Liqin Yan

Dr. Liqin Yan

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2025 in Journal of Power Sources
Verified
Journal Article
Closed access
YZYunpeng Zhu
Yunpeng Zhu
LYLiqin Yan
Liqin Yan
SHSongyi Han
Songyi Han
MGMeirong Gu
Meirong Gu
SMSen Ma
Sen Ma
QLQingbo Li
Qingbo Li

28 October 2024 in Batteries
Verified
Journal Article
Open access
PDF file
JCJun Chen
Jun Chen
YLYan Liu
Yan Liu
JYJun Yong
Jun Yong
CYCheng Yang
Cheng Yang
LYLiqin Yan
Liqin Yan
YZYanping Zheng
Yanping Zheng
The accurate estimation of the State of Health (SOH) of lithium-ion batteries is essential for ensuring their safe and reliable operation, as direct measurement is not feasible. This paper presents a novel SOH estimation method that integrates Particle Swarm Optimization (PSO) with an Extreme Learning Machine (ELM) to improve prediction accuracy. Health Indicators (HIs) are first extracted from the battery’s charging curve, and correlation analysis is conducted on seven indirect HIs using Pearson and Spearman coefficients. To reduce dimensionality and eliminate redundancy, Principal Component Analysis (PCA) is applied, with the principal component contributing over 94% used as a fusion HI to represent battery capacity degradation. PSO is then employed to optimize the weights (ε) between the input and hidden layers, as well as the hidden layer bias (u) in the ELM, treating these parameters as particles in the PSO framework. This optimization enhances the ELM’s performance, addressing instability issues in the standard algorithm. The proposed PSO-ELM model demonstrates superior accuracy in SOH prediction compared with ELM and other methods. Experimental results show that the mean absolute error (MAE) is 0.0034, the mean absolute percentage error (MAPE) is 0.467%, and the root mean square error (RMSE) is 0.0043, providing a valuable reference for battery safety and reliability assessments.

1 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
YLYan Liu
Yan Liu
JCJun Chen
Jun Chen
JYJun Yong
Jun Yong
CYCheng Yang
Cheng Yang
LYLiqin Yan
Liqin Yan
YZYanping Zheng
Yanping Zheng
To address the limitations in the prediction accuracy of the remaining useful life (RUL) of lithium-ion batteries, stemming from model accuracy, particle degradation, and insufficient diversity in the particle filter (PF) algorithm, this paper proposes a battery RUL prediction method utilizing a randomly perturbed unscented particle filter (RP-UPF) algorithm, based on the constructed battery capacity degradation model. The method utilizes evaluation metrics adjusted R-squared (Radj2) and the Akaike Information Criterion (AIC) to select the battery capacity decline model C5 with a higher goodness of fit. The initial values for constructing the C5 model are obtained using the relevance vector machine (RVM) and nonlinear least squares methods. Based on the constructed battery capacity decline model C5, the RP-UPF algorithm is employed to estimate the posterior parameters and iteratively approach the true battery capacity decline curve, thereby predicting the battery’s RUL. The research results indicate that, using battery B0005 as an example and starting the prediction from the 50th cycle, the RUL prediction results obtained with the RP-UPF algorithm demonstrate reductions in absolute error, relative error, and probability density function (PDF) width of 2%, 2.71%, and 10%, respectively, compared to the PF algorithm. Similar conclusions were drawn for batteries B0006 and B0018. Under the constructed battery capacity degradation model C5, the RP-UPF algorithm shows higher prediction accuracy for battery RUL and a narrower PDF range compared to the PF algorithm. This approach effectively addresses the issue of particle weight degradation in the PF algorithm, providing a more valuable reference for battery RUL prediction.

19 October 2023 in Journal of Power Sources
Verified
Journal Article
Closed access
YZYunpeng Zhu
Yunpeng Zhu
JSJinhua Song
Jinhua Song
LYLiqin Yan
Liqin Yan
XGXiangfei Guo
Xiangfei Guo
JCJian Chen
Jian Chen
YHYajun Huang
Yajun Huang

13 November 2026 in Electronics
Verified
Journal Article
Open access
PDF file
XLXiaobing Lao
Xiaobing Lao
ZJZhaohui Jin
Zhaohui Jin
JXJingying Xie
Jingying Xie
LYLiqin Yan
Liqin Yan
Cheng WangCheng Wang
Cheng Wang
Hui ZhaoHui Zhao
Hui Zhao
Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.