This study investigates the effect of delay in compaction on the optimum moisture content and the mechanical propertie s (i.e., compressive strength, ultrasonic pulse velocity, splitting tensile strength, and modulus of elasticity) of roller-compacted concrete pavement (RCCP) made of electric arc furnace (EAF) slag aggregate. EAF slag with size in the range of 4.75–19 mm was used to replace natural coarse aggregate in RCCP mixtures. A new mixing method was proposed for RCCP using EAF slag aggregate. The optimum moisture content of RCCP mixtures in this study was determined by a soil compaction method. The Proctor test assessed the optimum moisture content of mixtures at various time after mixing completion (i.e., 0, 15, 30, 60, and 90 min). Then, the effect of delay in compaction on the mechanical properties of RCCP mixtures at 28 days of age containing EAF slag aggregate was studied. The results presented that the negative effect on water content in the mixture caused by the higher water absorption characteristic of EAF slag was mitigated by the new mixing method. The optimum water content and maximum dry density of RCCP experience almost no effect from the delay in compaction. The compressive strength and splitting tensile strength of RCCP using EAF slag aggregate fulfilled the strength requirements for pavement with 90 min of delay in compaction.
19 July 2018 in IOP Conference Series: Earth and Environmental Science
The aim of this study is to investigate the effect of factors in mixing proportion on the dry density of Roller-compacted concrete pavement made of EAF slag aggregate and fly ash by using Taguchi method. In this study, EAF slag with size in range of 4.75 – 19 mm was used as a substitute for natural coarse aggregate with three percentages (i.e. 0%, 50% and 100%). Cement was partially replaced by fly ash at three content levels (i.e. 0%, 20% and 40%). Four factors are considered to study including the percentage of EAF slag aggregate, the percentage of binder (cement + fly ash), the fly ash ratio, and the moisture content. And, three levels of four factors were proposed to study the influence of them on the dry density of RCCP. Thus, nine mixtures conforming the orthogonal array L9 of Taguchi method were prepared to determine the dry density of RCCP by Proctor test. The results were assessed by the analysis of variance (ANOVA). The results of this research indicated that increasing of the percentage of EAF slag as aggregate replacement led to rise the dry density, whereas increasing of the fly ash ratio as cement substitution resulted in the decrease of dry density. The percentage of binder is range of 10-14% and moisture content in range of 6-8% affected slightly on the dry density. When the moisture content exceeded 8% leading to the reduction of the dry density.