Andreas Liebold

Prof. Dr. Andreas Liebold

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Journal of Pain Research
Verified
Journal Article
Open access
PDF file
MZMarek Zubrzycki
Marek Zubrzycki
ALAndreas Liebold
Andreas Liebold
CSChristian Skrabal
Christian Skrabal
HRHelmut Reinelt
Helmut Reinelt
MZMechthild Ziegler
Mechthild Ziegler
MZMaria Zubrzycka
Maria Zubrzycka
Analysis of the problem of surgical pain is important in view of the fact that the success of surgical treatment depends largely on proper pain management during the first few days after a cardiosurgical procedure. Postoperative pain is due to intraoperative damage to tissue. It is acute pain of high intensity proportional to the type of procedure. The pain is most intense during the first 24 hours following the surgery and decreases on subsequent days. Its intensity is higher in younger subjects than elderly and obese patients, and preoperative anxiety is also a factor that increases postoperative pain. Ineffective postoperative analgesic therapy may cause several complications that are dangerous to a patient. Inappropriate postoperative pain management may result in chronic pain, immunosuppression, infections, and less effective wound healing. Understanding and better knowledge of physiological disorders and adverse effects resulting from surgical trauma, anesthesia, and extracorporeal circulation, as well as the development of standards for intensive postoperative care units are critical to the improvement of early treatment outcomes and patient comfort.

17 December 2011 in Clinical Research in Cardiology
Verified
Journal Article
Open access
PDF file
IAIbrahim Akin
Ibrahim Akin
SKS. Kische
S. Kische
HSH. Schneider
H. Schneider
ALAndreas Liebold
Andreas Liebold
JOJ. Ortak
J. Ortak
HIH. Ince
H. Ince
Background Transcatheter aortic valve implantation (TAVI) has been developed to minimize operative morbidity and mortality in high-risk symptomatic patients unfit for open surgery. With the proximity of the aortic valve annulus to the conduction system there is, however, an unknown risk of conduction disturbances necessitating monitoring and often cardiac pacing. Materials and methods We enrolled 50 consecutive patients from January 2007 to 2008 in our prospective evaluation of conduction disturbances measured by surface and intracardiac ECG recordings. Baseline parameters, procedural characteristics as well as twelve-lead surface ECG and intracardiac conduction times were revealed pre-interventionally, after TAVI and at 7-day follow-up. Results TAVI was performed successfully in all patients. During 7 days of follow-up the rate for first-degree AV block raised from 14% at baseline to 44% at day 7 (p < 0.001), while rates for type II second- and third-degree were 0 versus 8% (p < 0.001) and 0 versus 12% (p < 0.001), respectively. Similarly, the prevalence of new left bundle branch block (LBBB) rose from 2 to 54% (p < 0.001). Intracardiac measurements revealed a prolongation of both AH and HV interval from 123.7 ± 41.6 to 136.6 ± 40.5 ms (p < 0.001) and from 54.8 ± 11.7 to 71.4 ± 20.0 ms (p < 0.001), respectively. Pacemaker implantation at a mean follow-up of 4.8 ± 1.2 days was subsequently performed in 23 patients (46%) due to complete AV block (12%) and type II second-degree AV block (8%) while another 13 patients (26%) received a pacemaker for the combination of new LBBB with marked HV prolongation. The high rate of first-degree AV block was primarily driven by an increase in HV interval. Conclusion Cardiac conduction disturbances were common in the early experience with CoreValve implantation necessitating close surveillance for at least 1 week.

1 March 2007 in Respiratory Physiology & Neurobiology
Verified
Journal Article
Closed access
AKA. Kaminski
A. Kaminski
CKC. Kasch
C. Kasch
LZL. Zhang
L. Zhang
SKS. Kumar
S. Kumar
CSChristoph Sponholz
Christoph Sponholz
Christof StammChristof Stamm
Christof Stamm

