An increasing number of people want to reduce their environmental footprint by using harvested rainwater as a source for drinking water. Moreover, implementing rainwater harvesting (RWH) enables protection against damage caused by increasing precipitation frequency and intensity, which is predicted for Western Europe. In this study, literature data on rainwater quality were reviewed, and based on Dutch climatological data the usable quantity of rainwater in the Netherlands was calculated. For two specific cases, (1) a densely populated city district and (2) a single house in a rural area, the total costs of ownership (TCO) for decentralized drinking water supply from harvested rainwater was calculated, and a life cycle assessment (LCA) was made. For the single house it was found that costs were very high (€60–€110/m3), and the environmental impact would not decrease. For the city district, costs would be comparable to the present costs of centralized drinking water production and supply, but the environmental benefit is negligible (≤1‰). Furthermore, it was found that the amount of rainwater that can be harvested in the city district only covers about 50% of the demand. It was concluded that the application of rainwater harvesting for drinking water production in the Netherlands is not economically feasible.
Nanoparticles, such as metallic ones like Ag, Au and TiO 2 as well as nanoplastics, are applied in or emitted by a wide variety of products or stem from degradation.
The aquatic environment and drinking water production are under increasing pressure from the presence of pharmaceuticals and their transformation products in surface waters. Demographic developments and climate change result in increasing environmental concentrations, deeming abatement measures necessary. Here, we report on an extensive case study around the river Meuse and its tributaries in the south of The Netherlands. For the first time, concentrations in the tributaries were measured and their apportionment to a drinking water intake downstream were calculated and measured. Large variations, depending on the river discharge were observed. At low discharge, total concentrations up to 40 μg/L were detected, with individual pharmaceuticals exceeding thresholds of toxicological concern and ecological water-quality standards. Several abatement options, like reorganization of wastewater treatment plants (WWTPs), and additional treatment of wastewater or drinking water were evaluated. Abatement at all WWTPs would result in a good chemical and ecological status in the rivers as required by the European Union (EU) Water Framework Directive. Considering long implementation periods and high investment costs, we recommend prioritizing additional treatment at the WWTPs with a high contribution to the environment. If drinking water quality is at risk, temporary treatment solutions in drinking water production can be considered. Pilot plant research proved that ultraviolet (UV) oxidation is a suitable solution for drinking water and wastewater treatment, the latter preferably in combination with effluent organic matter removal. In this way >95% of removal of pharmaceuticals and their transformation products can be achieved, both in drinking water and in wastewater. Application of UV/H2O2, preceded by humic acid removal by ion exchange, will cost about €0.23/m3 treated water.
The UV/SO32– process can be applied to convert organic micropollutants (OMP). The reaction is induced by UV photolysis of sulphite (preferably using a medium pressure (MP) UV lamp). Although in general it is assumed that the UV/SO32− process is an advanced reduction process, our results show degradation of OMP under both anoxic and oxic conditions. Several recalcitrant OMP even show higher degradation rates under oxic conditions than under anoxic conditions. This conversion is affected by the presence of dissolved organic carbon (DOC), HCO3− and NO3−, and thus was more effective in drinking water than in Milli-Q water. The reaction rate constants of the oxic UV/SO32− process in general are lower than those of a UV/H2O2 process, but in cases where the use of H2O2 is not preferred, the UV/SO32− process may be an interesting alternative.