Purpose Since the introduction of positron emission tomography (PET) imaging with 68Ga-PSMA-HBED-CC (=68Ga-DKFZ-PSMA-11), this method has been regarded as a significant step forward in the diagnosis of recurrent prostate cancer (PCa). However, published data exist for small patient cohorts only. The aim of this evaluation was to analyse the diagnostic value of 68Ga-PSMA-ligand PET/CT in a large cohort and the influence of several possibly interacting variables. Methods We performed a retrospective analysis in 319 patients who underwent 68Ga-PSMA-ligand PET/CT from 2011 to 2014. Potential influences of several factors such as prostate-specific antigen (PSA) level and doubling time (DT), Gleason score (GSC), androgen deprivation therapy (ADT), age and amount of injected tracer were evaluated. Histological verification was performed in 42 patients after the 68Ga-PSMA-ligand PET/CT. Tracer uptake was measured in 901 representative tumour lesions. Results In 82.8 % of the patients at least one lesion indicative of PCa was detected. Tumor-detection was positively associated with PSA level and ADT. GSC and PSA-DT were not associated with tumor-detection. The average maximum standardized uptake value (SUVmax) of tumour lesions was 13.3 ± 14.6 (0.7–122.5). Amongst lesions investigated by histology, 30 were false-negative in 4 different patients, and all other lesions (n = 416) were true-positive or true-negative. A lesion-based analysis of sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) revealed values of 76.6 %, 100 %, 91.4 % and 100 %. A patient-based analysis revealed a sensitivity of 88.1 %. Of 116 patients available for follow-up, 50 received local therapy after 68Ga-PSMA-ligand PET/CT. Conclusion 68Ga-PSMA-ligand PET/CT can detect recurrent PCa in a high number of patients. In addition, the radiotracer is highly specific for PCa. Tumour detection is positively associated with PSA and ADT. 68Ga-PSMA-ligand PET/CT can help delay systemic therapy of PCa.
27 September 2013 in European Journal of Nuclear Medicine and Molecular Imaging
Purpose Positron emission tomography (PET) with choline tracers has found widespread use for the diagnosis of prostate cancer (PC). However, choline metabolism is not increased in a considerable number of cases, whereas prostate-specific membrane antigen (PSMA) is overexpressed in most PCs. Therefore, a 68Ga-labelled PSMA ligand could be superior to choline tracers by obtaining a high contrast. The aim of this study was to compare such a novel tracer with standard choline-based PET/CT. Methods Thirty-seven patients with biochemical relapse of PC [mean prostate-specific antigen (PSA) 11.1 ± 24.1 ng/ml, range 0.01–116] were retrospectively analysed after 18F-fluoromethylcholine and 68Ga-PSMA PET/CT within a time window of 30 days. Radiotracer uptake that was visually considered as PC was semi-quantitatively analysed by measuring the maximum standardized uptake values (SUVmax) of the scans acquired 1 h after injection of 68Ga-PSMA complex solution (median 132 MBq, range 59–263 MBq) and 18F-fluoromethylcholine (median 237 MBq, range 114–374 MBq), respectively. In addition, tumour to background ratios were calculated. Results A total of 78 lesions characteristic for PC were detected in 32 patients using 68Ga-PSMA PET/CT and 56 lesions were detected in 26 patients using choline PET/CT. The higher detection rate in 68Ga-PSMA PET/CT was statistically significant (p = 0.04). In five patients no lesion was found with both methods. All lesions detected by 18F-fluoromethylcholine PET/CT were also seen by 68Ga-PSMA PET/CT. In 68Ga-PSMA PET/CT SUVmax was clearly (>10 %) higher in 62 of 78 lesions (79.1 %) and the tumour to background ratio was clearly (>10 %) higher in 74 of 78 lesions (94.9 %) when compared to 18F-fluoromethylcholine PET/CT. Conclusion 68Ga-PSMA PET/CT can detect lesions characteristic for PC with improved contrast when compared to standard 18F-fluoromethylcholine PET/CT, especially at low PSA levels.
15 October 2020 in BMC Medical Research Methodology
Background: Projection of future cancer incidence is an important task in cancer epidemiology. The results are of interest also for biomedical research and public health policy. Age-Period-Cohort (APC) models, usually based on long-term cancer registry data (> 20 yrs), are established for such projections. In many countries (including Germany), however, nationwide long-term data are not yet available. General guidance on statistical approaches for projections using rather short-term data is challenging and software to enable researchers to easily compare approaches is lacking. Methods: To enable a comparative analysis of the performance of statistical approaches to cancer incidence projection, we developed an R package (incAnalysis), supporting in particular Bayesian models fitted by Integrated Nested Laplace Approximations (INLA). Its use is demonstrated by an extensive empirical evaluation of operating characteristics (bias, coverage and precision) of potentially applicable models differing by complexity. Observed long-term data from three cancer registries (SEER-9, NORDCAN, Saarland) was used for benchmarking. Results: Overall, coverage was high (mostly > 90%) for Bayesian APC models (BAPC), whereas less complex models showed differences in coverage dependent on projection-period. Intercept-only models yielded values below 20% for coverage. Bias increased and precision decreased for longer projection periods (> 15 years) for all except intercept-only models. Precision was lowest for complex models such as BAPC models, generalized additive models with multivariate smoothers and generalized linear models with age x period interaction effects. Conclusion: The incAnalysis R package allows a straightforward comparison of cancer incidence rate projection approaches. Further detailed and targeted investigations into model performance in addition to the presented empirical results are recommended to derive guidance on appropriate statistical projection methods in a given setting.
