Michael Lommel

Mr. Michael Lommel

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2016 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
CSChan Yong Schüle
Chan Yong Schüle
BTBente Thamsen
Bente Thamsen
BBBastian Blümel
Bastian Blümel
MLMichael Lommel
Michael Lommel
TKTamer Karakaya
Tamer Karakaya
UKUlrich Kertzscher
Ulrich Kertzscher

7 June 2021 in Indoor Air
Verified
Journal Article
Open access
PDF file
MLMichael Lommel
Michael Lommel
VFVera Froese
Vera Froese
MSMoritz Sieber
Moritz Sieber
MJMarvin Jentzsch
Marvin Jentzsch
TBTim Bierewirtz
Tim Bierewirtz
CPChristian Oliver Paschereit
Christian Oliver Paschereit
The SARS-CoV-2 pandemic has created a great demand for a better understanding of the spread of viruses in indoor environments. A novel measurement system consisting of one portable aerosol-emitting mannequin (emitter) and a number of portable aerosol-absorbing mannequins (recipients) was developed that can measure the spread of aerosols and droplets that potentially contain infectious viruses. The emission of the virus from a human is simulated by using tracer particles solved in water. The recipients inhale the aerosols and droplets and quantify the level of solved tracer particles in their artificial lungs simultaneously over time. The mobile system can be arranged in a large variety of spreading scenarios in indoor environments and allows for quantification of the infection probability due to airborne virus spreading. This study shows the accuracy of the new measurement system and its ability to compare aerosol reduction measures such as regular ventilation or the use of a room air purifier.

26 December 2023 in Artificial Organs
Verified
Journal Article
Open access
VFVera Froese
Vera Froese
LGLeonid Goubergrits
Leonid Goubergrits
UKUlrich Kertzscher
Ulrich Kertzscher
MLMichael Lommel
Michael Lommel
Background: The study of blood trauma, such as hemolysis in blood‐carrying devices, is crucial due to the high incidence of adverse events like alteration of blood function, bleeding, and multi‐organ failure. The extent of flow‐induced hemolysis, predominantly influenced by stress duration and intensity, is described by established model parameters based on the power law approach. In recent years, various parameters were determined using different Couette shearing devices and donor species. However, they have not been validated due to limited experimental data.Methods: This study provides hemolysis measurements in a Couette shearing device and evaluates the suitability of different power law parameters. The revised Couette shearing device generates well‐defined dynamic stress loads that are repeatedly applied to blood samples at a defined temperature. Human blood samples with an adjusted hematocrit of 30%, were tested with varying repetitions (20 to 80 times). The half‐sinusoidal stress loads had amplitudes of 73 to 140 Pa and exposure times of 24 msec per repetition. The parameters of five common power law hemolysis approaches were then compared with the experimental data.Results: The prediction with the power law model parameters C = 3.458 × 10−6, α = 0.2777 and β = 2.0639 showed a good agreement with the experimental results.Conclusion: The effect of multiple short‐time stresses on hemolysis was investigated to validate the power law hemolysis model with the Couette shearing device of this study.

24 November 2021 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
EKEriselda Keshi
Eriselda Keshi
PTPeter Tang
Peter Tang
MWMarie Weinhart
Marie Weinhart
HEHannah Everwien
Hannah Everwien
SMSimon Moosburner
Simon Moosburner
KHKarl Herbert Hillebrandt
Karl Herbert Hillebrandt
Background: Since autologous veins are unavailable when needed in more than 20% of cases in vascular surgery, the production of personalized biological vascular grafts for implantation has become crucial. Surface modification of decellularized xenogeneic grafts with vascular cells to achieve physiological luminal coverage and eventually thromboresistance is an important prerequisite for implantation. However, ex vivo thrombogenicity testing remains a neglected area in the field of tissue engineering of vascular grafts due to a multifold of reasons. Methods: After seeding decellularized bovine carotid arteries with human endothelial progenitor cells and umbilical cord-derived mesenchymal stem cells, luminal endothelial cell coverage (LECC) was correlated with glucose and lactate levels on the cell supernatant. Then a closed loop whole blood perfusion system was designed. Recellularized grafts with a LECC > 50% and decellularized vascular grafts were perfused with human whole blood for 2 h. Hemolysis and complete blood count evaluation was performed on an hourly basis, followed by histological and immunohistochemical analysis. Results: While whole blood perfusion of decellularized grafts significantly reduced platelet counts, platelet depletion from blood resulting from binding to re-endothelialized grafts was insignificant (p = 0.7284). Moreover, macroscopic evaluation revealed thrombus formation only in the lumen of unseeded grafts and histological characterization revealed lack of CD41 positive platelets in recellularized grafts, thus confirming their thromboresistance. Conclusion: In the present study we were able to demonstrate the effect of surface modification of vascular grafts in their thromboresistance in an ex vivo whole blood perfusion system. To our knowledge, this is the first study to expose engineered vascular grafts to human whole blood, recirculating at high flow rates, immediately after seeding.

