Pascal J. Mosimann

Prof. Dr. Pascal J. Mosimann

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JKJohannes Kaesmacher
Johannes Kaesmacher
JGJ. Gralla
J. Gralla
PMPascal J. Mosimann
Pascal J. Mosimann
FZF. Zibold
F. Zibold
Mirjam R HeldnerMirjam R Heldner
Mirjam R Heldner
PMP. Mordasini
P. Mordasini
BACKGROUND AND PURPOSE: In 5%–10% of patients with acute ischemic stroke with an intention to treat with mechanical thrombectomy, no reperfusion can be achieved (Thrombolysis in Cerebral Infarction score = 0/1). Purpose of this analysis was a systematic assessment of underlying reasons for reperfusion failures. MATERIALS AND METHODS: An intention-to-treat single-center cohort (n = 592) was re-evaluated for all patients in whom no reperfusion could be achieved (n = 63). Baseline characteristics of patients were compared between patients with and without reperfusion failures. After qualitative review of all cases with reperfusion failures, a classification system was proposed and relative frequencies were reported. In a second step, occurrence of delayed recanalization at 24 hours after reperfusion failure and dependency on IV-tPA were evaluated. RESULTS: In 63/592 patients with an intention to perform stent-retriever thrombectomy, no reperfusion was achieved (TICI 0/1, 10.6%, 95% CI, 8.2%–13.1%). Older patients (adjusted OR per yr = 1.03; 95% CI, 1.01–1.05) and patients with M2 occlusion (adjusted OR = 3.36; 95% CI, 1.82–6.21) were at higher risk for reperfusion failure. In most cases, no reperfusion was a consequence of technical difficulties (56/63, 88.9%). In one-third of these cases, reperfusion failures were due to the inability to reach the target occlusion (20/63, 31.7%), while “stent-retriever failure” occurred in 39.7% (25/63) of patients. Delayed recanalization was very rare (18.2%), without dependence on IV-tPA pretreatment status. CONCLUSIONS: Reasons for reperfusion failure in stent-retriever thrombectomy are heterogeneous. The failure to establish intracranial or cervical access is almost as common as stent-retriever failure after establishing intracranial access. Systematic reporting standards of reasons may help to further estimate relative frequencies and thereby guide priorities for technical development and scientific effort.

8 September 2020 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
MKMasaomi Koyanagi
Masaomi Koyanagi
PMPascal J. Mosimann
Pascal J. Mosimann
HNHannes Nordmeyer
Hannes Nordmeyer
MHMarkus Heddier
Markus Heddier
JKJuergen Krause
Juergen Krause
RCRené Chapot
René Chapot
Background Transvenous embolization of brain arteriovenous malformations (AVMs) can be curative. We aimed to evaluate the cure rate and safety of the transvenous retrograde pressure cooker technique (RPCT) using coils and n-butyl-2-cyanoacrylate as a venous plug. Methods All AVM patients treated via transvenous embolization between December 2004 and February 2017 in a single center were extracted from our database. Inclusion criteria were: inability to achieve transarterial cure alone; AVM < 3 cm; and single main draining vein. Outcome measures were immediate and 90 days' angiographic AVM occlusion rate, and morbidity and mortality at 30 days and 12 months, according to the modified Rankin Scale (mRS) score. Results Fifty-one patients (20 women; median age 47 years) were included. A majority (71%) were high grade (3 to 5 in the Spetzler–Martin classification). AVMs were deeply seated in 30 (59%) and cortical in 21 patients (41%). Thirty-three patients were previously embolized transarterially (65%). All patients but one were cured within a single session with the RPCT (96%). Cure was confirmed on follow-up digital subtraction angiography at 3 months in 82% of patients. Three patients experienced intracranial hemorrhage (6%), one requiring surgical evacuation. There were no deaths. One treatment-related major permanent deficit was observed (2.0%). Mean mRS before treatment, at 30 days, and 12 months after RPCT was 1.5, 1.5, and 1.3, respectively. Conclusions The retrograde pressure cooker technique can be curative in carefully selected high-grade AVMs. Long-term follow-up and prospective studies are needed to confirm our results.

