Lutz Scheideler

Dr. Lutz Scheideler

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
XHXingting Han
Xingting Han
DYDong Yang
Dong Yang
CYChuncheng Yang
Chuncheng Yang
SSSebastian Spintzyk
Sebastian Spintzyk
LSLutz Scheideler
Lutz Scheideler
FRFrank Rupp
Frank Rupp
Fused deposition modeling (FDM) is a rapidly growing three-dimensional (3D) printing technology and has great potential in medicine. Polyether-ether-ketone (PEEK) is a biocompatible high-performance polymer, which is suitable to be used as an orthopedic/dental implant material. However, the mechanical properties and biocompatibility of FDM-printed PEEK and its composites are still not clear. In this study, FDM-printed pure PEEK and carbon fiber reinforced PEEK (CFR-PEEK) composite were successfully fabricated by FDM and characterized by mechanical tests. Moreover, the sample surfaces were modified with polishing and sandblasting methods to analyze the influence of surface roughness and topography on general biocompatibility (cytotoxicity) and cell adhesion. The results indicated that the printed CFR-PEEK samples had significantly higher general mechanical strengths than the printed pure PEEK (even though there was no statistical difference in compressive strength). Both PEEK and CFR-PEEK materials showed good biocompatibility with and without surface modification. Cell densities on the “as-printed” PEEK and the CFR-PEEK sample surfaces were significantly higher than on the corresponding polished and sandblasted samples. Therefore, the FDM-printed CFR-PEEK composite with proper mechanical strengths has potential as a biomaterial for bone grafting and tissue engineering applications.

Verified
Journal Article
Open access
PDF file
Ping LiPing Li
Ping Li
CSChristine Schille
Christine Schille
ESErnst Schweizer
Ernst Schweizer
FRFrank Rupp
Frank Rupp
AHAlexander Heiss
Alexander Heiss
LSLutz Scheideler
Lutz Scheideler
Zn-based biodegradable metallic materials have been regarded as new potential biomaterials for use as biodegradable implants, mainly because of the ideal degradation rate compared with those of Mg-based alloys and Fe-based alloys. In this study, we developed and investigated a novel Zn-4 wt % Ag alloy as a potential biodegradable metal. A thermomechanical treatment was applied to refine the microstructure and, consequently, to improve the mechanical properties, compared to pure Zn. The yield strength (YS), ultimate tensile strength (UTS) and elongation of the Zn-4Ag alloy are 157 MPa, 261 MPa, and 37%, respectively. The corrosion rate of Zn-4Ag calculated from released Zn ions in DMEM extracts is approximately 10.75 ± 0.16 μg cm–2 day–1, which is higher than that of pure Zn. In vitro cytotoxicity tests showed that the Zn-4Ag alloy exhibits acceptable toxicity to L929 and Saos-2 cells, and could effectively inhibit initial bacteria adhesion. This study shows that the Zn-4Ag exhibits excellent mechanical properties, predictable degradation behavior, acceptable biocompatibility, and effective antibacterial properties, which make it a candidate biodegradable material.

Verified
Journal Article
Open access
PDF file
XHXingting Han
Xingting Han
Neha SharmaNeha Sharma
Neha Sharma
ZXZeqian Xu
Zeqian Xu
LSLutz Scheideler
Lutz Scheideler
JGJürgen Geis-Gerstorfer
Jürgen Geis-Gerstorfer
SSSebastian Spintzyk
Sebastian Spintzyk
Polyetheretherketone (PEEK) is a prime candidate to replace metallic implants and prostheses in orthopedic, spine and cranio-maxillofacial surgeries. Fused-filament fabrication (FFF) is an economical and efficient three-dimensional (3D) printing method to fabricate PEEK implants. However, studies pertaining to the bioactivity of FFF 3D printed PEEK are still lacking. In this study, FFF 3D printed PEEK samples were fabricated and modified with polishing and grit-blasting (three alumina sizes: 50, 120, and 250 µm) to achieve varying levels of surface roughness. In vitro cellular response of a human osteosarcoma cell line (SAOS-2 osteoblasts, cell adhesion, metabolic activity, and proliferation) on different sample surfaces of untreated, polished, and grit-blasted PEEK were evaluated. The results revealed that the initial cell adhesion on different sample surfaces was similar. However, after 5 days the untreated FFF 3D printed PEEK surfaces exhibited a significant increase in cell metabolic activity and proliferation with a higher density of osteoblasts compared with the polished and grit-blasted groups (p < 0.05). Therefore, untreated FFF 3D printed PEEK with high surface roughness and optimal printing structures might have great potential as an appropriate alloplastic biomaterial for reconstructive cranio-maxillofacial surgeries.

22 September 2018 in Materials
Verified
Journal Article
Open access
PDF file
XHXingting Han
Xingting Han
Tomofumi SawadaTomofumi Sawada
Tomofumi Sawada
CSChristine Schille
Christine Schille
ESErnst Schweizer
Ernst Schweizer
LSLutz Scheideler
Lutz Scheideler
SSSebastian Spintzyk
Sebastian Spintzyk
Cobalt-chromium (Co-Cr) alloy is a widely used base material for dental fixed prostheses. These restorations can be produced through casting technique, subtractive or additive manufacturing technologies. However, limited information is available regarding the influence of manufacturing techniques on the properties of Co-Cr alloy since most studies used different chemical compositions of Co-Cr alloy for different manufacturing methods. This study compares the mechanical properties, metal-ceramic bond strength, and microstructures of specimens produced by casting, milling, and selective laser melting (SLM) from one single Co-Cr alloy composition. The mechanical properties of the alloy were investigated by tensile and Vickers hardness tests, and metal-ceramic bond strength was determined by three-point bending. Scanning electron microscopy (SEM) with backscattered electron (BSE) images and optical microphotographs were used to analyze the surface microstructures. Compared with the casting and milling techniques, SLM Co-Cr alloy specimens indicated enhanced mechanical properties and comparable metal-ceramic bond strength. Besides, the microstructures of the SLM specimens showed finer grains with more second phase particles than the casting and milling specimens. The results of our study indicate that SLM might be superior to traditional techniques for the manufacturing of fixed dental restorations.

1 October 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
Ping LiPing Li
Ping Li
CSChristine Schille
Christine Schille
ESErnst Schweizer
Ernst Schweizer
EKEvi Kimmerle-Müller
Evi Kimmerle-Müller
FRFrank Rupp
Frank Rupp
LSLutz Scheideler
Lutz Scheideler

1 November 2013 in Acta Biomaterialia
Verified
Journal Article
Closed access
LSLutz Scheideler
Lutz Scheideler
CFC. Füger
C. Füger
CSC. Schille
C. Schille
FRF. Rupp
F. Rupp
HWH.-P. Wendel
H.-P. Wendel
JGJ. Geis-Gerstorfer
J. Geis-Gerstorfer