as feasible as respective photon-based protocols. The present data serve as an important radiobiological basis for further combination experiments, as well as clinical studies on combination treatments.

28 February 2020 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
LVLennart Volz
Lennart Volz
LKLaurent Kelleter
Laurent Kelleter
SBStephan Brons
Stephan Brons
LBLucas N Burigo
Lucas N Burigo
CGChristian Graeff
Christian Graeff
Joao SecoJoao Seco
Joao Seco
Recently, it has been proposed that a mixed helium/carbon beam could be used for online monitoring in carbon ion beam therapy. Fully stripped, the two ion species exhibit approximately the same mass/charge ratio and hence could potentially be accelerated simultaneously in a synchrotron to the same energy per nucleon. At the same energy per nucleon, helium ions have about three times the range of carbon ions, which could allow for simultaneous use of the carbon ion beam for treatment and the helium ion beam for imaging. In this work, measurements and simulations of PMMA phantoms as well as anthropomorphic phantoms irradiated sequentially with a helium ion and a carbon ion beam at equal energy per nucleon are presented. The range of the primary helium ion beam and the fragment tail of the carbon ion beam exiting the phantoms were detected using a novel range telescope made of thin plastic scintillator sheets read out by a flat-panel CMOS sensor. A 10:1 carbon to helium mixing ratio is used, generating a helium signal well above the carbon fragment background while adding little to the dose delivered to the patient. The range modulation of a narrow air gap of 1 mm thickness in the PMMA phantom that affects less than a quarter of the particles in a pencil beam were detected, demonstrating the achievable relative sensitivity of the presented method. Using two anthropomorphic pelvis phantoms it is shown that small rotations of the phantom as well as simulated bowel gas movements cause detectable changes in the helium/carbon beam exiting the phantom. The future prospects and limitations of the helium/carbon mixing as well as its technical feasibility are discussed.

21 November 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CDConstantin Dreher
Constantin Dreher
DHDaniel Habermehl
Daniel Habermehl
SESwantje Ecker
Swantje Ecker
SBStephan Brons
Stephan Brons
RSRami Ateyah El Shafie
Rami Ateyah El Shafie
SCStephanie Combs
Stephanie Combs
The aim of the thesis is to improve radiation plans of patients with locally advanced, unresectable pancreatic cancer by using carbon ion and proton beams. Using the treatment planning system Syngo RT Planning (Siemens, Erlangen, Germany) a total of 50 treatment plans have been created for five patients with the dose schedule 15 × 3 Gy(RBE). With reference to the anatomy, five field configurations were considered to be relevant. The plans were analyzed with respect to dose distribution and individual anatomy, and compared using a customized index. Within the index the three-field configurations yielded the best results, though with a high variety of score points (field setup 5, carbon ion: median 74 (range 48–101)). The maximum dose in the myelon is low (e.g. case 3, carbon ion: 21.5 Gy(RBE)). A single posterior field generally spares the organs at risk, but the maximum dose in the myelon is high (e.g. case 3, carbon ion: 32.9 Gy(RBE)). Two oblique posterior fields resulted in acceptable maximum doses in the myelon (e.g. case 3, carbon ion: 26.9 Gy(RBE)). The single-field configuration and the two oblique posterior fields had a small score dispersion (carbon ion: median 66 and 58 (range 62–72 and 40–69)). In cases with topographic proximity of the organs at risk to the target volume, the single-field configuration scored as well as the three-field configurations. In summary, the three-field configurations showed the best dose distributions. A single posterior field seems to be robust and beneficial in case of difficult topographical conditions and topographical proximity of organs at risk to the target volume. A setup with two oblique posterior fields is a reasonable compromise between three-field and single-field configurations.