Objectives: This study aims to compare the efficacy of the eccentric exercise (EE) and extracorporeal shock wave therapy (ESWT) on chronic midportion Achilles tendinopathy and evaluate the efficacy of these treatment modalities on tendon thickness, vascularity, and elasticity. Patients and methods: In this randomized controlled trial, a total of 63 patients (40 females, 23 males; mean age: 37.3±12.2; range, 18 to 55 years) with chronic midportion Achilles tendinopathy were enrolled between April 2017 and December 2019. The patients were allocated randomly to two groups: the first group was treated with EE every day for three months with the Alfredson protocol, and the second group received four sessions of ESWT at weekly intervals. The study was terminated at the end of three months. Visual Analog Scales (VAS), Victorian Institute of Sports Assessment-Achilles (VISA-A) questionnaires, and ultrasonography measurements were assessed before and after treatment. Patient pain was evaluated at the two-year follow-up. Results: At the three-month follow up, VAS scores decreased, and VISA-A scores increased in both groups (p<0.001). At the two-year-follow-up, VAS scores significantly decreased in the EE group (p<0.001), but the difference was statistically insignificant in the ESWT group (p=0.095). Tendon thickness and stiffness increased in the EE group (p=0.003 and p=0.03, respectively) while the difference was statistically insignificant in the ESWT group after treatment (p=0.173 and p=0.702, respectively). Conclusion: Eccentric exercise and ESWT are efficient in the short term, whereas EE is efficient on tendon pain in the long term. While EE increases tendon thickness and stiffness, ESWT has no effect on these measures.
17 August 2022 in Journal of NeuroInterventional Surgery
Background: High-frequency optical coherence tomography (HF-OCT) is an intravascular imaging method that allows for volumetric imaging of flow diverters in vivo.Objective: To examine the hypothesis that a threshold for both volume and area of communicating malapposition can be predictive of early aneurysm occlusion.Methods: Fifty-two rabbits underwent elastase aneurysm formation, followed by treatment with a flow diverter. At the time of implant, HF-OCT was acquired to study the rate and degree of communicating malapposition. Treated aneurysms were allowed to heal for either 90 or 180 days and euthanized following catheter angiography. Healing was dichotomized into aneurysm remnant or neck remnant/complete occlusion. Communicating malapposition was measured by HF-OCT using a semi-automatic algorithm able to detect any points where the flow diverter was more than 50 µm from the vessel wall. This was then summed across image slices to either a volume or area. Finally, a subsampled population was used to train a statistical classifier for the larger dataset.Results: No difference in occlusion rate was found between device type or follow-up time (p=0.28 and p=0.67, respectively). Both volume and area of malapposition were significantly lower in aneurysms with a good outcome (p<0.001, both). From the statistical model, a volume of less than 0.56 mm3or a normalized area less than 0.69 as quantified by HF-OCT was predictive of occlusion (p<0.001, each).Conclusions: HF-OCT allows for measurements of both volume and area of malapposition and, from these measurements, an accurate prediction for early aneurysm occlusion can be made.
17 June 2023 in Journal of NeuroInterventional Surgery
Background: Flow diverters carry the risk of thromboembolic complications (TEC). We tested a coating with covalently bound heparin that activates antithrombin to address TEC by locally downregulating the coagulation cascade. We hypothesized that the neuroimaging evidence of TEC would be reduced by the coating.Methods: 16 dogs were implanted with overlapping flow diverters in the basilar artery, separated into two groups: heparin-coated (n=9) and uncoated (n=7). Following implantation, high-frequency optical coherence tomography (HF-OCT) was acquired to quantify acute thrombus (AT) formation on the flow diverters. MRI was performed postoperatively and repeated at 1, 2, 3, 4, and 8 weeks, consisting of T1-weighted imaging, time-0f-flight (ToF), diffusion weighted imaging (DWI), susceptibility weighted imaging (SWI), and fluid attenuated inversion recovery (FLAIR) sequences. Neurological examinations were performed throughout the 8-week duration of the study.Results: The mean AT volume on coated devices was lower than uncoated (0.014 vs 0.018 mm3); however, this was not significant (P=0.3). The mean number of foci of magnetic susceptibility artifacts (MSAs) on SWI was significantly different between the uncoated and coated groups at the 1-week follow-up (P<0.02), and remained statistically different throughout the duration of the study. The AT volume showed a direct linear correlation with the MSA count and 80% of the variance in the MSA could be explained by the AT volume (P<0.001). Pathological analysis showed evidence of ischemic injury at locations of MSA.Conclusions: Heparin-coated flow diverters significantly reduced the number of new MSAs after 1 week follow-up, showing the potential to reduce TEC.
12 September 2020 in Journal of Ultrasound in Medicine