Sabine Kling

Dr. Sabine Kling

Department Information Technology and Electrical Engineering, ETH Zurich
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2017 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
SKSabine Kling
Sabine Kling
FHFarhad Hafezi
Farhad Hafezi

1 December 2015 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
SKSabine Kling
Sabine Kling
OROlivier Richoz
Olivier Richoz
AHArthur Hammer
Arthur Hammer
DTDavid Tabibian
David Tabibian
SJSoosan Jacob
Soosan Jacob
FHFarhad Hafezi
Farhad Hafezi
PURPOSE: To compare the currently available ultraviolet-A (UV-A) corneal cross-linking (CXL) treatment protocols for thin corneas with respect to oxygen, UV fluence, and osmotic pressure. METHODS: Freshly enucleated murine (n = 16) and porcine (n = 16) eyes were used. The dependency on oxygen and the amount of UV absorption were evaluated using different CXL protocols, including standard CXL, contact lens-assisted CXL (caCXL), and CXL after corneal swelling. The CXL protocol was adapted from the treatment parameters of the human cornea to fit the thickness of murine and porcine corneas. Immediately after CXL, the corneas were subjected to biomechanical testing, including preconditioning, stress relaxation at 0.6 MPa, and stress-strain extensiometry. A two-element Prony series was fitted to the relaxation curves for viscoelastic characterization. RESULTS: Standard CXL was most efficient; prior corneal swelling reduced the long-term modulus by 6% and caCXL by 15% to 20%. Oxygen reduction decreased the long-term modulus G∞ by 14% to 15% and the instantaneous modulus G 0 by 2% to 5%, and increased the short-term modulus G 2 by 22% to 31%. Reducing the amount of absorbed UV energy decreased the long-term modulus G∞ by 5% to 34%, the instantaneous modulus G 0 by 7% to 29%, and the short-term modulus G 2 by 17% to 20%. The amount of absorbed UV light was more important in porcine than in murine corneas. CONCLUSIONS: The higher oxygen availability in thin corneas potentially increases the overall efficacy of riboflavin UV-A CXL compared to corneas of standard thickness. Clinical protocols for thin corneas should be revised to implement these findings. [ J Refract Surg. 2015;31(12):840–846.]

1 January 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
SKSabine Kling
Sabine Kling
SMSusana Marcos
Susana Marcos
Purpose. Intrastromal corneal-ring segments (ICRSs) are applied to improve highly distorted vision in keratoconic, myopic, and astigmatic patients. Selections of ICRS geometry and position are primarily based on empirical nomograms. We developed a finite-element model (FEM) predicting the corneal response to different ICRS geometries in normal and keratoconic corneas. Methods. A two-dimensional FEM was built in proprietary software (ANSYS-APDL), consisting of hyperelastic ocular tissues (cornea, limbus, sclera) and a triangular/hexagonal ICRS of poly(methyl methacrylate). An incrustation model was developed considering the local material addition and rigidity increase at the ICRS position and also for the triangular ICRS the geometric difference between its base (plane) and corneal tunnel (parallel to corneal surface). Different ICRS heights (150–350 μm) and optical zones (4.4–6.6 mm) were simulated. An axis-symmetric model of keratoconus was studied, where corneal elasticity was decreased locally. Results. ICRS geometry (height and optical zone) had a significant influence on corneal power: changes from 4.08 to −17.7 diopters (D) (healthy)/3.31 to −20.5 D (keratoconic) were observed. Central corneal thickness was predicted to increase by up to 38.5 μm (healthy)/97.9 μm (keratoconic). Spherical aberration also changed upon ICRS implantation. The protrusion of the posterior cornea behind the rings was well predicted. The model confirmed the clinically reported trends on the effect of ring geometry. Conclusions. FEM is a powerful tool to study the corneal response to ICRS implantation. The combination of FEM with individual biomechanical properties and geometry of patients holds promise to increase the predictability of ICRS surgery.

22 January 2020 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
SKSabine Kling
Sabine Kling
The purpose of this study was to develop a novel non-contact optical coherence elastography (OCE) approach to measure laterally and axially highly resolved corneal strain distribution at different stages of patterned corneal cross-linking (CXL). Freshly enucleated rat eyes were obtained and prepared for accelerated patterned CXL treatment with distinct ultraviolet (UV) patterns (central, peripheral, bow-tie irradiation). Each cornea was measured repeatedly, in three different conditions: (i) virgin, (ii) after epithelial debridement and 0.5% hypo-osmolar riboflavin instillation for 30 min, and (iii) after patterned CXL at 9 mW cm −2 for 10 min. For biomechanical assessment, the corneal deformation response to an ambient pressure variation of −2 mmHg was recorded by OCE. Strain maps were obtained from phase and magnitude changes in the complex optical coherence tomography signal. Virgin corneas presented negative strain (−2.7 ± 1.1‰) in the anterior cornea and positive strain (1.9 ± 1.3‰) in the posterior cornea. A pronounced shift towards positive strains in the anterior cornea (particularly in UV-irradiated regions) was observed after CXL. Patterned UV irradiation induced localized strain alterations closely matching the geometry of the irradiation pattern. This study demonstrates the possibility of non-contact OCE by ambient pressure modulation, which could substantially improve the early diagnosis of corneal degeneration, advance research in small-animal eyes and refine in vitro mechanical investigation.

