Jitendra Kumar Nama

Dr. Jitendra Kumar Nama


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JNJitendra Kumar Nama
Jitendra Kumar Nama
AVArun Kumar Verma
Arun Kumar Verma
MSManaswi Srivastava
Manaswi Srivastava
PAVAN TOMARPAVAN TOMAR
PAVAN TOMAR
Recently available high-frequency power converter topologies for IPT system utilizes either zero voltage switching (ZVS) or zero current switching (ZCS) based power electronic converters while maintaining a near sinusoidal current for limited power transfer range. However, achieving ZVS or ZCS for all power switches simultaneously is still a challenging task in IPT systems. In this paper, an improved zero voltage zero current switching (ZVZCS) IPT topology and its switching pattern are proposed. ZVS is achieved by optimizing the classical series compensation and additionally, an auxiliary network is employed to achieve ZCS. The proposed concept is verified by using MATLAB/ SIMULINK based simulations for resistive and battery load. Finally, the practical viability of the proposed topology is validated by the results obtained using a laboratory prototype rated for 1.1kW, 85 kHz. An efficiency of 91.26% is achieved with ZVZCS for a full dynamic power transfer range of 20W to 1.1kW.

1 November 2016
Verified
Conference Paper
Closed access
NGNiharika Gotherwal
Niharika Gotherwal
JNJitendra Kumar Nama
Jitendra Kumar Nama
SRSoumyadeep Ray
Soumyadeep Ray
NGNitin Gupta
Nitin Gupta
The shunt active filters play a dominant role for eradication of power quality problems in modern era, where the majority of load has non-linear nature. It is very important for an active filter to acquire accurate reference current extraction technique as the inaccuracy leads to incorrect compensation and lost control over the DC link. In this paper, three significantapproachesnamely the instantaneous power theory (IPT), unit vector control (UVT) and synchronous reference frame theory (SRF) for reference current extraction have been assessed, evaluated and compared. Thesecontrol schemes are based on indirect current control technique (ICC) and in all methods PI controller is used for stabilization of the DC-link voltage. The advantages and limitations of reference current extraction methods found in literature have been also discussed and justified on the basis of MATLAB simulations for current source type of load, voltage source type of load and transient load conditions.