17 December 2011 in Clinical Research in Cardiology
Background Transcatheter aortic valve implantation (TAVI) has been developed to minimize operative morbidity and mortality in high-risk symptomatic patients unfit for open surgery. With the proximity of the aortic valve annulus to the conduction system there is, however, an unknown risk of conduction disturbances necessitating monitoring and often cardiac pacing. Materials and methods We enrolled 50 consecutive patients from January 2007 to 2008 in our prospective evaluation of conduction disturbances measured by surface and intracardiac ECG recordings. Baseline parameters, procedural characteristics as well as twelve-lead surface ECG and intracardiac conduction times were revealed pre-interventionally, after TAVI and at 7-day follow-up. Results TAVI was performed successfully in all patients. During 7 days of follow-up the rate for first-degree AV block raised from 14% at baseline to 44% at day 7 (p < 0.001), while rates for type II second- and third-degree were 0 versus 8% (p < 0.001) and 0 versus 12% (p < 0.001), respectively. Similarly, the prevalence of new left bundle branch block (LBBB) rose from 2 to 54% (p < 0.001). Intracardiac measurements revealed a prolongation of both AH and HV interval from 123.7 ± 41.6 to 136.6 ± 40.5 ms (p < 0.001) and from 54.8 ± 11.7 to 71.4 ± 20.0 ms (p < 0.001), respectively. Pacemaker implantation at a mean follow-up of 4.8 ± 1.2 days was subsequently performed in 23 patients (46%) due to complete AV block (12%) and type II second-degree AV block (8%) while another 13 patients (26%) received a pacemaker for the combination of new LBBB with marked HV prolongation. The high rate of first-degree AV block was primarily driven by an increase in HV interval. Conclusion Cardiac conduction disturbances were common in the early experience with CoreValve implantation necessitating close surveillance for at least 1 week.
8 December 2014 in IEEE Transactions on Power Electronics
This paper presents an efficiency optimization approach for a high-voltage bidirectional flyback dc-dc converter. The main goal is to optimize the converter for driving a capacitive actuator, which must be charged and discharged from 0 V to 2.5 kV dc and vice versa, supplied from a 24 V dc supply. The energy efficiency is optimized using a proposed new automatic winding layout (AWL) technique and a comprehensive loss model. The AWL technique generates a large number of transformer winding layouts. The transformer parasitics, such as dc resistance, leakage inductance, and self-capacitance are calculated for each winding layout. An optimization technique is formulated to minimize the sum of energy losses during charge and discharge operations. The efficiency and energy loss distribution results from the optimization routine provide a deep insight into the high-voltage transformer design and its impact on the total converter efficiency. The proposed efficiency optimization approach is experimentally verified on a 25 W (average charging power) with a 100 W (peak power) flyback dc-dc prototype.
29 December 2010 in Stem Cell Reviews and Reports
Objectives There is growing evidence that intracoronary autologous bone marrow cells transplantation (BMCs-Tx) in patients with chronic myocardial infarction beneficially affects postinfarction remodelling. In this randomized controlled study we analyzed the influence of intracoronary autologous freshly isolated bone marrow cells transplantation by use of point of care system on cardiac function and on the functional activity of bone marrow derived circulating progenitor cells (BM-CPCs) in patients with ischemic heart disease (IHD). Methods 56 patients with IHD were randomized to either received freshly isolated BMC-Tx or a control group that did not receive cell therapy. The functional activity of BM-CPCs in peripheral blood (PB) was measured by migration assay and colony forming unit assay pre- and 3, 6 as well as 12 months after procedure. Global ejection fraction (EF) and infarct size area were determined by left ventriculography. Results Intracoronary transplantation of autologous freshly isolated BMCs led to a significant reduction of infarct size and an increase of global EF as well as infarct wall movement velocity after 3 and 12 months follow-up compared to control group. The colony-forming capacity of BM-CPCs significantly increased 3, 6 and 12 months after cell therapy compared to pre BMCs-Tx and control group (CFU-E: p < 0.001, CFU-GM: p < 0.001). Likewise, we found significant increase of migratory response to stromal cell-derived factor 1 (SDF-1) and vascular endothelial growth factor (VEGF) after cell therapy compared to pre BMCs-Tx (SDF-1: p < 0.001, VEGF: p < 0.001) and to control (SDF-1: p < 0.001, VEGF: p < 0.001). There was no significant difference of migratory- and colony forming capacity between pre- and 3, 6, 12 months after coronary angiography in control group without cell therapy. Conclusions Intracoronary transplantation of autologous freshly isolated BMCs by use of point of care system may lead to improvement of BM-CPCs functional activity in peripheral blood, which might increase the regenerative potency in patients with IHD.
1 January 2002 in Acta Chirurgica Belgica
The acute aortic syndrome (AAS) is described. Its pathophysiology is discussed for each of the three entities (penetrating aortic ulcer, intramural hematoma and aortic dissection). The natural history of these three pathologies is reviewed. Diagnostic features and investigation imaging techniques are summerized. The technique of stentgraft-placement is described in detail. The authors report their clinical experience with 127 patients, presenting acute type B aortic dissection or its variants, and treated with an endovascular stent-graft-device. These results are in part compared with a group of control patients with acute type B dissection, submitted to medical non-invasive therapy.