Philipp Honigmann

Dr. Philipp Honigmann

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
PHPhilipp Honigmann
Philipp Honigmann
Neha SharmaNeha Sharma
Neha Sharma
BOBrando Okolo
Brando Okolo
UPUwe Popp
Uwe Popp
BMBilal Msallem
Bilal Msallem
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Additive manufacturing (AM) is rapidly gaining acceptance in the healthcare sector. Three-dimensional (3D) virtual surgical planning, fabrication of anatomical models, and patient-specific implants (PSI) are well-established processes in the surgical fields. Polyetheretherketone (PEEK) has been used, mainly in the reconstructive surgeries as a reliable alternative to other alloplastic materials for the fabrication of PSI. Recently, it has become possible to fabricate PEEK PSI with Fused Filament Fabrication (FFF) technology. 3D printing of PEEK using FFF allows construction of almost any complex design geometry, which cannot be manufactured using other technologies. In this study, we fabricated various PEEK PSI by FFF 3D printer in an effort to check the feasibility of manufacturing PEEK with 3D printing. Based on these preliminary results, PEEK can be successfully used as an appropriate biomaterial to reconstruct the surgical defects in a “biomimetic” design.

Verified
Journal Article
Open access
PDF file
Neha SharmaNeha Sharma
Neha Sharma
SASoheila Aghlmandi
Soheila Aghlmandi
FDFederico Dalcanale
Federico Dalcanale
Daniel SeilerDaniel Seiler
Daniel Seiler
HZHans-Florian Zeilhofer
Hans-Florian Zeilhofer
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Recent advancements in medical imaging, virtual surgical planning (VSP), and three-dimensional (3D) printing have potentially changed how today’s craniomaxillofacial surgeons use patient information for customized treatments. Over the years, polyetheretherketone (PEEK) has emerged as the biomaterial of choice to reconstruct craniofacial defects. With advancements in additive manufacturing (AM) systems, prospects for the point-of-care (POC) 3D printing of PEEK patient-specific implants (PSIs) have emerged. Consequently, investigating the clinical reliability of POC-manufactured PEEK implants has become a necessary endeavor. Therefore, this paper aims to provide a quantitative assessment of POC-manufactured, 3D-printed PEEK PSIs for cranial reconstruction through characterization of the geometrical, morphological, and biomechanical aspects of the in-hospital 3D-printed PEEK cranial implants. The study results revealed that the printed customized cranial implants had high dimensional accuracy and repeatability, displaying clinically acceptable morphologic similarity concerning fit and contours continuity. From a biomechanical standpoint, it was noticed that the tested implants had variable peak load values with discrete fracture patterns and failed at a mean (SD) peak load of 798.38 ± 211.45 N. In conclusion, the results of this preclinical study are in line with cranial implant expectations; however, specific attributes have scope for further improvements.

Verified
Journal Article
Open access
PDF file
Neha SharmaNeha Sharma
Neha Sharma
SCShuaishuai Cao
Shuaishuai Cao
BMBilal Msallem
Bilal Msallem
CKChristoph Kunz
Christoph Kunz
PBPhilipp Brantner
Philipp Brantner
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Computer-assisted surgery with three-dimensional (3D) printed surgical guides provides more accurate results than free-hand surgery. Steam sterilization could be one of the factors that affect the dimensions of surgical guide resin materials, leading to inaccuracies during surgeries. The purpose of this study was to evaluate the effects of steam sterilization on the dimensional accuracy of indication-specific hollow cube test bodies, manufactured in-house using Class IIa biocompatible resin materials (proprietary and third-party). To evaluate the pre- and post-sterilization dimensional accuracy, root mean square (RMS) values were calculated. The results indicate that, in all the groups, steam sterilization resulted in an overall linear expansion of the photopolymeric resin material, with an increase in outer dimensions and a decrease in inner dimensions. The effects on the dimensional accuracy of test bodies were not statistically significant in all the groups, except PolyJet Glossy (p > 0.05). The overall pre- and post-sterilization RMS values were below 100 and 200 µm, respectively. The highest accuracies were seen in proprietary resin materials, i.e., PolyJet Glossy and SLA-LT, in pre- and post-sterilization measurements, respectively. The dimensional accuracy of third-party resin materials, i.e., SLA-Luxa and SLA-NextDent, were within a comparable range as proprietary materials and can serve as an economical alternative.

12 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
PHPhilipp Honigmann
Philipp Honigmann
Neha SharmaNeha Sharma
Neha Sharma
RSRalf Schumacher
Ralf Schumacher
JRJasmine Rueegg
Jasmine Rueegg
MHMathias Häfeli
Mathias Häfeli
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Recently, three‐dimensional (3D) printing has become increasingly popular in the medical sector for the production of anatomical biomodels, surgical guides, and prosthetics. With the availability of low‐cost desktop 3D printers and affordable materials, the in‐house or point‐of‐care manufacturing of biomodels and Class II medical devices has gained considerable attention in personalized medicine. Another projected development in medical 3D printing for personalized treatment is the in‐house production of patient‐specific implants (PSIs) for partial and total bone replacements made of medical‐grade material such as polyetheretherketone (PEEK). We present the first in‐hospital 3D printed scaphoid prosthesis using medical‐grade PEEK with fused filament fabrication (FFF) 3D printing technology.

31 August 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Neha SharmaNeha Sharma
Neha Sharma
SASoheila Aghlmandi
Soheila Aghlmandi
SCShuaishuai Cao
Shuaishuai Cao
CKChristoph Kunz
Christoph Kunz
PHPhilipp Honigmann
Philipp Honigmann
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Additive manufacturing (AM) of patient-specific implants (PSIs) is gradually moving towards in-house or point-of-care (POC) manufacturing. Polyetheretherketone (PEEK) has been used in cranioplasty cases as a reliable alternative to other alloplastic materials. As only a few fused filament fabrication (FFF) printers are suitable for in-house manufacturing, the quality characteristics of the implants fabricated by FFF technology are still under investigated. This paper aimed to investigate PEEK PSIs fabricated in-house for craniofacial reconstruction, discussing the key challenges during the FFF printing process. Two exemplary cases of class III (Group 1) and class IV (Group 2) craniofacial defects were selected for the fabrication of PEEK PSIs. Taguchi’s L9 orthogonal array was selected for the following nonthermal printing process parameters, i.e., layer thickness, infill rate, number of shells, and infill pattern, and an assessment of the dimensional accuracy of the fabricated implants was made. The root mean square (RMS) values revealed higher deviations in Group 1 PSIs (0.790 mm) compared to Group 2 PSIs (0.241 mm). Horizontal lines, or the characteristic FFF stair-stepping effect, were more perceptible across the surface of Group 1 PSIs. Although Group 2 PSIs revealed no discoloration, Group 1 PSIs displayed different zones of crystallinity. These results suggest that the dimensional accuracy of PSIs were within the clinically acceptable range; however, attention must be paid towards a requirement of optimum thermal management during the printing process to fabricate implants of uniform crystallinity.

1 March 2016 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
PHPhilipp Honigmann
Philipp Honigmann
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
RSRegula Steiger
Regula Steiger
MHMathias Haefeli
Mathias Haefeli
RSRalf Schumacher
Ralf Schumacher
JHJulia Henning
Julia Henning