Temperature, salinity, and pressure (TSP) are essential parameters for the ocean. Optical fiber sensors (OFSs) have rapidly come into focus as an ocean detection technology in recent years due to their advantages of electromagnetic interference, light weight, low cost, and no waterproof requirement. In this paper, the most recently developed TSP sensors for single parameter and multi-parameter TSP sensing and measurement based on different OFSs are reviewed. In addition, from the practical point of view, encapsulation methods that protect fibers and maintain the normal operation of OFSs in seawater, and the response time of the OFS, are addressed. Finally, we discuss the prospects and challenges of OFSs used in marine environments and provide some clues for future work.
Simultaneous measurement of pressure and temperature in seawater is realized based on the polydimethylsiloxane (PDMS) sealed microfiber Mach-Zehnder interferometer (MZI). Benefitting from the high thermal-optic coefficient and large elasticity of PDMS, high sensitivity and robust sensing structure can be obtained. In theoretical modeling, significant enhanced pressure response in fiber is observed clearly, and pressure and temperature sensitivities are calculated theoretically. In experiment, PDMS sealed MZI is fabricated by a two-step sealing method. Using the sealed MZI, sensitivity of 13.31 nm/MPa for pressure sensing and 7.41 nm/C for temperature sensing are demonstrated, respectively, which are about one order higher than the bare fiber MZIs (without PDMS sealing). To verify the accuracy of the sensor, several tests under arbitrarily pressure and temperature are performed with average errors of 4.38% and 1.44%, respectively. In addition, effects of the encapsulation on avoiding cross-sensitivity with salinity, PDMS thickness on pressure sensitivity, response time, repeatability, time stability, and polarization of the sensor are also evaluated by experiment. Sensors demonstrated here show advantages of low cost, simple fabrication, robust and compact structure, high-pressure resistance, high sensitivity, good repeatability and long-term stability.
Ocean internal-wave phenomena occur with the variation in seawater vertical temperature, and most internal-wave detections are dependent on the measurement of seawater vertical temperature. A seawater temperature sensor based on a microfiber knot resonator (MKR) is designed theoretically and demonstrated experimentally in this paper. Especially, the dependences of sensing sensitivity on fiber diameter and probing wavelength are studied. Calculated results show that sensing sensitivity increases with the increasing microfiber diameter with the range of 2.30–3.91 μm and increases with the increasing probing wavelength, which reach good agreement with results obtained by experiments. By choosing the appropriate parameters, the maximum sensitivity measured can reach to be 22.81 pm/°C. The seawater temperature sensor demonstrated here shows advantages of small size, high sensitivity, easy fabrication, and easy integration with fiber systems, which may offer a new optical method to detect temperature of seawater or ocean internal-wave phenomenon and offer valuable reference for assembling micro sensors used for other parameters related to seawater, such as salinity, refractive index, concentration of NO3− and so on.
The salinity and temperature of seawater are important parameters in oceanography. Based on the directional coupler assembled by polyimide-coated micro/nanofibers, optical sensors with high sensitivity for simultaneous salinity and temperature sensing in seawater are proposed. Dependences of sensitivities on wavelength, salinity, and temperature are investigated theoretically, with which performances of such sensor under general sea conditions can be evaluated. Results show that salinity and temperature sensitivities can reach levels of nm/‰ and nm/°C, which are much higher than those of fiber Bragg gratings, knot resonators, and photonic crystal fibers. Other considerations for system design such as the length of the coupling area, the diameter difference between two fibers, and the thickness of polyimide coatings are also discussed. Sensors proposed here suggest a simple approach to realize high-sensitivity micro/nanofiber optical sensing of salinity and temperature in seawater simultaneously and may find applications in developing miniature sensors used in seawater.
In this paper, an ultrahigh sensitivity sensing in aqueous solution for microfiber modal interferometer (MMI) is realized. The group refractive index (RI) difference between HE11 and HE12 mode will come down to 0 at a certain wavelength, resulting in ultrahigh sensitivity near this wavelength. MMI with different diameters have their individual ultrasensitive wavelength band, which indicates the broad range of optional probing wavelength and more liberal diameter condition on fiber fabrication. In the experimentation, infrared absorption band in water around 1360-1600nm is easy to keep away by adjusting the microfiber diameter. As a result, an ultrahigh sensitivity of 14.95 pm/ppm is realized for sodium nitrate at 1320nm, whose equivalent sensitivity is about 1.26 × 105-nm/RIU for RI, which is much higher than most of the existing naked sensors with magnitude of 102-104nm/RIU.