Dongchu Chen

Dongchu Chen


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
QHQuanguo He
Quanguo He
JLJun Liu
Jun Liu
XLXiaopeng Liu
Xiaopeng Liu
Guangli LiGuangli Li
Guangli Li
DCDongchu Chen
Dongchu Chen
JLJing Liang
Jing Liang
Amine-modified magnetite (NH2–Fe3O4)/reduced graphene oxide nanocomposite modified glassy carbon electrodes (NH2–Fe3O4/RGO/GCEs) were developed for the sensitive detection of dopamine (DA). The NH2-Fe3O4/RGO/GCEs were fabricated using a drop-casting method followed by an electrochemical reduction process. The surface morphologies, microstructure and chemical compositions of the NH2–Fe3O4 nanoparticles (NPs), reduced graphene oxide (RGO) sheets and NH2–Fe3O4/RGO nanocomposites were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-Ray diffraction (XRD) and Fourier-transform infrared (FTIR) spectroscopy. The electrochemical behaviors of DA on the bare and modified GCEs were investigated in phosphate buffer solution (PBS) by cyclic voltammetry (CV). Compared with bare electrode and RGO/GCE, the oxidation peak current (ipa) on the NH2–Fe3O4/RGO/GCE increase significantly, owing to the synergistic effect between NH2–Fe3O4 NPs and RGO sheets. The oxidation peak currents (ipa) increase linearly with the concentrations of DA in the range of 1 × 10−8 mol/L – 1 × 10−7 mol/L, 1 × 10−7 mol/L – 1 × 10−6 mol/L and 1 × 10−6 mol/L – 1 × 10−5 mol/L. The detection limit is (4.0 ± 0.36) ×10−9 mol/L (S/N = 3). Moreover, the response peak currents of DA were hardly interfered with the coexistence of ascorbic acid (AA) and uric acid (UA). The proposed NH2–Fe3O4/RGO/GCE is successfully applied to the detection of dopamine hydrochloride injections with satisfactory results. Together with low cost, facile operation, good selectivity and high sensitivity, the NH2–Fe3O4/RGO/GCEs have tremendous prospects for the detection of DA in various real samples.

13 March 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
QHQuanguo He
Quanguo He
YTyaling Tian
yaling Tian
WYWu Yiyong
Wu Yiyong
JLJun Liu
Jun Liu
Guangli LiGuangli Li
Guangli Li
DCDongchu Chen
Dongchu Chen
4-nitrophenol (4-NP) is a hazardous waste and a priority toxic pollutant identified by US Environmental Protection Agency (EPA). Hence, in this paper, a voltammetric sensor was proposed for the direct and sensitive detection of 4-nitrophenol (4-NP) at nanomolar level in complex matrices by using graphene and acetylene black paste hybridized electrode (GR/ABPE). Under optimal conditions, the calibration curve demonstrates a linear relationship for 4-NP in the range from 20 nM to 8.0 μM and 8.0 μM to 0.1 mM separately with the detection limit of 8.0 nM. In addition to it, the performance of the GR/ABPE in practical applications was evaluated by detecting 4-NP in various water samples, and satisfactory recoveries were realized. Therefore, GR/ABPE may have a great potential application for facile and sensitive detection of 4-NP in complex matrices at nanomolar level.

26 November 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
PJPengfei Jiang
Pengfei Jiang
YWYulin Wang
Yulin Wang
LZLan Zhao
Lan Zhao
CJChenyang Ji
Chenyang Ji
DCDongchu Chen
Dongchu Chen
Libo NieLibo Nie
Libo Nie
Due to their unique properties, such as good biocompatibility, excellent conductivity, effective catalysis, high density, and high surface-to-volume ratio, gold nanoparticles (AuNPs) are widely used in the field of bioassay. Mainly, AuNPs used in optical biosensors have been described in some reviews. In this review, we highlight recent advances in AuNP-based non-optical bioassays, including piezoelectric biosensor, electrochemical biosensor, and inductively coupled plasma mass spectrometry (ICP-MS) bio-detection. Some representative examples are presented to illustrate the effect of AuNPs in non-optical bioassay and the mechanisms of AuNPs in improving detection performances are described. Finally, the review summarizes the future prospects of AuNPs in non-optical biosensors.

18 January 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
QHQuanguo He
Quanguo He
WYWu Yiyong
Wu Yiyong
YTyaling Tian
yaling Tian
Guangli LiGuangli Li
Guangli Li
JLJun Liu
Jun Liu
DCDongchu Chen
Dongchu Chen
A new electrochemical sensor for nanomolar rutin detection based on amine-functionalized Fe3O4 nanoparticles and electrochemically reduced graphene oxide nanocomposite modified glassy carbon electrode (NH2-Fe3O4 NPs-ErGO/GCE) was fabricated through a simple method, and the X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscope (SEM), transmission electron microscope (TEM), vibrating sample magnetometer (VSM) and electrochemical technique were used to characterize the modified electrode. The electrochemical behavior of rutin on the Fe3O4 NPs-ErGO/GCE was studied in detail. The electrochemical response of rutin at this modified electrode was remarkably higher than that of the bare GCE or other modified GCE (GO/GCE, Fe3O4 NPs-GO/GCE, and ErGO/GCE). Under the optimum determination conditions, Fe3O4 NPs-ErGO/GCE provided rutin with a broader detection range of 6.0 nM–0.1 µM; 0.1–8.0 µM and 8.0–80 µM, a minimum detectable concentration of 4.0 nM was obtained after 210 s accumulation. This novel method was applied in determination of rutin in pharmaceutical tablets and urine samples with satisfactory results.

8 May 2019 in Biomolecules
Verified
Journal Article
Open access
PDF file
QHQuanguo He
Quanguo He
YTyaling Tian
yaling Tian
WYWu Yiyong
Wu Yiyong
JLJun Liu
Jun Liu
Guangli LiGuangli Li
Guangli Li
DCDongchu Chen
Dongchu Chen
In this paper, a nanocomposite of cuprous oxide and electrochemically reduced graphene oxide (Cu2O–ERGO) was prepared by a simple and low-cost method; hereby, a new method for the electrochemical determination of tryptophan (Trp) by this composite modified glassy carbon electrode (GCE) is proposed. The prepared materials and modified electrodes were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and cyclic voltammetry (CV). The results showed that Cu2O–ERGO/GCE had good electrocatalytic activity for Trp. The effects of supporting electrolyte, scanning rate, accumulation potential, and accumulation time on the determination of Trp were studied. Under the optimum experimental conditions, Trp was quantitatively analyzed by square-wave voltammetry (SWV). The oxidation peak current of Trp had a good linear relationship with its concentration in the range of 0.02–20 μM, and the detection limit was 0.01 μM (S/N = 3). In addition, the modified electrode has high sensitivity, good repeatability, and long-term stability. Finally, the proposed method has been successfully applied in the determination of Trp concentration in practical samples.

7 February 2021 in Science China Materials
Verified
Journal Article
Closed access
PDF file
CDChongxiong Duan
Chongxiong Duan
YYYi Yu
Yi Yu
JLJingjing Li
Jingjing Li
LLLibo Li
Libo Li
BHBichun Huang
Bichun Huang
HXHongxia Xi
Hongxia Xi