Emilio A. Torres-Netto

Dr. Emilio A. Torres-Netto


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2019 in Cornea
Verified
Journal Article
Closed access
PLPaul Z. Lang
Paul Z. Lang
NHNikki L. Hafezi
Nikki L. Hafezi
SKSumitra S. Khandelwal
Sumitra S. Khandelwal
ETEmilio A. Torres-Netto
Emilio A. Torres-Netto
FHFarhad Hafezi
Farhad Hafezi
JRJ. Bradley Randleman
J. Bradley Randleman
Purpose: To compare the relative 12-month corneal crosslinking (CXL) functional outcomes using standard protocol and accelerated protocols in patients with progressive keratoconus. Methods: CXL was performed using 3 epithelium-off protocols: standard [3 mW/cm2 for 30 minutes, 5.4 J/cm2 (S3/30-CXL)], accelerated with equivalent total irradiance [9 mW/cm2 for 10 minutes, 5.4 J/cm2 (A9/10-CXL)], and accelerated with increased total irradiance [30 mW/cm2 for 4 minutes, 7.2 J/cm2 (A30/4-CXL)]. Efficacy measurements were evaluated 12 months after treatment with Scheimpflug imaging (Pentacam HR) and included change in maximum keratometry (K Max), corrected distance visual acuity (CDVA), other keratometric variables, pachymetry, keratoconus indices, astigmatism, asphericity, manifest refraction, and higher order aberrations. Results: Ninety-three eyes (67 patients) were evaluated: 35 eyes (26 patients) with S3/30-CXL, 29 eyes (19 patients) with A9/10-CXL, and 29 eyes (22 patients) with A30/4-CXL. Mean ∆K Max was −1.53 ± 2.1 diopter (D) for S3/30-CXL, −0.71 ± 1.3 D for A9/10-CXL, and −0.70 ± 2.3 D for A30/4-CXL (P = 0.37). Mean ∆CDVA(logMAR) was −0.18 ± 0.2 for S3/30-CXL, −0.13 ± 0.2 for A9/10-CXL, and −0.18 ± 0.2 for A30/4-CXL (P = 0.79). ∆K Mean (r = −0.29 to −0.46), anterior asphericity (r = −0.34 to −0.40), and central keratoconus index (r = −0.18 to −0.38) best correlated with ∆CDVA. S3/30-CXL had greater changes in index of surface variance, index of vertical asymmetry, keratoconus index, and regularization index compared to A9/10-CXL and A30/4-CXL. There were no other differences between protocols. Conclusions: All 3 protocols showed improvements in K Max, CDVA, and other variables, with similar functional outcomes for each despite greater change in keratoconus indices after S3/30-CXL. Correlations between change in measured variables and CDVA were poor overall; however, K Mean, central keratoconus index, and anterior asphericity were better correlated with CDVA than K Max.

15 April 2020 in Cornea
Verified
Journal Article
Closed access
SKSabine Kling
Sabine Kling
FHFong Siang Hufschmid
Fong Siang Hufschmid
ETEmilio A. Torres-Netto
Emilio A. Torres-Netto
JRJ. Bradley Randleman
J. Bradley Randleman
MWMark Willcox
Mark Willcox
FHFarhad MD Hafezi
Farhad MD Hafezi
Purpose: Photoactivated chromophore for keratitis cross-linking (PACK-CXL) is used as an adjunct therapy to antibiotic medication in infectious keratitis. This experimental study aimed at quantifying the PACK-CXL efficacy as a function of UV fluence using several bacterial strains and irradiated volumes.Methods: Six distinct bacterial strains, including standardized strains and clinically isolated strains from patients with keratitis, were analyzed. Bacterial concentrations between 102and 108cells/mL were used (simulating small corneal ulcers). Volumes of either 11 μL (≈285 μm stromal thickness) or 40 μL (≈1000 μm stromal thickness) were irradiated within a microtiter plate at different fluences (5.4–27 J/cm2) and irradiances (3, 9 and 18 mW/cm2). The ratio of bacterial killing (B†) was determined to evaluate the antimicrobial efficacy of PACK-CXL.Results: B† was similar (51 ± 11%) in bacterial concentrations between 103and 105per ml. In 11 μL volume,Staphylococcus aureus(SA) 8325-4 ATCC 29213,Bacillus subtilis(BS) 212901, andPseudomonas aeruginosa(PA) 2016-866624 were most sensitive to PACK-CXL at 5.4 J/cm2(on average B† = 49 ± 8%), whereasKlebsiella oxytoca(KO) 2016-86624 (B† = 25%) was least sensitive. When irradiating a larger volume, B† was on average lower in 40 μL (19 ± 18%), compared with 11 μL (45 ± 17%,P< 0.001). By contrast, applying a higher UV fluence increased B† of SA ATCC 29213, from 50% at 5.4 J/cm2to 92% at 10.8 J/cm2, to 100% at 16.2 J/cm2and above.Conclusions: Applying higher UV fluences substantially increases the bacterial killing rates. Safety limits for clinical application require further investigation.

