Felix Zibold

Felix Zibold

Auto-generated profile, based on publicly available information

Felix Zibold

From the University Institute of Diagnostic and Interventional Neuroradiology (J.K., J.G., P.J. Mosimann, F.Z., E.P., T.D., P. Mordasini)

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JKJohannes Kaesmacher
Johannes Kaesmacher
JGJ. Gralla
J. Gralla
PMPascal J. Mosimann
Pascal J. Mosimann
FZF. Zibold
F. Zibold
Mirjam R HeldnerMirjam R Heldner
Mirjam R Heldner
PMP. Mordasini
P. Mordasini
BACKGROUND AND PURPOSE: In 5%–10% of patients with acute ischemic stroke with an intention to treat with mechanical thrombectomy, no reperfusion can be achieved (Thrombolysis in Cerebral Infarction score = 0/1). Purpose of this analysis was a systematic assessment of underlying reasons for reperfusion failures. MATERIALS AND METHODS: An intention-to-treat single-center cohort (n = 592) was re-evaluated for all patients in whom no reperfusion could be achieved (n = 63). Baseline characteristics of patients were compared between patients with and without reperfusion failures. After qualitative review of all cases with reperfusion failures, a classification system was proposed and relative frequencies were reported. In a second step, occurrence of delayed recanalization at 24 hours after reperfusion failure and dependency on IV-tPA were evaluated. RESULTS: In 63/592 patients with an intention to perform stent-retriever thrombectomy, no reperfusion was achieved (TICI 0/1, 10.6%, 95% CI, 8.2%–13.1%). Older patients (adjusted OR per yr = 1.03; 95% CI, 1.01–1.05) and patients with M2 occlusion (adjusted OR = 3.36; 95% CI, 1.82–6.21) were at higher risk for reperfusion failure. In most cases, no reperfusion was a consequence of technical difficulties (56/63, 88.9%). In one-third of these cases, reperfusion failures were due to the inability to reach the target occlusion (20/63, 31.7%), while “stent-retriever failure” occurred in 39.7% (25/63) of patients. Delayed recanalization was very rare (18.2%), without dependence on IV-tPA pretreatment status. CONCLUSIONS: Reasons for reperfusion failure in stent-retriever thrombectomy are heterogeneous. The failure to establish intracranial or cervical access is almost as common as stent-retriever failure after establishing intracranial access. Systematic reporting standards of reasons may help to further estimate relative frequencies and thereby guide priorities for technical development and scientific effort.

17 August 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
EPEike Immo Piechowiak
Eike Immo Piechowiak
FZF. Zibold
F. Zibold
TDT. Dobrocky
T. Dobrocky
PMPascal J. Mosimann
Pascal J. Mosimann
DBD. Bervini
D. Bervini
PMP. Mordasini
P. Mordasini
BACKGROUND AND PURPOSE: Combined transarterial balloon-assisted endovascular embolization with double-lumen balloon microcatheters and concomitant transvenous balloon protection was described as a promising treatment technique for dural arteriovenous fistulae of the transverse and sigmoid sinus. The purpose of this study was to evaluate the technical efficacy and safety of this combined treatment technique. MATERIALS AND METHODS: Nine consecutive patients presenting with dural arteriovenous fistulas of the transverse and sigmoid sinuses underwent combined transarterial and transvenous balloon-assisted endovascular embolization. Prospectively collected data were reviewed to assess the technical success rate, complication rate, and clinical outcome. RESULTS: Six patients presented with clinically symptomatic Borden type I, and 3 patients, with Borden type II dural arteriovenous fistulas of the transverse and sigmoid sinuses (3 men, 6 women; mean age, 50.4 years). Transarterial embolization was performed with a double-lumen balloon with Onyx and concomitant transvenous sinus protection with a dedicated venous remodeling balloon. Complete angiographic occlusion at the latest follow-up (mean, 4.8 months) was achieved in 6 patients, and near-complete occlusion, in 2 patients. Clinical cure or remission of symptoms was obtained in 6 and 2 patients, respectively. One patient with a residual fistula underwent further treatment in which the dural arteriovenous fistula was cured by sinus occlusion. Complete occlusion of the dural arteriovenous fistula was visible on the follow-up angiography after final treatment in 8 patients. One patient refused follow-up angiography but was free of symptoms. There were no immediate or delayed postinterventional complications. CONCLUSIONS: Transarterial balloon-assisted embolization of dural arteriovenous fistulas of the transverse and sigmoid sinuses with combined transvenous balloon protection is safe and offers a high rate of complete dural arteriovenous fistula occlusion and remission of clinical symptoms.

13 November 2015 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
FZFelix Zibold
Felix Zibold
JKJustus F Kleine
Justus F Kleine
CZClaus Zimmer
Claus Zimmer
HPHolger Poppert
Holger Poppert
TBTobias Boeckh-Behrens
Tobias Boeckh-Behrens
Background and purpose Coincidental aneurysms in the target vessels of stroke patients with large vessel occlusions (LVO) may pose risks during endovascular mechanical thrombectomy (MTE), but there are almost no data on this subject. Motivated by an incident of rupture of a hidden aneurysm induced by withdrawal of a stent retriever during a MTE procedure, this study examines the prevalence of aneurysms, associated complications, and implications for treatment strategies in patients with LVO stroke. Methods A single-center retrospective analysis of angiographic and CT/MRI images and case records of 300 consecutive patients with LVO stroke treated with MTE was performed. Results Aneurysms related to target vessels were detected in 11/300 patients, in 10/11 in the anterior circulation. In 9/11 patients the aneurysms were unknown prior to the stroke. The observed prevalence was >2-fold higher than expected for a healthy reference population. There was one complication (aneurysm rupture), as described above. In two subsequent patients with known aneurysms, MTE was conducted mainly with aspiration techniques which failed, contributing to a low recanalization rate in patients with aneurysm (45%). Conclusions The prevalence of aneurysms is relatively high in patients with LVO stroke, particularly in older, female, hypertensive patients, presumably reflecting overlapping risk factors. MTE should not be withheld from patients with LVO stroke with aneurysms, but particularly cautious approaches may be warranted. Further research in larger samples is required to obtain precise data on the prevalence and associated complication rates in MTE procedures. This is necessary to estimate the true risk and to tailor endovascular strategies in these patients.

1 September 2017 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
FZFelix Zibold
Felix Zibold
PMPasquale Mordasini
Pasquale Mordasini
PMPascal Mosimann
Pascal Mosimann
EPEike Piechowiak
Eike Piechowiak
TDTomas Dobrocky
Tomas Dobrocky
JGJan Gralla
Jan Gralla