Martin Heilemann

Martin Heilemann

Auto-generated profile, based on publicly available information

Martin Heilemann

Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Leipzig, Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
RHRobert Hennings
Robert Hennings
FSFiras Souleiman
Firas Souleiman
MHMartin Heilemann
Martin Heilemann
MHMareike Hennings
Mareike Hennings
AKAlexis Klengel
Alexis Klengel
AAAnnette B. Ahrberg
Annette B. Ahrberg
Background: Inadequate reduction of syndesmotic injuries can result in disabling clinical outcomes. The aim of the study was to compare syndesmosis congruity after fixation by syndesmotic screws (SYS) or a suture button system (SBS) using three-dimensional (3D) computed imaging techniques. Methods: In a retrospective single-center study, patients with unilateral stabilization of an ankle fracture with a syndesmotic injury and post-operative bilateral CT scans were analyzed using a recently established 3D method. The side-to-side differences were compared for tibio-fibular clear space (∆CS), translation angle (∆α), and vertical offset (∆z) among patients stabilized with syndesmotic screws or suture button system. Syndesmotic malreduction was defined for ∆CS > 2 mm and for |∆α| > 5°. ∆CS and ∆α were correlated with two-dimensional (2D) measurements. Results: Eighteen patients stabilized with a syndesmosis screw and 29 stabilized with a suture button system were analyzed. After stabilization, both groups revealed mild diastasis (SYS: mean ∆CS 0.3 mm, SD 1.1 mm vs SBS: mean ∆CS 0.2 mm, SD 1.2 mm, p = 0.710). In addition, both stabilization methods showed slight dorsalization of the fibula (SYS: mean ∆α 0.5°, SD 4.6° vs SBS: mean ∆α 2.1°, SD 3.7°, p = 0.192). Also, restoration of the fibula-to-tibia length ratio also did not differ between the two groups (SYS: mean Δz of 0.5 mm, SD 2.4 mm vs SBS: mean Δz of 0 mm, SD 1.2 mm; p = 0.477). Malreduction according to high ∆α was most common (26% of cases), with equal distribution between the groups (p = 0.234). ∆CS and ∆α showed good correlation with 2D measurements (ρ = 0.567; ρ = 0.671). Conclusion: This in vivo analysis of post-operative 3D models showed no differences in immediate post-operative alignment after syndesmotic screws or suture button system. Special attention should be paid to syndesmotic malreduction in the sagittal orientation of the fibula in relation to the tibia in radiological control of the syndesmotic congruity as well as intra-operatively.

7 June 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FSFiras Souleiman
Firas Souleiman
MHMartin Heilemann
Martin Heilemann
RHRobert Hennings
Robert Hennings
PHPierre Hepp
Pierre Hepp
Boyko GueorguievBoyko Gueorguiev
Boyko Gueorguiev
DGDominic Gehweiler
Dominic Gehweiler
The aim of this study was to investigate the effect of different loading scenarios and foot positions on the configuration of the distal tibiofibular joint (DTFJ). Fourteen paired human cadaveric lower legs were mounted in a loading frame. Computed tomography scans were obtained in unloaded state (75 N) and single-leg loaded stand (700 N) of each specimen in five foot positions: neutral, 15° external rotation, 15° internal rotation, 20° dorsiflexion, and 20° plantarflexion. An automated three-dimensional measurement protocol was used to assess clear space (diastasis), translational angle (rotation), and vertical offset (fibular shortening) in each foot position and loading condition. Foot positioning had a significant effect on DTFJ configuration. Largest effects were related to clear space increase by 0.46 mm (SD 0.21 mm) in loaded dorsal flexion and translation angle of 2.36° (SD 1.03°) in loaded external rotation, both versus loaded neutral position. Loading had no effect on clear space and vertical offset in any position. Translation angle was significantly influenced under loading by − 0.81° (SD 0.69°) in internal rotation only. Foot positioning noticeably influences the measurements when evaluating DTFJ configuration. Loading seems to have no relevant effect on native ankles in neutral position.

2 November 2024 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
FSFiras Souleiman
Firas Souleiman
MHMartin Heilemann
Martin Heilemann
Georg OsterhoffGeorg Osterhoff
Georg Osterhoff
PHPierre Hepp
Pierre Hepp
Boyko GueorguievBoyko Gueorguiev
Boyko Gueorguiev
RHRobert Hennings
Robert Hennings
Background: The aim of this study was to identify the most responsive foot position for detection of isolated unstable syndesmotic injury. Methods: Fourteen paired human cadaveric lower legs were positioned in a pressure-controlled radiolucent frame and loaded under 700 N. Computed tomography scans were performed in neutral position, 15° internal / external rotation, and 20° dorsal / plantar flexion of the foot before and after cutting all syndesmotic ligaments. For each position, generated 3D models of the intact and injured distal tibiofibular joints were matched and analyzed by calculating three parameters: diastasis, anteroposterior displacement, and shortening of the fibula. Results: Transection of syndesmotic ligaments resulted in significant posterior translation of the fibula (4.34°, SD 1.63°, p < 0.01) compared to uninjured state for external rotation, significant anterior translation (-2.08°, SD 1.65°, p < 0.01) for internal rotation, and significant posterior translation (1.32°, SD 1.16°, p = 0.01) for dorsiflexion. Furthermore, the syndesmotic injury led to significantly increased clear space (0.46 mm, SD 0.46 mm, p = 0.03) in external rotation of the foot. Conclusion: External rotation of the foot under loading seems to be the most responsive position for detection of isolated syndesmotic instability. Under external rotational stress, anteroposterior instability and increased clear space resulting from a complete isolated unstable syndesmotic lesion were most evident.