18 June 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
TDT. Dobrocky
T. Dobrocky
AWA. Winklehner
A. Winklehner
PBP.S. Breiding
P.S. Breiding
LGL. Grunder
L. Grunder
GPG. Peschi
G. Peschi
EPEike Immo Piechowiak
Eike Immo Piechowiak
BACKGROUND AND PURPOSE: Spine MR imaging plays a pivotal role in the diagnostic work-up of spontaneous intracranial hypotension. The aim of this study was to compare the diagnostic accuracy of unenhanced spine MR imaging and intrathecal gadolinium-enhanced spine MR imaging for identification and localization of CSF leaks in patients with spontaneous intracranial hypotension. MATERIALS AND METHODS: A retrospective study of patients with spontaneous intracranial hypotension examined from February 2013 to October 2017 was conducted. Their spine MR imaging was reviewed by 3 blinded readers for the presence of epidural CSF using 3 different sequences (T2WI, 3D T2WI fat-saturated, T1WI gadolinium). In patients with leaks, the presumed level of the leak was reported. RESULTS: In total, 103 patients with spontaneous intracranial hypotension (63/103 [61%] women; mean age, 50 years) were evaluated. Seventy had a confirmed CSF leak (57/70 [81%] proved intraoperatively), and 33 showed no epidural CSF on multimodal imaging. Intrathecal gadolinium-enhanced spine MR imaging was nonsuperior to unenhanced spine MR imaging for the detection of epidural CSF (P = .24 and .97). All MR imaging sequences had a low accuracy for leak localization. In all patients, only 1 leakage point was present, albeit multiple suspicious lesions were reported in all sequences (mean, 5.0). CONCLUSIONS: Intrathecal gadolinium-enhanced spine MR imaging does not improve the diagnostic accuracy for the detection of epidural CSF. Thus, it lacks a rationale to be included in the routine spontaneous intracranial hypotension work-up. Heavily T2-weighted images with fat saturation provide high accuracy for the detection of an epidural CSF collection. Low accuracy for leak localization is due to an extensive CSF collection spanning several vertebrae (false localizing sign), lack of temporal resolution, and a multiplicity of suspicious lesions, albeit only a single leakage site is present. Thus, dynamic examination is mandatory before targeted treatment is initiated.

17 August 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
EPEike Immo Piechowiak
Eike Immo Piechowiak
FZF. Zibold
F. Zibold
TDT. Dobrocky
T. Dobrocky
PMPascal J. Mosimann
Pascal J. Mosimann
DBD. Bervini
D. Bervini
PMP. Mordasini
P. Mordasini
BACKGROUND AND PURPOSE: Combined transarterial balloon-assisted endovascular embolization with double-lumen balloon microcatheters and concomitant transvenous balloon protection was described as a promising treatment technique for dural arteriovenous fistulae of the transverse and sigmoid sinus. The purpose of this study was to evaluate the technical efficacy and safety of this combined treatment technique. MATERIALS AND METHODS: Nine consecutive patients presenting with dural arteriovenous fistulas of the transverse and sigmoid sinuses underwent combined transarterial and transvenous balloon-assisted endovascular embolization. Prospectively collected data were reviewed to assess the technical success rate, complication rate, and clinical outcome. RESULTS: Six patients presented with clinically symptomatic Borden type I, and 3 patients, with Borden type II dural arteriovenous fistulas of the transverse and sigmoid sinuses (3 men, 6 women; mean age, 50.4 years). Transarterial embolization was performed with a double-lumen balloon with Onyx and concomitant transvenous sinus protection with a dedicated venous remodeling balloon. Complete angiographic occlusion at the latest follow-up (mean, 4.8 months) was achieved in 6 patients, and near-complete occlusion, in 2 patients. Clinical cure or remission of symptoms was obtained in 6 and 2 patients, respectively. One patient with a residual fistula underwent further treatment in which the dural arteriovenous fistula was cured by sinus occlusion. Complete occlusion of the dural arteriovenous fistula was visible on the follow-up angiography after final treatment in 8 patients. One patient refused follow-up angiography but was free of symptoms. There were no immediate or delayed postinterventional complications. CONCLUSIONS: Transarterial balloon-assisted embolization of dural arteriovenous fistulas of the transverse and sigmoid sinuses with combined transvenous balloon protection is safe and offers a high rate of complete dural arteriovenous fistula occlusion and remission of clinical symptoms.