3 September 2025 in IEEE Communications Surveys & Tutorials
Verified
Journal Article
Closed access
SBSunasheer Bhattacharjee
Sunasheer Bhattacharjee
DBDadi Bi
Dadi Bi
PHPit Hofmann
Pit Hofmann
AWAlexander Wietfeld
Alexander Wietfeld
SBSophie Becke
Sophie Becke
FDFalko Dressler
Falko Dressler
Molecular Communication (MC) has long been envisioned to enable an Internet of Bio-Nano Things (IoBNT) with medical applications, where nanomachines within the human body conduct monitoring, diagnosis, and therapy at micro- and nanoscale levels. MC involves information transfer via molecules and is supported by well-established theoretical models. However, practically achieving reliable, energy-efficient, and bio-compatible communication at these scales still remains a challenge. Air-Based Molecular Communication (ABMC) is a type of MC that operates over larger, meter-scale distances and extends even outside the human body. Therefore, devices and techniques to realize ABMC are readily accessible, and associated use cases can be very promising in the near future. Exhaled breath analysis has previously been proposed. It provides a non-invasive approach for health monitoring, leveraging existing commercial sensor technologies and reducing deployment barriers. The breath contains a diverse range of molecules and particles that serve as biomarkers linked to various physiological and pathological conditions. The plethora of proven methods, models, and optimization approaches in MC enable macroscale breath analysis, treating humans as the transmitter, the breath as the information carrier, and macroscale sensors as the receiver. Using ABMC to interface with the inherent dynamic networks of cells, tissues, and organs could create a novel Internet of Bio Things (IoBT), a preliminary macroscale stage of the IoBNT. This survey extensively reviews exhaled breath modeling and analysis through the lens of MC, offering insights into theoretical frameworks and practical implementations from ABMC, bringing the IoBT a step closer to real-world use.

16 April 2025 in Artificial Organs
Verified
Journal Article
Open access
MLMichael Lommel
Michael Lommel
VFVera Froese
Vera Froese
HWHenri Wolff
Henri Wolff
NDNico Dirkes
Nico Dirkes
KVKatharina Vellguth
Katharina Vellguth
UKUlrich Kertzscher
Ulrich Kertzscher
Background: Although flow simulations have become more accurate, hemolysis prediction models still show large deviations from measured values in blood‐carrying devices. To develop and validate more accurate models, specific hemolysis experiments are needed to determine the influence of parameters on hemolysis, such as stress type and exposure time typical for rotary blood pumps (RBPs). Methods: In order to investigate the applicability of the hemolysis models to the flow in RBPs, this study performed experiments with human whole blood in three differently shaped flow channels that generate short‐term stress peaks. CFD simulations were performed and the applicability of the stress‐based and strain‐based hemolysis models was investigated by comparing them with the experimental results. Results: Low and statistically non‐significant hemolysis was measured for all geometries and 1200 load repetitions. The CFD simulations determined scalar shear stresses up to 1500 Pa with exposure times in the millisecond range. The stress‐based hemolysis model overestimated hemolysis by several orders of magnitude and predicted significant differences between the three flow channels. The strain‐based hemolysis model predicted low and approximately equal hemolysis, in agreement with the experimental results. Conclusion: The results suggest that the stress‐based hemolysis model is not appropriate for the applied short‐term stress peaks. The strain‐based model, which considers the deformation of the RBCs over time, appears to be more appropriate for this type of flow. This implies a similar relationship for RBPs, where these short‐term stress peaks are typical.