María Rodríguez-García

Mrs. María Rodríguez-García


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2025 in Molecules
Verified
Journal Article
Open access
PDF file
MRMaría Rodríguez-García
María Rodríguez-García
IMIrene Martínez
Irene Martínez
IAIrene Aliart
Irene Aliart
JMJaime I. Sainz de Medrano
Jaime I. Sainz de Medrano
NRNaira Rico
Naira Rico
GCGregori Casals
Gregori Casals
Accurate quantification of indoxyl sulfate (IndS) and p-cresyl sulfate (pCS) is essential for understanding their role in chronic kidney disease (CKD) progression and for developing strategies to mitigate their harmful effects, including cardiovascular morbidity and renal fibrosis. Advances in liquid chromatography–high-resolution mass spectrometry (LC–HRMS) enable the integration of powerful diagnostic tools into clinical laboratories. Along with accurate quantification, precise mass measurements allow for untargeted compound identification. Methods. An LC–HRMS was validated for quantifying IndS and pCS in human serum, following EMA guidelines. The method involved protein precipitation with methanol, micro-LC for chromatographic separation, and detection based on accurate mass, with simultaneous high-resolution full-scan acquisition. Clinical samples from patients with varying degrees of renal insufficiency and samples obtained before and after hemodiafiltration were analyzed. Results. The method demonstrated acceptable linearity, precision, and accuracy. The measurement range for both analytes was from 100 to 40,000 ng/mL. Serum levels of IndS and pCS correlated with decreased renal function. After hemodiafiltration, there was a significant reduction of IndS (50%) and pCS (43%). Simultaneous untargeted analysis allowed to identify metabolites significantly underexpressed after hemodiafiltration. Conclusions. An accurate LC–HRMS method was validated for the quantification of IndS and pCS serum levels in patients with CKD, providing insights into toxin dynamics and enabling untargeted metabolic evaluation.

14 January 2025 in Membranes
Verified
Journal Article
Open access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
VSVíctor Joaquín Escudero Saiz
Víctor Joaquín Escudero Saiz
ECElena Cuadrado-Payán
Elena Cuadrado-Payán
MRMaría Rodríguez-García
María Rodríguez-García
MGMiquel Gomez
Miquel Gomez
JBJose Jesus Broseta
Jose Jesus Broseta
The dialysis membrane based on a hydrophilic polymer (Hydrolink NV) was designed to enhance the movement of adsorbed water at the blood–membrane interface, aiming to achieve antithrombogenic and antifouling effects. This study aimed to assess the performance and albumin loss of the Hydrolink NV dialyzer in hemodialysis (HD) and post-dilution hemodiafiltration (HDF) with different infusion flows (Qis) and compare it with the hydrophilic FX CorAL dialyzer in post-dilution HDF. A prospective study was carried out in 20 patients. Patients underwent five dialysis sessions with the same routine dialysis parameters: four sessions with the Toraylight NV 2.1 (HD, post-dilution HDF with 50, 75 or auto-substitution Qi) and one with the FX CorAL 800 (post-dilution HDF with auto-substitution Qi). The reduction ratios’ (RRs’) wide range of molecular weight molecules were assessed and the dialysate albumin loss was quantified. The lowest β2-microglobulin, indoxyl-sulfate, and p-cresyl sulfate RR values were observed with the Toraylight NV 2.1 in HD, and they improved progressively with an increased Qi, without differences being observed between the two dialyzers in auto-substitution. A different removal profile was observed in terms of myoglobin, kFLC, prolactin, α1-microglobulin, α1-acid glycoprotein, and λFLC, whose RRs also improved progressively with an increased Qi but were significantly higher with the Toraylight NV than the CorAL in the same convective condition. There were significant differences in the albumin dialysate losses, with the highest value obtained with the Toraylight NV in auto-substitution HDF, with more than 50% of patients surpassing 5 g per session. The Toraylight NV dialyzer has great potential for efficacy but should be used at the optimal convective volume (Qi not exceeding 75 mL/min or FF not exceeding 25%) to avoid excessive albumin loss.

3 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
DRDiana Rodríguez-Espinosa
Diana Rodríguez-Espinosa
ECElena Cuadrado-Payán
Elena Cuadrado-Payán
NRNaira Rico
Naira Rico
MTMercè Torra
Mercè Torra
RFRosa María Fernández
Rosa María Fernández
JBJose Jesus Broseta
Jose Jesus Broseta
The choice of dialysate buffer in hemodialysis is crucial, with acetate being widely used despite complications. Citrate has emerged as an alternative due to its favorable effects, yet concerns persist about its impact on calcium and magnesium levels. This study investigates the influence of citrate dialysate (CD) with and without additional magnesium supplementation on CKD-MBD biomarkers and assesses their ability to chelate divalent metals compared to acetate dialysates (AD). A prospective crossover study was conducted in a single center, involving patients on thrice-weekly online hemodiafiltration (HDF). Four dialysates were compared: two acetate-based and two citrate-based. Various biochemical parameters were monitored before and after each dialysis session. Seventy-two HDF sessions were performed in eighteen patients. CD showed stability in iPTH levels and reduced post-dialysis total calcium, with no significant increase in adverse events. Magnesium supplementation with CD prevented hypomagnesemia. However, no significant differences among dialysates were observed in the chelation of other divalent metals. Citrate dialysates, particularly with higher magnesium concentrations, offer promising benefits, including prevention of hypomagnesemia and stabilization of CKD-MBD parameters, suggesting citrate as a viable alternative to acetate. Further studies are warranted to elucidate long-term outcomes and optimize dialysate formulations.