1 November 2018 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
ETEmilio A. Torres-Netto
Emilio A. Torres-Netto
SKSabine Kling
Sabine Kling
NHNikki Hafezi
Nikki Hafezi
PVPaolo Vinciguerra
Paolo Vinciguerra
JRJ. Bradley Randleman
J. Bradley Randleman
FHFarhad Hafezi
Farhad Hafezi
PURPOSE: To evaluate the impact of varying treatment time on the efficacy of iontophoresis-assisted transepithelial corneal cross-linking (I-CXL) in ex vivo porcine corneas. METHODS: One hundred twelve porcine corneas with intact epithelium were divided into 7 groups and analyzed. Groups 1, 2, and 3 received standard epitheliumoff CXL (S-CXL) with hypo-osmolaric 0.1% riboflavin and 30 minutes of ultraviolet-A (UV-A) irradiation at 3 mW/cm 2 , 10 minutes at 9 mW/cm 2 , or were not irradiated (controls). Groups 4, 5, 6, and 7 received I-CXL for either 60 minutes at 1.5 mW/cm 2 , 30 minutes at 3 mW/cm 2 , 10 minutes at 9 mW/cm 2 , or were not irradiated (controls). Elastic modulus and stress after relaxation of 5-mm wide corneal strips were analyzed. RESULTS: In the S-CXL groups, significant differences ( P ≤ .05) in stress-strain extensometry were found between controls and 3 mW/cm 2 for 30 minutes (group 1) and between controls and 9 mW/cm 2 for 10 minutes (group 2). In the I-CXL groups, only the 1.5 mW/cm 2 for 60 minutes setting (group 4) showed a significant stiffening effect. All epithelium-off groups provided a stiffening effect significantly stronger than I-CXL: with a stiffening effect of 149% and 112%, groups 1 and 4 were the groups with greater elastic modulus between the S-CXL and I-CXL groups, respectively. CONCLUSIONS: The biomechanical effect of I-CXL increased significantly when using a low irradiance/long irradiation setting. Oxygen diffusion thus represents a limiting factor even when riboflavin penetration is improved via iontophoresis. Still less effective than S-CXL, this modification may help establish transepithelial CXL as a treatment option in selected cases. [ J Refract Surg . 2018;34(11):768–774.]

22 July 2020 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
Farhad HafeziFarhad Hafezi
Farhad Hafezi
NHNikki L. Hafezi
Nikki L. Hafezi
BPBojan Pajic
Bojan Pajic
FGFrancesca Gilardoni
Francesca Gilardoni
JRJ. Bradley Randleman
J. Bradley Randleman
ETEmilio A. Torres-Netto
Emilio A. Torres-Netto
Background: To determine the average amount of mechanical forces applied to the lids of keratoconus patients during eye rubbing. Methods: Fifty-seven patients (41 male, 16 female, average age 34.8 years) with a clinically and topographically diagnosed keratoconus and a history of eye rubbing were prospectively asked to perform their individual eye rubbing movement on a high-precision balance. The type of eye-rubbing movement and the force applied, represented in newtons (N), were recorded and analyzed. Results: We detected three different types of eye rubbing. Rubbing with the fingertip was most frequent (51%), followed by rubbing with the knuckle (44%) and rubbing with the fingernail (6%). Each type of eye rubbing showed different average forces, with knuckle type eye rubbing applying significantly more force (9.6 ± 6.3 N) on the lids than fingertip (4.3 ± 3.1 N) and fingernail (2.6 ± 3.3 N) types (p < 0,001 and p = 0,016, respectively). Conclusions: There were major variations in the force exerted on the lids, depending on the type of eye rubbing employed. This data will help determine the forces that need to be applied in future experimental eye rubbing models.