19 January 2021 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
RRReza Rikhtegar
Reza Rikhtegar
PMPascal J. Mosimann
Pascal J. Mosimann
RWRalph Weber
Ralph Weber
MWMarta Wallocha
Marta Wallocha
EYElif Yamac
Elif Yamac
RCRené Chapot
René Chapot
Background Recent progress with smaller retrievers has expanded the ability to reach distal brain arteries. We herein report recanalization, bleeding complications and short-term clinical outcomes with the smallest currently known low profile thrombectomy device in patients with primary or secondary distal medium vessel occlusion (DMVO). Methods We performed a retrospective analysis of 115 patients receiving mechanical thrombectomy (MT) in DMVO using the extended Thrombolysis in Cerebral Infarction (eTICI), European Cooperative Acute Stroke Study (ECASS) II classification, The National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores at admission and discharge to evaluate outcomes. Patients were stratified into three groups: (1) primary isolated distal occlusion (n=34), (2) secondary distal occlusion after MT of a proximal vessel occlusion (n=71), or (3) during endovascular treatment of aneurysms or arteriovenous malformations (AVMs) (n=10). Results Successful distal recanalization, defined as an eTICI score of 2b67, 2c and 3, was achieved in 74.7% (86/115) of patients. More specifically, it was 70.5% (24/34), 73.2% (52/71), and 100% (10/10) of primary DMVO, secondary DMVO after proximal MT, and rescue MT during aneurysm or AVM embolization, respectively. Symptomatic intraparenchymal bleeding occurred in 6.9% (eight patients). In-hospital mortality occurred in 18.1% (19/105) of patients with stroke. The most common cause of death was large infarct, old age, and therapy limitation. Conclusion Direct or rescue MT of DMVO using a very low profile thrombectomy device is associated with a high rate of successful recanalization and a reasonable rate of symptomatic hemorrhagic complication, despite a risk of 18.1% hospital mortality in elderly patients. Further trials are needed to confirm our results and assess long-term clinical outcomes.

22 October 2025 in Science Robotics
Verified
Journal Article
Closed access
LPLucio Pancaldi
Lucio Pancaldi
EÖEce Özelçi
Ece Özelçi
MGMehdi Ali Gadiri
Mehdi Ali Gadiri
JRJulian Raub
Julian Raub
PMPascal J. Mosimann
Pascal J. Mosimann
MSMahmut Selman Sakar
Mahmut Selman Sakar
Minimally invasive interventions performed inside brain vessels with the synergistic use of microcatheters pushed over guidewires have revolutionized the way aneurysms, strokes, arteriovenous malformations, brain tumors, and other cerebrovascular conditions are being treated. However, a substantial portion of the brain vasculature remains inaccessible because the conventional catheterization technique based on transmitting forces from the proximal to the distal end of the instruments imposes stringent constraints on their diameter and stiffness. Here, we overcame this mechanical barrier by microengineering ultraminiaturized magnetic microcatheters in the form of an inflatable flat tube, making them ultraflexible and capable of harnessing the kinetic energy of blood flow for endovascular navigation. We introduce a compact and versatile magnetic steering platform that is compatible with conventional biplane fluoroscope imaging and demonstrate safe and effortless navigation and tracking of hard-to-reach, distal, tortuous arteries that are as small as 180 micrometers in diameter with a curvature radius as small as 0.69 millimeters. Furthermore, we demonstrate the superselective infusion of contrast and embolic liquid agents, all in a porcine model. These results pave the way to reach, diagnose, and treat currently inaccessible distal arteries that may be at risk of bleeding or feeding a tumor. Our endovascular technology can also be used to selectively target tissues for drug or gene delivery from within the arteries, not only in the central and peripheral nervous systems but also in almost any other organ system, with improved accuracy, speed, and safety.