15 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
MRMaría Rodríguez-García
María Rodríguez-García
GFGuillermo Fernández-Varo
Guillermo Fernández-Varo
SHSusana Hidalgo
Susana Hidalgo
GRGabriela Rodríguez
Gabriela Rodríguez
IMIrene Martínez
Irene Martínez
GCGregori Casals
Gregori Casals
Circulating levels of 2-hydroxybutyrate (2HB) are highly related to glycemic status in different metabolomic studies. According to recent evidence, 2HB is an early biomarker of the future development of dysglycemia and type 2 diabetes mellitus and may be causally related to the progression of normal subjects to impaired fasting glucose or insulin resistance. In the present study, we developed and validated a simple, specific and sensitive gas chromatography-mass spectrometry (GC-MS) method specifically intended to quantify serum levels of 2HB. Liquid–liquid extraction with ethyl acetate was followed by 2 min of microwave-assisted derivatization. The method presented acceptable accuracy, precision and recovery, and the limit of quantification was 5 µM. Levels of 2HB were found to be stable in serum after three freeze-thaw cycles, and at ambient temperature and at a temperature of 4 °C for up to 24 h. Extracts derivatized under microwave irradiation were stable for up to 96 h. No differences were found in 2HB concentrations measured in serum or plasma EDTA samples. In summary, the method is useful for a rapid, precise and accurate quantification of 2HB in serum samples assessed for the evaluation of dysglycemia and diabetes mellitus.

16 December 2024 in Toxins
Verified
Journal Article
Open access
PDF file
VSVíctor Joaquín Escudero Saiz
Víctor Joaquín Escudero Saiz
ECElena Cuadrado-Payán
Elena Cuadrado-Payán
MRMaría Rodríguez-García
María Rodríguez-García
GCGregori Casals
Gregori Casals
LRLida M Rodas
Lida M Rodas
Francisco MaduellFrancisco Maduell
Francisco Maduell
Pain is a frequent and disturbing symptom among hemodialysis patients. Protein-bound uremic toxins (PBUTs) are related to cardiovascular and overall mortality, and they are difficult to remove with current hemodialysis treatments. The PBUT displacers, such as furosemide, tryptophan, or ibuprofen, may be promising new strategies for improving their clearance. This study aims to compare ibuprofen versus other analgesic drugs in PBUT removal. A prospective study was carried out in 23 patients. Patients underwent four dialysis sessions with routine dialysis parameters, except for analgesic drugs administered (lysine acetylsalicylic acid, acetaminophen, dexketoprofen, and ibuprofen). The reduction ratios (RRs) of a wide range of molecular weight molecules were assessed, including total p-cresyl sulfate and total indoxyl-sulfate. There were no complications related to the administered drug, and pain was controlled independently of the drug. There were no differences in the RR of small-size and medium-sized molecules between all four study treatments. However, indoxyl sulfate and p-cresyl sulfate RRs when ibuprofen was administered were significantly higher than lysine acetylsalicylic acid, acetaminophen, and dexketoprofen treatments. In conclusion, patients with pain may benefit from treatment with ibuprofen instead of lysine acetylsalicylic acid, paracetamol, or dexketoprofen, since in addition to improving pain, it increases the removal of PBUTs.

1 October 2024 in Toxins
Verified
Journal Article
Open access
PDF file
DRDiana Rodríguez-Espinosa
Diana Rodríguez-Espinosa
ECElena Cuadrado-Payán
Elena Cuadrado-Payán
NRNaira Rico
Naira Rico
MTMercè Torra
Mercè Torra
RFRosa María Fernández
Rosa María Fernández
JBJose Jesus Broseta
Jose Jesus Broseta
Modern hemodialysis employs weak acids as buffers to prevent bicarbonate precipitation with calcium or magnesium. Acetate, the most used acid, is linked to chronic inflammation and poor dialysis tolerance. Citrate has emerged as a potential alternative, though its effect on dialysis efficiency is not clear. This study aims to compare the efficacy of acetate- and citrate-based dialysates, focusing on protein-bound uremic toxins and dialysis doses. This single-center prospective crossover study includes prevalent patients participating in a thrice-weekly online hemodiafiltration program. Four dialysates were tested: two acetate-based (1.25 and 1.5 mmol/L calcium) and two citrate-based (1.5 mmol/L calcium with 0.5 and 0.75 mmol/L magnesium). Pre- and post-dialysis blood samples of eighteen patients were analyzed for urea, creatinine, p-cresyl sulfate, indoxyl sulfate, and albumin. Statistical significance was assessed using paired t-tests and repeated measures of ANOVA. There were no significant differences in dialysis dose (Kt), urea, creatinine, or indoxyl sulfate reduction ratios between acetate- and citrate-based dialysates. However, a significant decrease in the reduction ratio of p-cresyl sulfate was observed with the acetate dialysate containing 1.25 mmol/L calcium and the citrate dialysate with 0.5 mmol/L magnesium compared to the acetate dialysate containing 1.5 mmol/L calcium and the citrate dialysate with 0.75 mmol/L magnesium (51.56 ± 4.75 and 53.02 ± 4.52 vs. 65.25 ± 3.38 and 58.66 ± 4.16, p 0.007). No differences in dialysis dose were found between acetate- and citrate-based dialysates. However, citrate dialysates with lower calcium and magnesium concentrations may reduce the albumin displacement of p-cresyl sulfate. Further studies are needed to understand the observed differences and optimize the dialysate composition for the better clearance of protein-bound uremic toxins.