Ulrich Kertzscher

Ulrich Kertzscher

Auto-generated profile, based on publicly available information

Ulrich Kertzscher

Institute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charit, CharitUniversittsmedizin Berlin, Berlin, Germany

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2016 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
CSChan Yong Schüle
Chan Yong Schüle
BTBente Thamsen
Bente Thamsen
BBBastian Blümel
Bastian Blümel
MLMichael Lommel
Michael Lommel
TKTamer Karakaya
Tamer Karakaya
UKUlrich Kertzscher
Ulrich Kertzscher

21 February 2011 in Atherosclerosis
Verified
Journal Article
Closed access
PDF file
EWErnst Wellnhofer
Ernst Wellnhofer
JOJan Osman
Jan Osman
UKUlrich Kertzscher
Ulrich Kertzscher
KAKlaus Affeld
Klaus Affeld
EFEckart Fleck
Eckart Fleck
LGLeonid Goubergrits
Leonid Goubergrits

26 December 2023 in Artificial Organs
Verified
Journal Article
Open access
VFVera Froese
Vera Froese
LGLeonid Goubergrits
Leonid Goubergrits
UKUlrich Kertzscher
Ulrich Kertzscher
MLMichael Lommel
Michael Lommel
Background: The study of blood trauma, such as hemolysis in blood‐carrying devices, is crucial due to the high incidence of adverse events like alteration of blood function, bleeding, and multi‐organ failure. The extent of flow‐induced hemolysis, predominantly influenced by stress duration and intensity, is described by established model parameters based on the power law approach. In recent years, various parameters were determined using different Couette shearing devices and donor species. However, they have not been validated due to limited experimental data.Methods: This study provides hemolysis measurements in a Couette shearing device and evaluates the suitability of different power law parameters. The revised Couette shearing device generates well‐defined dynamic stress loads that are repeatedly applied to blood samples at a defined temperature. Human blood samples with an adjusted hematocrit of 30%, were tested with varying repetitions (20 to 80 times). The half‐sinusoidal stress loads had amplitudes of 73 to 140 Pa and exposure times of 24 msec per repetition. The parameters of five common power law hemolysis approaches were then compared with the experimental data.Results: The prediction with the power law model parameters C = 3.458 × 10−6, α = 0.2777 and β = 2.0639 showed a good agreement with the experimental results.Conclusion: The effect of multiple short‐time stresses on hemolysis was investigated to validate the power law hemolysis model with the Couette shearing device of this study.

22 December 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MBMoritz Bender
Moritz Bender
AEAndreas Escher
Andreas Escher
Barbara MessnerBarbara Messner
Barbara Messner
MRMichael Röhrich
Michael Röhrich
MFMichael Bernhard Fischer
Michael Bernhard Fischer
Marcus GraneggerMarcus Granegger
Marcus Granegger
Objective: Conventional mock circulatory loops (MCLs) cannot replicate realistic hemodynamic conditions without inducing blood trauma. This constrains in-vitro hemocompatibility examinations of blood pumps to static test loops that do not mimic clinical scenarios. This study aimed at developing an atraumatic MCL based on a hardware-in-the-loop concept (H-MCL) for realistic hemocompatibility assessment. Methods: The H-MCL was designed for 450 $\pm$ 50 ml of blood with the polycarbonate reservoirs, the silicone/polyvinyl-chloride tubing, and the blood pump under investigation as the sole blood-contacting components. To account for inherent coupling effects a decoupling pressure control was derived by feedback linearization, whereas the level control was addressed by an optimization task to overcome periodic loss of controllability. The HeartMate 3 was showcased to evaluate the H-MCL's accuracy at typical hemodynamic conditions. To verify the atraumatic properties of the H-MCL, hemolysis (bovine blood, n = 6) was evaluated using the H-MCL in both inactive (static) and active (minor pulsatility) mode, and compared to results achieved in conventional loops. Results: Typical hemodynamic scenarios were replicated with marginal coupling effects and root mean square error (RMSE) below 1.74 $\pm$ 1.37 mmHg while the fluid level remained within $\pm$ 4% of its target value. The normalized indices of hemolysis (NIH) for the inactive H-MCL showed no significant differences to conventional loops ( $\Delta$ NIH = −1.6 mg/100 L). Further, no significant difference was evident between the active and inactive mode in the H-MCL ( $\Delta$ NIH = +0.3 mg/100 L). Conclusion and significance: Collectively, these findings indicated the H-MCL's potential for in-vitro hemocompatibility assessment of blood pumps within realistic hemodynamic conditions, eliminating inherent setup-related risks for blood trauma.

3 September 2025 in IEEE Communications Surveys & Tutorials
Verified
Journal Article
Closed access
SBSunasheer Bhattacharjee
Sunasheer Bhattacharjee
DBDadi Bi
Dadi Bi
PHPit Hofmann
Pit Hofmann
AWAlexander Wietfeld
Alexander Wietfeld
SBSophie Becke
Sophie Becke
FDFalko Dressler
Falko Dressler
Molecular Communication (MC) has long been envisioned to enable an Internet of Bio-Nano Things (IoBNT) with medical applications, where nanomachines within the human body conduct monitoring, diagnosis, and therapy at micro- and nanoscale levels. MC involves information transfer via molecules and is supported by well-established theoretical models. However, practically achieving reliable, energy-efficient, and bio-compatible communication at these scales still remains a challenge. Air-Based Molecular Communication (ABMC) is a type of MC that operates over larger, meter-scale distances and extends even outside the human body. Therefore, devices and techniques to realize ABMC are readily accessible, and associated use cases can be very promising in the near future. Exhaled breath analysis has previously been proposed. It provides a non-invasive approach for health monitoring, leveraging existing commercial sensor technologies and reducing deployment barriers. The breath contains a diverse range of molecules and particles that serve as biomarkers linked to various physiological and pathological conditions. The plethora of proven methods, models, and optimization approaches in MC enable macroscale breath analysis, treating humans as the transmitter, the breath as the information carrier, and macroscale sensors as the receiver. Using ABMC to interface with the inherent dynamic networks of cells, tissues, and organs could create a novel Internet of Bio Things (IoBT), a preliminary macroscale stage of the IoBNT. This survey extensively reviews exhaled breath modeling and analysis through the lens of MC, offering insights into theoretical frameworks and practical implementations from ABMC, bringing the IoBT a step closer to real-world use.

21 August 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
TBTim Bierewirtz
Tim Bierewirtz
KNKrishnaraj Narayanaswamy
Krishnaraj Narayanaswamy
RGRosario Giuffrida
Rosario Giuffrida
TRTim Rese
Tim Rese
DBDominik Bortis
Dominik Bortis
Marcus GraneggerMarcus Granegger
Marcus Granegger
Objective :Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH ( ShuttlePump ). Methods: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. Results: Pump characteristics cover the entire required operating range for a TAH, providing 2.5 – 9 L/min of flow rate against 50 – 160 mmHg arterial pressures at stroke frequencies of 1.5 – 5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of < 2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100L, and 95% of the pump's blood volume was exchanged after 1.42 s. Conclusion and significance: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump