Robert Hennings

Dr. Robert Hennings

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
RHRobert Hennings
Robert Hennings
FSFiras Souleiman
Firas Souleiman
MHMartin Heilemann
Martin Heilemann
MHMareike Hennings
Mareike Hennings
AKAlexis Klengel
Alexis Klengel
AAAnnette B. Ahrberg
Annette B. Ahrberg
Background: Inadequate reduction of syndesmotic injuries can result in disabling clinical outcomes. The aim of the study was to compare syndesmosis congruity after fixation by syndesmotic screws (SYS) or a suture button system (SBS) using three-dimensional (3D) computed imaging techniques. Methods: In a retrospective single-center study, patients with unilateral stabilization of an ankle fracture with a syndesmotic injury and post-operative bilateral CT scans were analyzed using a recently established 3D method. The side-to-side differences were compared for tibio-fibular clear space (∆CS), translation angle (∆α), and vertical offset (∆z) among patients stabilized with syndesmotic screws or suture button system. Syndesmotic malreduction was defined for ∆CS > 2 mm and for |∆α| > 5°. ∆CS and ∆α were correlated with two-dimensional (2D) measurements. Results: Eighteen patients stabilized with a syndesmosis screw and 29 stabilized with a suture button system were analyzed. After stabilization, both groups revealed mild diastasis (SYS: mean ∆CS 0.3 mm, SD 1.1 mm vs SBS: mean ∆CS 0.2 mm, SD 1.2 mm, p = 0.710). In addition, both stabilization methods showed slight dorsalization of the fibula (SYS: mean ∆α 0.5°, SD 4.6° vs SBS: mean ∆α 2.1°, SD 3.7°, p = 0.192). Also, restoration of the fibula-to-tibia length ratio also did not differ between the two groups (SYS: mean Δz of 0.5 mm, SD 2.4 mm vs SBS: mean Δz of 0 mm, SD 1.2 mm; p = 0.477). Malreduction according to high ∆α was most common (26% of cases), with equal distribution between the groups (p = 0.234). ∆CS and ∆α showed good correlation with 2D measurements (ρ = 0.567; ρ = 0.671). Conclusion: This in vivo analysis of post-operative 3D models showed no differences in immediate post-operative alignment after syndesmotic screws or suture button system. Special attention should be paid to syndesmotic malreduction in the sagittal orientation of the fibula in relation to the tibia in radiological control of the syndesmotic congruity as well as intra-operatively.

19 August 2022 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
RHRobert Hennings
Robert Hennings
CFCarolin Fuchs
Carolin Fuchs
USUlrich J. Spiegl
Ulrich J. Spiegl
JTJan Theopold
Jan Theopold
FSFiras Souleiman
Firas Souleiman
AAAnnette B. Ahrberg
Annette B. Ahrberg
Purpose: Fibular mobility after suture button stabilization (SBS) of inferior tibiofibular joint (syndesmosis) injuries has been described. This effect is called the “flexible nature of fixation (FNF).” In this study, we aimed to quantify FNF in syndesmotic stabilization. Methods: Postoperative bilateral computed tomography (CT) of ankle fractures with syndesmosis stabilization by SBS or syndesmotic screw (SYS) was retrospectively analyzed. The transverse offset (TO) and vertical offset (VO) were defined by evaluating the drill channels. The reduction outcome was evaluated by the side-to-side difference between the clear space and the anterior tibiofibular distance (antTFD). The calculated anterior tibiofibular distance (cal-antTFD) was calculated by subtracting the TO from the validated antTFD. Subsequently, a reevaluation of the reduction outcomes after SYS or SBS stabilization was performed using cal-antTFD. Results: Sixty patients (44 with SBS and 16 with SYS stabilization) were analyzed. The intra-rater and inter-rater reliabilities for TO and VO were excellent (α > 0.92). SYS stabilization showed lower mean TO (− 0.02 mm; SD 0.14) and VO (0.11 mm; SD, 0.29 mm) than SBS stabilization (TO 1.16 mm, SD 1.4 mm; VO 0.2 mm, SD 0.8 mm; p = 0.001). The rate of malreduction according to cal-antTFD was higher than that of antFTD (p = 0.033). Conclusion: The presented method, which evaluates the position of the tibial to the fibular drill channel, allowed the quantification of the “FNF.” The often described difference in the dynamic stabilization of SBS compared to the rigid stabilization by SYS could be objectified. Considering cal-antTFD illustrates that FNF potentially reduces the rate of malreduction in SBS stabilization.

