Recently, three‐dimensional (3D) printing has become increasingly popular in the medical sector for the production of anatomical biomodels, surgical guides, and prosthetics. With the availability of low‐cost desktop 3D printers and affordable materials, the in‐house or point‐of‐care manufacturing of biomodels and Class II medical devices has gained considerable attention in personalized medicine. Another projected development in medical 3D printing for personalized treatment is the in‐house production of patient‐specific implants (PSIs) for partial and total bone replacements made of medical‐grade material such as polyetheretherketone (PEEK). We present the first in‐hospital 3D printed scaphoid prosthesis using medical‐grade PEEK with fused filament fabrication (FFF) 3D printing technology.
Background: Numerous anatomical features of the first carpometacarpal (CMC I) joint have been investigated as potential predispositions for CMC I osteoarthritis (OA). Even though load transmission through the CMC I joint—and, therefore, the development of osteoarthritis—is believed to be influenced by the geometry of the first metacarpal (MC I) bone, there is no common definition of the MC I axes. Methods: CT scans of twenty healthy volunteers and pre- and postoperative CT scans of six patients with CMC I OA undergoing Wilson osteotomy were analyzed. We proposed a calculation method based on anatomical landmarks for the proximal joint surface axis (PA) angle and the definition of an anatomical (AA) and a mechanical (MA) longitudinal axis. We hypothesized that for an MC I extension osteotomy to be effective, the AA and MA need to be aligned surgically. Results: To align AA and MA, an average correction angle of 22.60° (SD 2.53°) at 1 cm and 26.73° (SD 2.55°) at 1.5 cm distal to the CMC I joint line is required. Conclusions: The hereby proposed method for patient-specific calculation of the correction can be used to improve the surgical technique.
Background/Objectives: Orthopedic implant infections are rare but represent a significant problem for patients, surgeons, and the healthcare systems. This is because these infections cause severe and persistent pain and, in some cases, may require revision of the implant, among other things. Thus, there is strong interest in the use of antimicrobial coatings on orthopedic implants. Here, we investigate electrochemically deposited Ca(OH)2 antimicrobial coating for its potential to be used on metallic orthopedic implants. Methods: A triphenyl tetrazolim chloride (TTC) assay and isothermal microcalorimetry (IMC) were used to determine the reduction in microbial activity on three sets of Ti parts (discs and screws): uncoated, coated with hydroxyapatite (HA), and coated with Ca(OH)2. Results: Using the TTC assay, a ~70% reduction in the growth of bacteria on Ca(OH)2-coated discs was found, and using IMC, bacterial growth on these discs showed a decreased rate and an increased lag phase up to 25 h. Each of these sets of results was statistically superior to the corresponding results obtained using the other sets of parts. Conclusions: The present results suggest that the Ca(OH)2 coating may have potential for use on metallic orthopedic implants.