1 April 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
BKBoris Knyazer
Boris Knyazer
YKYonit Krakauer
Yonit Krakauer
MTMuhammad Abu Tailakh
Muhammad Abu Tailakh
AAAsaf Achiron
Asaf Achiron
IHIdan Hecht
Idan Hecht
FHFarhad Hafezi
Farhad Hafezi
PURPOSE: To compare the outcomes of accelerated photoactivated chromophore for keratitis corneal cross-linking (PACK-CXL) as an adjunct treatment for bacterial keratitis (PACK-CXL plus standard antibiotic therapy) for patients receiving only standard antibiotic therapy. METHODS: Retrospective cohort study of outcomes of patients with moderate infectious presumed bacterial keratitis (ulcer diameter 2 to 7 mm and stromal depth < 300 µm) were compared before and after initiation of a new treatment protocol of PACK-CXL in addition to standard antibiotic treatment. RESULTS: A total of 70 eyes of 70 patients were included: 39 eyes in the PACK-CXL plus antibiotic (PACK-ABX) group and 31 eyes in the antibiotic only (ABX) control group. The PACK-ABX group showed shorter times to complete reepithelialization (9.3 ± 6.0 vs 16.0 ± 12.7 days, P = .01) and did not require tectonic emergency keratoplasty (0% versus 19.4%, P = .006). The PACK-ABX group also showed a higher percentage of eyes with complete reepithelialization in 6 days or less (46.2% vs 6.5%, P < .001) and a trend for shorter hospitalizations (6.3 ± 5.0 vs 8.5 ± 4.5 days, P = .06). A multivariate analysis controlling for age showed that PACK-ABX treatment remained significantly associated with early ulcer reepithelialization (odds ratio = 0.09, 95% confidence interval = 0.02 to 0.48, P = .005). CONCLUSIONS: This study validates previous findings regarding the use of accelerated PACK-CXL in the treatment of bacterial keratitis. Adding PACK-CXL improved clinical outcomes (reducing healing time) when compared to antibiotics alone. [ J Refract Surg . 2020;36(4):258–264.]

3 June 2020 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
SKSabine Kling
Sabine Kling
ETEmilio A. Torres-Netto
Emilio A. Torres-Netto
BSBogdan Spiru
Bogdan Spiru
WSWalter Sekundo
Walter Sekundo
FHFarhad Hafezi
Farhad Hafezi
Purpose: Quasi-static optical coherence elastography (OCE) is an emerging technology to investigate corneal biomechanical behavior in situations similar to physiological stress conditions. Herein OCE was applied to evaluate previously inaccessible biomechanical characteristics of human corneal tissue and to study the role of Bowman's layer in corneal biomechanics. Methods: Human corneal donor buttons (n = 23) were obtained and Descemet's membrane and endothelium were removed. In 11 corneas, Bowman's layer was ablated by a 20 µm stromal excimer laser ablation. Buttons were mounted on an artificial anterior chamber and subjected to a pressure modulation from 10 to 30 mm Hg, and back to 10 mm Hg, in steps of 1 mm Hg. At each step, a spectral-domain optical coherence tomography scan was obtained. Displacements were analyzed by optical flow tracking, and strain over the entire stromal depth was retrieved from the phase gradient of the complex interference signal. Results: During pressure increase, corneal tissue moved upward (486–585 nm/mm Hg) but did not fully recover (Δ= 2.63 to 8.64 µm) after pressure decrease. Vertical corneal strain distribution was negative in the anterior and positive in the posterior cornea, indicating simultaneous corneal compression and expansion, respectively. Bowman's layer caused minor localized differences in corneal strain distribution. Conclusions: Corneal strain distribution is more complex than previously assumed, with a fundamental difference in mechanical response between the anterior and posterior stroma. Clinically, OCE technology might be used to monitor the progression of corneal ectatic diseases and to determine the success of corneal cross-linking.