Magnetic Resonance-guided radiotherapy (MRgRT) marks the beginning of a new era. MR is a versatile and suitable imaging modality for radiotherapy, as it enables direct visualization of the tumor and the surrounding organs at risk. Moreover, MRgRT provides real-time imaging to characterize and eventually track anatomical motion. Nevertheless, the successful translation of new technologies into clinical practice remains challenging. To date, the initial availability of next-generation hybrid MR-linac (MRL) systems is still limited and therefore, the focus of the present preview was on the initial applicability in current clinical practice and on future perspectives of this new technology for different treatment sites. MRgRT can be considered a groundbreaking new technology that is capable of creating new perspectives towards an individualized, patient-oriented planning and treatment approach, especially due to the ability to use daily online adaptation strategies. Furthermore, MRL systems overcome the limitations of conventional image-guided radiotherapy, especially in soft tissue, where target and organs at risk need accurate definition. Nevertheless, some concerns remain regarding the additional time needed to re-optimize dose distributions online, the reliability of the gating and tracking procedures and the interpretation of functional MR imaging markers and their potential changes during the course of treatment. Due to its continuous technological improvement and rapid clinical large-scale application in several anatomical settings, further studies may confirm the potential disruptive role of MRgRT in the evolving oncological environment.
To report the primary endpoint of a randomized trial comparing pain response following palliative stereotactic body radiation therapy (SBRT) versus conventionally-fractionated 3D-conformal radiotherapy (3DCRT) for previously untreated spinal metastases. Fifty-five patients with histologically/radiologically confirmed painful spinal metastases were analyzed in this single-institutional, non-blinded, randomized explorative trial. Participants were randomly assigned (1:1) to receive single-fraction SBRT (24 Gy) or 3DCRT (30 Gy in 10 fractions). The primary endpoint was pain relief of >2 points on the visual analog scale (VAS) measured within the irradiated region at 3 months following radiotherapy completion. Other recorded parameters included pain response (per International Bone Consensus response definitions), use of concurrent medications and opioid usage (oral morphine equivalent dose, OMED). All parameters were assessed at baseline and at three and six months after RT. Intention-to-treat analysis was applied. This trial is registered with ClinicalTrials.gov, number NCT02358720. Despite no significant differences for VAS at 3 months between groups (p = 0.13), pain values decreased faster within this time period in the SBRT arm (p = 0.01). At 6 months following RT, significantly lower VAS values were reported in the SBRT group (p = 0.002). There were no differences in OMED consumption at 3 (p = 0.761) and 6 months (p = 0.174). There was a trend toward improved pain response in the SBRT arm at 3 months (p = 0.057), but significantly so after 6 months (p = 0.003). No patient in the SBRT group experienced grade ≥3 toxicities according to the Common Terminology Criteria for Adverse Events v.4.03. This randomized trial demonstrates the utility of palliative SBRT for spinal metastases, which was associated with a quicker and improved pain response. Larger ongoing randomized studies will assist in further addressing these endpoints.
Patients with Echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) positive lung cancer are sensitive to ALK-kinase inhibitors. TAE684 is a potent second generation ALK inhibitor that overcomes Crizotinib resistance. Radiotherapy is an integral therapeutic component of locally advanced lung cancer. Therefore, we sought to investigate the effects of combined radiotherapy and ALK-inhibition via TAE684 in ALK-positive vs. wild type lung cancer cells. Human non-small cell lung cancer (NSCLC) cell lines harboring wild-type ALK (A549), EML4-ALK translocation (H3122) and murine Lewis Lung Cancer (LLC) cells were investigated. Cells were irradiated with 1–4 Gy X-Rays (320 keV) and carbon ions (Spread-out Bragg Peak, SOBP (245.4–257.0 MeV/u)) at Heidelberg Ion Therapy center. TAE684 was administered at the dose range 0–100 nM. Clonogenic survival, proliferation and apoptosis via caspase 3/7 expression level were assessed in all three cell lines using time-lapse live microscopy. TAE684 inhibited the proliferation of H3122 cells in a dose-dependent manner with a half maximal inhibitory concentration (IC50) of ~ 8.2 nM. However, A549 and LLC cells were relatively resistant to TAE684 and IC50 was not reached at concentrations tested (up to 100 nM) in proliferation assay. The antiproliferative effect of TAE684 was augmented by radiotherapy in H3122 cells. TAE684 significantly sensitized H3122 cells to particle therapy with carbon ions (sensitizer enhancement ratio ~1.61, p < 0.05). Caspase 3/7 activity was evidently enhanced after combination therapy in H3122 cells. This is the first report demonstrating synergistic effects of combined TAE684 and radiotherapy in EML4-ALK positive lung cancer cells. In addition to conventional photon radiotherapy, ALK-inhibition also enhanced the effects of particle irradiation using carbon ions. Our data indicate beneficial effects of combined ALK-inhibition and radiotherapy in treatment of this distinct subpopulation of NSCLC that warrant further evaluation.