BARIŞ OĞUZ GÜRSES

Dr. BARIŞ OĞUZ GÜRSES

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Composites Part B: Engineering
Verified
Journal Article
Closed access
OYOzgun Cem Yılmaz
Ozgun Cem Yılmaz
ISIbrahim Sen
Ibrahim Sen
BGBARIŞ OĞUZ GÜRSES
BARIŞ OĞUZ GÜRSES
OOOkan Ozdemir
Okan Ozdemir
LCLevent Cetin
Levent Cetin
EAEmine Altinkaya
Emine Altinkaya

1 December 2021 in Meandros Medical and Dental Journal
Verified
Journal Article
Closed access
SSSercan Sabancı
Sercan Sabancı
EŞElif Şener
Elif Şener
RTRukiye Irmak Turhal
Rukiye Irmak Turhal
BGBARIŞ OĞUZ GÜRSES
BARIŞ OĞUZ GÜRSES
FGFigen GOVSA
Figen GOVSA
PGPelin Güneri
Pelin Güneri

16 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Cem PeskersoyCem Peskersoy
Cem Peskersoy
MSMert Sener
Mert Sener
BGBARIŞ OĞUZ GÜRSES
BARIŞ OĞUZ GÜRSES
EEEda Erbil
Eda Erbil
MTMurat Türkün
Murat Türkün
The purpose of this study is to evaluate the influence of the matrix system on proximal contact tightness (PCT) of posterior composite resin restorations. Standardized class II cavities on 180 first lower molar dentiform model teeth (Frasaco GmbH, Tettnang, Germany) were prepared. Three groups were formed considering the matrix system: Group-IM: Ivory matrix (Hahnenkratt GmbH, Königsbach-Stein, Germany), Group-OM: Omni matrix (Ultradent, South Jordan, UT, USA), and Group-PM: Palodent V3 sectional matrix (Dentsply, Charlotte, NC, USA). Teeth were restored with resin composite mounted in a manikin head to simulate the clinical environment. Proximal contact tightness (PCT) was measured using a custom-made portable dental pressure meter (PDPM), and the validation of the PCT results was performed with a histogram analysis acquired from bite-wing radiography. All data were statistically analyzed by ANOVA and t-test in SPSS software (v.27.0) (p < 0.05). PM group showed statistically tighter contacts on both mesial (PCTm: 228.28 ± 59.17 N) and distal surfaces (PCTd: 254.91 ± 65.69 N) (p > 0.05). Mesial contacts were found to be significantly tighter than distal contacts among all (p < 0.05). According to the histogram results, only in the PM group, the difference between the mesial and distal areas is significant (p < 0.05). Histogram results confirmed that the tightest contact values were achieved in the PM group, followed by the OM and IM groups, respectively (p < 0.05). The use of sectional matrix systems and separation rings is more effective in creating tighter contact than conventional matrix systems. The use of anatomical wedges will help to create a more natural approximal contour and narrow contact area.

1 March 2022 in Journal of Polytechnic
Verified
Journal Article
Closed access
PDF file
MSMert Sener
Mert Sener
FAF.Mertkan Arslan
F.Mertkan Arslan
BGBARIŞ OĞUZ GÜRSES
BARIŞ OĞUZ GÜRSES
GGGökhan Gürlek
Gökhan Gürlek
Electronic driver circuits are used for the driving of ultrasonic transducer systems. Due to the high frequency switching, thermal management is the main problem that has a significant effect on the reliability of the driver. Different applications are being studied to solve such overheating problems. In this study, the designed thermoelectric self-cooling system dissipates the excess heat generated in the push-pull drive circuit and improves system performance. Thermoelectric self-cooling (TSC) is a new thermoelectric application which provide the cooling of any heat-generating device without electricity consumption. This paper presents the experimental analysis of a TSC system. An experimental setup is designed on a 275W push-pull ultrasonic driver circuit. In this study, it has been shown how the performance of the thermoelectric system changes with the use of cold extender of different thicknesses. 5 and 10 mm thickness cold extenders have had a positive effect on the cooling performance of both the hot and cold surfaces of the self-cooling system. However, when the thickness of the cold extender is increased beyond the threshold, the heat capacity of the cold extender has prevented the temperature between the cold and hot surfaces to reach critical temperature differences which enables the fan to operate.

28 January 2024 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
MDM. Melih Doğan
M. Melih Doğan
MKM. Serhan Küçüka
M. Serhan Küçüka
BGBARIŞ OĞUZ GÜRSES
BARIŞ OĞUZ GÜRSES

1 January 2025
Verified
Conference Paper
Open access
PDF file
NGNida Gülsevin
Nida Gülsevin
GGGökhan Gürlek
Gökhan Gürlek
BGBARIŞ OĞUZ GÜRSES
BARIŞ OĞUZ GÜRSES
BBBekir Boyacı
Bekir Boyacı
TUTuğçe Uysal
Tuğçe Uysal
GBGürses B.
Gürses B.
In recent years, the increase in legal regulations concerning personal protection has been accompanied by a significant growth trend in the protective clothing industry. The primary purpose of protective clothing is to provide a barrier against biological, chemical, physical, and mechanical hazards in the relevant field. However, to support the wearer's performance, these garments are also expected to maintain the body's thermal balance and manage thermal stress, depending on environmental conditions. Research in this area has shown that protective clothing used in various fields often exhibits insufficient heat and moisture transfer ability, indicating deficiencies that need to be addressed based on their intended use. Particularly in products where textile material properties are prominent and effective-such as firefighter suits, CBRN suits, and surgical gowns-there is significant potential for development and application, making them attractive for innovative studies. Within the scope of this study, the active and passive cooling systems engineered to enhance heat transfer and decrease thermal stress will be given in detail.