Temperature, salinity, and pressure (TSP) are essential parameters for the ocean. Optical fiber sensors (OFSs) have rapidly come into focus as an ocean detection technology in recent years due to their advantages of electromagnetic interference, light weight, low cost, and no waterproof requirement. In this paper, the most recently developed TSP sensors for single parameter and multi-parameter TSP sensing and measurement based on different OFSs are reviewed. In addition, from the practical point of view, encapsulation methods that protect fibers and maintain the normal operation of OFSs in seawater, and the response time of the OFS, are addressed. Finally, we discuss the prospects and challenges of OFSs used in marine environments and provide some clues for future work.
Simultaneous measurement of pressure and temperature in seawater is realized based on the polydimethylsiloxane (PDMS) sealed microfiber Mach-Zehnder interferometer (MZI). Benefitting from the high thermal-optic coefficient and large elasticity of PDMS, high sensitivity and robust sensing structure can be obtained. In theoretical modeling, significant enhanced pressure response in fiber is observed clearly, and pressure and temperature sensitivities are calculated theoretically. In experiment, PDMS sealed MZI is fabricated by a two-step sealing method. Using the sealed MZI, sensitivity of 13.31 nm/MPa for pressure sensing and 7.41 nm/C for temperature sensing are demonstrated, respectively, which are about one order higher than the bare fiber MZIs (without PDMS sealing). To verify the accuracy of the sensor, several tests under arbitrarily pressure and temperature are performed with average errors of 4.38% and 1.44%, respectively. In addition, effects of the encapsulation on avoiding cross-sensitivity with salinity, PDMS thickness on pressure sensitivity, response time, repeatability, time stability, and polarization of the sensor are also evaluated by experiment. Sensors demonstrated here show advantages of low cost, simple fabrication, robust and compact structure, high-pressure resistance, high sensitivity, good repeatability and long-term stability.
Ocean internal-wave phenomena occur with the variation in seawater vertical temperature, and most internal-wave detections are dependent on the measurement of seawater vertical temperature. A seawater temperature sensor based on a microfiber knot resonator (MKR) is designed theoretically and demonstrated experimentally in this paper. Especially, the dependences of sensing sensitivity on fiber diameter and probing wavelength are studied. Calculated results show that sensing sensitivity increases with the increasing microfiber diameter with the range of 2.30–3.91 μm and increases with the increasing probing wavelength, which reach good agreement with results obtained by experiments. By choosing the appropriate parameters, the maximum sensitivity measured can reach to be 22.81 pm/°C. The seawater temperature sensor demonstrated here shows advantages of small size, high sensitivity, easy fabrication, and easy integration with fiber systems, which may offer a new optical method to detect temperature of seawater or ocean internal-wave phenomenon and offer valuable reference for assembling micro sensors used for other parameters related to seawater, such as salinity, refractive index, concentration of NO3− and so on.
A simple, high-sensitivity, and low-cost optical sensor for the measurement of temperature and salinity in seawater is demonstrated based on a microfiber directional coupler. The shifts of sensing dips are highly sensitive to the change of salinity and temperature in seawater with highest sensitivities at 930 pm/% and -160 pm/°C for coupler assembled by 3.79and 2.20-μm-diameter fibers. The temperature sensitivity can be further improved to -1130 pm/°C for smaller fibers with diameters of 3.50 and 1.35 μm. To keep the stable structure in liquid, a methodology of coating using ethyl cellulose ethoce film is proposed. By ethyl cellulose ethoce solvent coating on the coupling area, the coupler can be operated stably in seawater. The sensor demonstrated here is easy to construct, is low cost, is high sensitivity, and is compatible with the optical fiber system, which may find applications in developing miniature and multifunction optical sensors used in seawater and other liquid surroundings.
Encapsulation of microfiber Mach-Zehnder interferometer (MMZI) sensor for temperature and salinity sensing in seawater is developed. It includes a C-shape metal tube with a slit on the bottom and polymer adhesive with large elasticity modulus, by which a more robust sensor with relatively fast response can be obtained. To evaluate the performance of sensor after encapsulation, effects of different polymer adhesives on tension withstanding, temperature and salinity sensitivities are evaluated, and dependence of response time on shape of metal tube is investigated. Results show that sensitivities of the sensor in temperature and salinity sensing can reach to be about −1.77 nm/°C and 1.18 nm/ ‰, and response times are about 219.0 ms and 12.5 ms, respectively. By comparing temperatures and salinities measured by sensor with those measured by commercial device, accuracy of the sensor after encapsulation is proved. In addition, cross-sensitivities of strain/pressure and short/long-term stability after encapsulation are also evaluated. Finally, based on the basic structure, further improvements are attempted, such as double encapsulation with stainless steel mesh and complex encapsulation with two kinds of polymer. Encapsulations of MMZI demonstrated here show advantages of low cost, improved robustness, relatively fast response, long-term stability and easy expandability, which will not only afford a critical support for optical sensors operated in the ocean, but also offer some useful references for microfiber sensors used in other sensing applications.
An all-fiber Mach–Zehnder interferometer (MZI) for two quasi-continuous points’ temperature sensing in seawater is proposed. Based on the beam propagation theory, transmission spectrum is designed to present two sets of clear and independent interferences. Following this design, MZI is fabricated and two points’ temperature sensing in seawater are demonstrated with sensitivities of 42.69pm/°C and 39.17pm/°C, respectively. By further optimization, sensitivity of 80.91pm/°C can be obtained, which is 3-10 times higher than fiber Bragg gratings and microfiber resonator, and higher than almost all similar MZI based temperature sensors. In addition, factors affecting sensitivities are also discussed and verified in experiment. The two points’ temperature sensing demonstrated here show advantages of simple and compact construction, robust structure, easy fabrication, high sensitivity, immunity to salinity and tunable distance of 1-20 centimeters between two points, which may provide references for macroscopic oceanic research and other sensing applications based on MZIs.