1 June 2019 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
ALAndreas Liebold
Andreas Liebold
GAGünter Albrecht
Günter Albrecht
Minimally invasive extracorporeal circulation (MiECC) technology is characterized by improved biocompatibility due to closed-loop design, minimized priming, and markedly reduced artificial surface. Despite well-evidenced clinical advantages in coronary surgery, MiECC penetration in complex open-heart surgery is low. Concerns have been raised by surgeons and perfusionist regarding safety of perfusion in situations when the heart is opened and air is entering the closed system. Moreover, issues of blood and volume management are deemed impractical without having a reservoir. In the evolution of MiECC safety aspects as well as means of air and volume management have been addressed. The integration of active air removal devices, and the possibility of venting and volume buffering made MiECC suitable for valvular or even more complex surgery. However, typical clinical benefits found with MiECC in coronary artery bypass grafting (CABG) surgery, in particular blood sparing effects, were not reproducible. Air handling and blood management remain the main issues of MiECC in non-coronary surgery. With the introduction of modular (type IV) MiECC systems containing a second, accessory circuit for immediate conversion to open cardiopulmonary bypass (CPB), the last obstacles seem to be cleared away. The first reports using this latest development in MiECC technology sound promising. It is now up to the cardiac surgical community to adopt this technology and produce data helping to answer the question whether MiECC is the best perfusion strategy for all comer’s cardiac surgery.

8 March 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PTPatrick Thiam
Patrick Thiam
Christopher KlothChristopher Kloth
Christopher Kloth
DBDaniel Blaich
Daniel Blaich
ALAndreas Liebold
Andreas Liebold
Meinrad BeerMeinrad Beer
Meinrad Beer
HKHans Kestler
Hans Kestler
The successful integration of neural networks in a clinical setting is still uncommon despite major successes achieved by artificial intelligence in other domains. This is mainly due to the black box characteristic of most optimized models and the undetermined generalization ability of the trained architectures. The current work tackles both issues in the radiology domain by focusing on developing an effective and interpretable cardiomegaly detection architecture based on segmentation models. The architecture consists of two distinct neural networks performing the segmentation of both cardiac and thoracic areas of a radiograph. The respective segmentation outputs are subsequently used to estimate the cardiothoracic ratio, and the corresponding radiograph is classified as a case of cardiomegaly based on a given threshold. Due to the scarcity of pixel-level labeled chest radiographs, both segmentation models are optimized in a semi-supervised manner. This results in a significant reduction in the costs of manual annotation. The resulting segmentation outputs significantly improve the interpretability of the architecture’s final classification results. The generalization ability of the architecture is assessed in a cross-domain setting. The assessment shows the effectiveness of the semi-supervised optimization of the segmentation models and the robustness of the ensuing classification architecture.

25 March 2021 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
FBFarhad Bakhtiary
Farhad Bakhtiary
AAAli El-Sayed Ahmad
Ali El-Sayed Ahmad
RARüdiger Autschbach
Rüdiger Autschbach
PBPeter Univ.-Prof. Dr. Andreas F. Benedikt
Peter Univ.-Prof. Dr. Andreas F. Benedikt
Nikolaos BonarosNikolaos Bonaros
Nikolaos Bonaros
AZAndreas F. Zierer
Andreas F. Zierer
Background: Degenerative aortic valve disease accounts for 10–20% of all cardiac surgical procedures. The impact of pre-existing comorbidities on the outcome of patients undergoing surgical aortic valve replacement (SAVR) needs further research. Methods: The IMPACT registry is a non-interventional, prospective, open-label, multicenter, international registry with a follow-up of 5 years to assess the impact of pre-existing comorbidities of patients undergoing SAVR with the INSPIRIS RESILIA aortic valve on outcomes. IMPACT will be conducted across 25 sites in Austria, Germany, The Netherlands and Switzerland and intends to enroll approximately 500 patients. Patients will be included if they are at least 18 years of age and are scheduled to undergo SAVR with the INSPIRIS RESILIA Aortic Valve with or without concomitant ascending aortic root replacement and/or coronary bypass surgery. The primary objective is to determine all-cause mortality at 1, 3, and 5 years post SAVR. Secondary objectives include cardiac-related and valve-related mortality and structural valve deterioration including hemodynamics and durability, valve performance and further clinical outcomes in the overall study population and in specific patient subgroups characterized by the presence of chronic kidney disease, hypertension, metabolic syndrome and/or chronic inflammation. Discussion: IMPACT is a prospective, multicenter European registry, which will provide much-needed data on the impact of pre-existing comorbidities on patient outcomes and prosthetic valve performance, and in particular the performance of the INSPIRIS RESILIA, in a real-world setting. The findings of this study may help to support and expand appropriate patient selection for treatment with bioprostheses. Trial registration: ClinicalTrials.gov identifier: NCT04053088.