Ambran Hartono

Dr. Ambran Hartono

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
AHAmbran Hartono
Ambran Hartono
ESEdi Sanjaya
Edi Sanjaya
Ramli RamliRamli Ramli
Ramli Ramli
A polyvinylidene fluoride (PVDF) film-based capacitive biosensor was developed for glucose sensing. This device consists of a PVDF film sandwiched between two electrodes. A capacitive biosensor measures the dielectric properties of the dielectric layers at the interface between the electrolyte and the electrode. A glucose oxidase (GOx) enzyme was immobilized onto the electrode to oxidize glucose. In practice, the biochemical reaction of glucose with the GOx enzyme generates free electron carriers. Consequently, the potential difference between the electrodes is increased, resulting in a measurable voltage output of the biosensor. The device was tested for various glucose concentrations in the range of 0.013 to 5.85 M, and various GOx enzyme concentrations between 4882.8 and 2.5 million units/L. We found that the sensor output increased with increasing glucose concentration up to 5.85 M. These results indicate that the PVDF film-based capacitive biosensors can be properly applied to glucose sensing and provide opportunities for the low-cost fabrication of glucose-based biosensors based on PVDF materials.

5 April 2023 in EKSAKTA: Berkala Ilmiah Bidang MIPA
Verified
Journal Article
Open access
PDF file
AHAmbran Hartono
Ambran Hartono
ARAhmad Rofiq
Ahmad Rofiq
JPJalu Ahmad Prakosa
Jalu Ahmad Prakosa
RRRamli Ramli
Ramli Ramli
SSSyafrijon Syafrijon
Syafrijon Syafrijon
Bio floc aquaculture techniques are present as a solution to increase the productivity of fish farming. However, until now there are still problems, namely regarding the quality of the water from the pond. In this study, a monitoring tool was designed using an ESP32 microcontroller with the support of a BME280 sensor, RTD PT100 to measure water temperature and a turbidity sensor to measure floc volume. Furthermore, this sensor is planted on Wi-Fi to be able to connect to the internet network for IoT applications so that it can be monitored in real time. Likewise, the display results from the monitoring of the application system are directly read on the Google sheet display and in real time. From the test results of the system built, obtained the accuracy level of the BME280 sensor is 96.5%, PT100 RTD is 94.6% and for the turbidity sensor is 98%. Meanwhile the observed air temperature value can reach 34.36°C, the water temperature reaches 28.75°C, and the floc ratio reaches 30.15 mL.L-1. From the results shown, it clearly indicates that the water quality monitoring system has been successful and is working very well.

1 January 2017
Verified
Conference Paper
Open access
PDF file
AMAhmad Novi Muslimin
Ahmad Novi Muslimin
AHAmbran Hartono
Ambran Hartono
ATArif Tjahjono
Arif Tjahjono
NFNurul Fadilah
Nurul Fadilah
PPPriyambodo Priyambodo
Priyambodo Priyambodo
PVDF film is a piezoelectric material that is still being developed as transducer and piezoelectric sensor. It is caused by the piezoelectric constant and the mechanical properties of PVDF are larger than the existing polymer piezoelectric. The high demand for the use of PVDF films makes it possible to make low-cost PVDF films with high piezoelectric properties. There are a variety of techniques used to make PVDF films especially PVDF films that have high β-phase fractions. In this research, PVDF film was made using simple hot press, at temperature 165ᴼC, 180ᴼC and 195ᴼC and heating time 15, 30 and 45 minutes. From the research results, PVDF film produced with the smallest thickness of 200μm and the largest is 345μm. The largest fraction of β obtained was 40.47% at 180 ° C with 30 minutes heat heating time and the smallest fraction of β obtained was 31.05% at a hot press temperature of 165 ᴼC at heating time of 45 minutes. Based on the value of β fraction obtained, at a press temperature of 180 ᴼC and a 30 minute heating time is a good process used for PVDF filmmaking. Keywords: PVDF film, hot press, β fraction, piezoelectric.

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
PUPurwowibowo
Purwowibowo
JPJalu Ahmad Prakosa
Jalu Ahmad Prakosa
Edi KurniawanEdi Kurniawan
Edi Kurniawan
Enggar Banifa PratiwiEnggar Banifa Pratiwi
Enggar Banifa Pratiwi
AHAmbran Hartono
Ambran Hartono
Moisture is an essential aspect of the skin because cracks usually appear when the skin lacks water. A skin moisture meter is intended to determine the moisture Moisture is an essential aspect of the skin because cracks usually appear when the skin lacks water. A skin moisture meter is intended to determine the moisture