15 April 2020 in Cornea
Verified
Journal Article
Closed access
SKSabine Kling
Sabine Kling
FHFong Siang Hufschmid
Fong Siang Hufschmid
ETEmilio A. Torres-Netto
Emilio A. Torres-Netto
JRJ. Bradley Randleman
J. Bradley Randleman
MWMark Willcox
Mark Willcox
FHFarhad MD Hafezi
Farhad MD Hafezi
Purpose: Photoactivated chromophore for keratitis cross-linking (PACK-CXL) is used as an adjunct therapy to antibiotic medication in infectious keratitis. This experimental study aimed at quantifying the PACK-CXL efficacy as a function of UV fluence using several bacterial strains and irradiated volumes.Methods: Six distinct bacterial strains, including standardized strains and clinically isolated strains from patients with keratitis, were analyzed. Bacterial concentrations between 102and 108cells/mL were used (simulating small corneal ulcers). Volumes of either 11 μL (≈285 μm stromal thickness) or 40 μL (≈1000 μm stromal thickness) were irradiated within a microtiter plate at different fluences (5.4–27 J/cm2) and irradiances (3, 9 and 18 mW/cm2). The ratio of bacterial killing (B†) was determined to evaluate the antimicrobial efficacy of PACK-CXL.Results: B† was similar (51 ± 11%) in bacterial concentrations between 103and 105per ml. In 11 μL volume,Staphylococcus aureus(SA) 8325-4 ATCC 29213,Bacillus subtilis(BS) 212901, andPseudomonas aeruginosa(PA) 2016-866624 were most sensitive to PACK-CXL at 5.4 J/cm2(on average B† = 49 ± 8%), whereasKlebsiella oxytoca(KO) 2016-86624 (B† = 25%) was least sensitive. When irradiating a larger volume, B† was on average lower in 40 μL (19 ± 18%), compared with 11 μL (45 ± 17%,P< 0.001). By contrast, applying a higher UV fluence increased B† of SA ATCC 29213, from 50% at 5.4 J/cm2to 92% at 10.8 J/cm2, to 100% at 16.2 J/cm2and above.Conclusions: Applying higher UV fluences substantially increases the bacterial killing rates. Safety limits for clinical application require further investigation.

31 January 2020 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
SKSabine Kling
Sabine Kling
HKHossein Khodadadi
Hossein Khodadadi
OGOrcun Goksel
Orcun Goksel
Purpose: Optical coherence elastography (OCE) is a promising technique for high-resolution strain imaging in ocular tissues. A major strain-inducing factor in the eye is intraocular pressure (IOP), with diurnal physiological fluctuations reaching up to 5 mmHg. We study herein low-amplitude IOP modulation to assess local corneal strain patterns. Methods: Ex vivo porcine eye globes were adjusted to an initial IOP of 15 mmHg and subsequently 25 mmHg. Corneal strain was induced by two subsequent pressure cycles, in which IOP was first increased and then decreased, each by a total of 5 mmHg. Two-dimensional optical coherence tomography (2D-OCT) B-scans were recorded after each loading step. Axial strain maps were obtained from magnitude and phase changes and supra-pixel displacements from cross-correlation. The strain detection sensitivity was evaluated in an isotropic material. Results: Deformations arising from a single 1-mmHg step could be resolved. The largest strain amplitudes (5.11·10−3) were observed in the posterior stroma at a low initial IOP. Strain amplitude was 1.34 times higher at 15 mmHg than at 25 mmHg (p = 0.003). Upon IOP increase, the anterior cornea was compressed, whereas the posterior cornea showed axial expansion. Both morphological images and strain maps were sensitive to postmortem time. Strains that are larger than 2.44·10−5 could be reliably measured. Conclusions: Low-amplitude IOP modulation, similar to diurnal physiological changes, induced measurable deformations in corneal tissue. Axial strain maps permit a localized comparison of the corneal biomechanical response. Small-strain OCE can likely be extended to other domains.