Background/Objectives: MMAE (middle meningeal artery embolization) has emerged as a potential effective treatment for cSDH (chronic subdural hematoma). In this study, MMAE efficiency with regards to cSDH cause and architecture was explored. The comparability of cSDH thickness and volume as parameters for cSDH pre- and post-MMAE assessment was also analyzed. Methods: In this retrospective cohort study, 52 consecutive cSDH patients treated with MMAE in a single tertiary center were included. The cohort was divided into two group pairs pertaining to cSDH cause (spontaneous or traumatic) and cSDH architecture (non-mature or mature). The radiological outcome was compared in each group before and after MMAE and between each group pair using CT imaging. A correlation analysis between cSDH thickness and volume before and after MMAE was also performed. Results: A statistically significant positive linear association between cSDH thickness and volume at admission and at each follow-up interval (1–3, 3–6, 6–12 months) was noticed. cSDH thickness and volume reduction in each group was statistically significant, except for a traumatic cSDH volume reduction at 6–12 months. There was no statistically significant difference between each group pair in the cSDH thickness and volume reduction difference at all the follow-up intervals. Conclusions: A comparable efficiency of MMAE may be achieved in non-mature and mature as well as in spontaneous and traumatic cSDH, with an advantage for spontaneous cSDH at 6–12 months follow-up compared to traumatic cSDH. Traumatic cSDH may require a relatively long-term follow-up post-MMAE. cSDH thickness and volume, as parameters for pre- and post-MMAE cSDH evaluation, appear similar.
Purpose It was noticed that anterior choroidal artery (AChoA) aneurysms appear to rupture at relatively smaller sizes compared with aneurysms in other intracranial locations, based on anecdotal clinical experience. We therefore aimed to compare ruptured AChoA aneurysms with other ruptured aneurysms in other intracranial locations, pertaining to aneurysm dimensions. This may help in finding out if the rupture risk stratification, based on the amalgamation of aneurysms of multiple locations in one group, precisely estimates aneurysm rupture risk. Methods 255 ruptured intracranial aneurysms, which underwent assessment with catheter angiography with 3D reconstruction, in a single tertiary center between January 2000 and December 2023, were included. 6 aneurysm dimensions were compared. Results Statistically significant larger aneurysm maximum diameter, height, width and size ratio (SR) of the ruptured posterior communicating artery (PCOMM) aneurysms were identified when compared with ruptured AChoA aneurysms. No statistically significant difference in the aneurysm maximum diameter, height and width between the ruptured AChoA and ruptured anterior cerebral artery (ACA), anterior communicating artery (Acom), pericallosal artery and basilar tip aneurysms was found. AChoA aneurysms appear to rupture at a relatively small size, which is comparable to other aneurysm locations that are often grouped into different categories in rupture risk stratification. Conclusion More detailed location-specific rupture risk estimation may be needed. The combination of multiple intracranial aneurysm locations into a single category for risk stratification may not reflect the true aneurysm size at rupture for some aneurysms.
23 September 2025 in Journal of NeuroInterventional Surgery
Neurointerventionalists increasingly treat distal vascular targets with complex anatomy. Current guidewires require iterative hand shaping of the tip to navigate microcatheters and devices. Manual shaping often necessitates wire removal and reinsertion, risking wire damage, longer procedural times, increased vessel injury, and higher costs. The Artiria Medical SmartGUIDE 1 enables real time in situ tip deflection, allowing a single wire to reach a wide range of targets without manual reshaping. It can be locked in position to anchor microcatheters at branch points and prevent buckling or herniation, obviating the need for ancillary support devices, such as a balloon or metallic mesh. The wire can also shape and steer microcatheters on demand by torquing from within, potentially reducing risky maneuvers, such as looping within an aneurysm dome. We demonstrate the use of the deflectable Artiria Medical SmartGUIDE microwire in navigating through tortuous ophthalmic artery branches to perform preoperative embolization of highly vascular orbital tumor (video 1). We provide a comprehensive up to date comparison to other real-time steerable devices.2 3 4 5 6 7 Video 1 -Artiria Medical SmartGUIDE 0.014'' Deflectable-Tip Microwire:
BACKGROUND AND IMPORTANCE: Endovascular treatment of giant carotid cavernous aneurysms (GCCAs) may be associated with complications including rapid intrasaccular thrombosis, embolic ischemic stroke, and caroticocavernous fistula. CLINICAL PRESENTATION: A female in her 6th decade presented with a chronic, right partial abducens nerve palsy. Magnetic resononance angiography demonstrated a 25-mm right GCCA causing mass effect on the right cavernous sinus. Coil embolization of the aneurysm and parent vessel was performed after passing a balloon test occlusion. Final angiography demonstrated complete embolization of the aneurysm, however, absent ipsilateral cavernous sinus drainage, which was present previously. Intraprocedurally, the patient had ipsilateral proptosis and chemosis. Once extubated, urgent ophthalmology review documented preserved and symmetrical visual acuity with both pupils reactive to light. Intraocular pressure was 19-mm and 11-mm Hg in the right and left eye, respectively. The right eye had -2 abduction with otherwise intact extraocular movements. Acute management included a total of 16-mg IV dexamethasone on day 1, followed by a course of oral steroids and prophylactic low molecular weight heparin. Postprocedure computed tomography of the head demonstrated periorbital soft tissue edema and dilatation of the right superior ophthalmic vein, which peaked at 6 hours postprocedure. The patients' ocular findings and visual disturbances subsided within 36 hours postprocedure. The chronic partial abducens nerve palsy remained. CONCLUSION: Acute proptosis, chemosis, and visual disturbances may occur from mass effect on the cavernous sinus with venous outflow obstruction after GCCA embolization. This is thought to be secondary to increased mass effect from intrasaccular thrombosis and the large coil mass.