Transmission towers constitute critical power infrastructure, yet structural damage may accumulate over their long-term service, underscoring the paramount importance of research on damage identification. This paper presents a cross-correlation function amplitude vector (CorV) method for damage localization based on time-domain response analysis. The approach involves calculating the CorV of structural members before and after damage using dynamic response data, employing the CorV assurance criterion (CVAC) to quantify changes in CorV, and introducing first-order differencing for damage localization. Taking an actual transmission tower in Jiangmen as the engineering backdrop, a finite element model is established. Damage conditions are simulated by reducing the stiffness of specific members, and parameter analyses are conducted to validate the proposed method. Furthermore, experimental validation in a lab is performed to provide additional confirmation. The results indicate that the CVAC value of the damaged structure is significantly lower than that in the healthy state. By analyzing the relative changes in the components of CorV, the damage location can be accurately determined. Notably, this method only requires acquiring the time-domain response signals of the transmission tower under random excitation to detect both the existence and location of damage. Consequently, it is well suited for structural health monitoring of transmission towers under environmental excitation.
Conductor galloping is a serious threat to transmission line integrity, inducing excessive conductor tension that may lead to catastrophic failures including conductor breakage and tower collapse. This study proposes a novel self-adaptive anti-galloping device (SAGD) to mitigate galloping amplitudes and reduce associated risks. In this paper a novel self-adaptive anti-galloping device (SAGD) to mitigate galloping amplitudes and reduce associated risks was proposed. The structural design scheme of the device is provided, and its operation sequence was verified through static loading experiments. Conductor free-falling experiments validated the SAGD's vibration control performance, with test results demonstrating its practical applicability for transmission line protection. A finite element model for the conductor-SAGD system was developed, enabling numerical simulation of galloping displacement time history and analysis of endpoint support reaction dynamics. The device's galloping suppression effectiveness is systematically evaluated under varying stroke lengths and threshold conditions.