7 June 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FSFiras Souleiman
Firas Souleiman
MHMartin Heilemann
Martin Heilemann
RHRobert Hennings
Robert Hennings
PHPierre Hepp
Pierre Hepp
Boyko GueorguievBoyko Gueorguiev
Boyko Gueorguiev
DGDominic Gehweiler
Dominic Gehweiler
The aim of this study was to investigate the effect of different loading scenarios and foot positions on the configuration of the distal tibiofibular joint (DTFJ). Fourteen paired human cadaveric lower legs were mounted in a loading frame. Computed tomography scans were obtained in unloaded state (75 N) and single-leg loaded stand (700 N) of each specimen in five foot positions: neutral, 15° external rotation, 15° internal rotation, 20° dorsiflexion, and 20° plantarflexion. An automated three-dimensional measurement protocol was used to assess clear space (diastasis), translational angle (rotation), and vertical offset (fibular shortening) in each foot position and loading condition. Foot positioning had a significant effect on DTFJ configuration. Largest effects were related to clear space increase by 0.46 mm (SD 0.21 mm) in loaded dorsal flexion and translation angle of 2.36° (SD 1.03°) in loaded external rotation, both versus loaded neutral position. Loading had no effect on clear space and vertical offset in any position. Translation angle was significantly influenced under loading by − 0.81° (SD 0.69°) in internal rotation only. Foot positioning noticeably influences the measurements when evaluating DTFJ configuration. Loading seems to have no relevant effect on native ankles in neutral position.

21 May 2020 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
AAAnnette B. Ahrberg
Annette B. Ahrberg
RHRobert Hennings
Robert Hennings
NDNikolaus von Dercks
Nikolaus von Dercks
PHPierre Hepp
Pierre Hepp
CJChristoph Josten
Christoph Josten
USUlrich J. Spiegl
Ulrich J. Spiegl

2 November 2024 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
FSFiras Souleiman
Firas Souleiman
MHMartin Heilemann
Martin Heilemann
Georg OsterhoffGeorg Osterhoff
Georg Osterhoff
PHPierre Hepp
Pierre Hepp
Boyko GueorguievBoyko Gueorguiev
Boyko Gueorguiev
RHRobert Hennings
Robert Hennings
Background: The aim of this study was to identify the most responsive foot position for detection of isolated unstable syndesmotic injury. Methods: Fourteen paired human cadaveric lower legs were positioned in a pressure-controlled radiolucent frame and loaded under 700 N. Computed tomography scans were performed in neutral position, 15° internal / external rotation, and 20° dorsal / plantar flexion of the foot before and after cutting all syndesmotic ligaments. For each position, generated 3D models of the intact and injured distal tibiofibular joints were matched and analyzed by calculating three parameters: diastasis, anteroposterior displacement, and shortening of the fibula. Results: Transection of syndesmotic ligaments resulted in significant posterior translation of the fibula (4.34°, SD 1.63°, p < 0.01) compared to uninjured state for external rotation, significant anterior translation (-2.08°, SD 1.65°, p < 0.01) for internal rotation, and significant posterior translation (1.32°, SD 1.16°, p = 0.01) for dorsiflexion. Furthermore, the syndesmotic injury led to significantly increased clear space (0.46 mm, SD 0.46 mm, p = 0.03) in external rotation of the foot. Conclusion: External rotation of the foot under loading seems to be the most responsive position for detection of isolated syndesmotic instability. Under external rotational stress, anteroposterior instability and increased clear space resulting from a complete isolated unstable syndesmotic lesion were most evident.

7 August 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
RHRobert Hennings
Robert Hennings
USUlrich J. Spiegl
Ulrich J. Spiegl
CFCarolin Fuchs
Carolin Fuchs
PHPierre Hepp
Pierre Hepp
JFJohannes K. M. Fakler
Johannes K. M. Fakler
AAAnnette B. Ahrberg
Annette B. Ahrberg
Introduction: Incongruent stabilization of the distal tibiofibular joint (syndesmosis) results in poorer long-term outcome in malleolar fractures. The aim was to analyze whether the orientation of the syndesmotic stabilization would affect the immediate reduction imaged in computed tomography (CT). Materials and methods: The syndesmotic congruity in 114 ankle fractures with stabilization of the syndesmosis were retrospectively analyzed in the post-operative bilateral CT scans. The incisura device angle (IDA) was defined and correlated with the side-to-side difference of Leporjärvi clear-space (ΔLCS), anterior tibiofibular distance (ΔantTFD) and Nault talar dome angle (ΔNTDA) regardless of the stabilization technique and separately for suture button system and syndesmotic screw. Asymmetric reduction was defined as ΔLCS > 2 mm and |ΔantTFD|> 2 mm. Results: Regardless of the stabilization technique, no correlation between the IDA and the ΔLCS (r = 0.069), the ΔantTFD (r = 0.019) nor the ΔNTDA (r = 0.177) could be observed. There were no differences between suture button system and syndesmotic screw. Asymmetrical reduction was detected in 46% of the cases, while sagittal asymmetry was most common. No association was found between the orientation of stabilization device and occurrence of asymmetrical reduction (p > 0.05). The results of suture button system and syndesmotic screw were comparable in this respect (p > 0.05). Conclusion: Poor correlation between the orientation of the stabilization device and the immediate post-operative congruity of the syndesmosis could be shown. In contrast to current literature, this study did not show difference of suture button system over syndesmotic screw in this regard. Careful adjustment of the fibula in anteroposterior orientation should be given special attention.